Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0-25.4 mmWC
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0-25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC Specification

  • Grade
  • Industrial
  • Thread
  • 1/8 NPT
  • Display
  • Digital
  • Outer Size
  • Standard Compact
  • Seal Material
  • EPDM
  • Sensor Type
  • Differential Pressure Transmitter
  • Material
  • ABS, Polycarbonate
  • Dial Material
  • Digital
  • Pointer Material
  • Digital
  • Processing Type
  • Calibrated
  • Diameter
  • 80 mm
  • Glass Size
  • Standard
  • Mount Type
  • Wall or Panel
  • Scale Range
  • 0-25.4 mmWC
  • Accuracy
  • 1% of FS
  • Finishing
  • High Impact Polycarbonate Case
  • Measure Pressure Of
  • Air, Non-corrosive Gases
  • Accessories
  • Mounting Brackets, User Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Eastern Europe, Western Europe, Africa, Central America, Middle East, South America, Asia, North America, Australia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0-25.4 mmWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision in Air and Clean Gas Measurement

The DPT1-R8 transmitter is designed specifically for measuring differential pressure in dry, clean air and other non-corrosive gases. Its digital display and quick response allow for real-time monitoring, making it a trusted solution in HVAC systems, clean rooms, and laboratory applications.


Ease of Installation and Operation

Setup is simple with the compact design, barbed brass connections for secure tubing, and clearly marked screw terminals for electrical connections. Convenient push-button zero adjustment and mounting brackets enable fast deployment on wall or panel surfaces, with straightforward calibration out of the box.


Built Tough for Industrial Environments

Encased in high-impact polycarbonate and rated IP65, the DPT1-R8 withstands harsh environments, dust, and moisture. The robust electronic design supports stable readings under fluctuating conditions, while overpressure protection (2x full scale) adds operational security.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC:


Q: How do I install the Sensocon Series DPT1-R8 Pressure Transmitter?

A: Mount the DPT1-R8 on a wall or panel using the supplied brackets. Connect the barbed brass fittings to appropriate tubing for air or gas, and attach wires to the screw terminal for a 24V DC power supply and loop. Ensure the system is clean and free of contaminants for best results.

Q: What types of media can be measured with this transmitter?

A: The DPT1-R8 is designed to measure pressure of dry, clean air and non-corrosive gases. It is not suitable for liquid media or aggressive, corrosive chemicals, as this may damage internal components.

Q: When should the zero adjustment be performed?

A: Zero adjustment should be carried out during installation, after major maintenance, or anytime you observe a shift in baseline readings. Simply use the built-in push button when the transmitter is isolated from all pressure to recalibrate to zero.

Q: Where is this device commonly used?

A: This model is ideal for HVAC applications, clean room monitoring, filter and fan status indication, and process automation where precise, dynamic air pressure measurement is crucial. It sees frequent use in industrial, pharmaceutical, and laboratory environments.

Q: What benefits does the digital display provide?

A: The digital display allows for instant, clear readings of differential pressure, aiding quick troubleshooting and on-site calibration. Its readability enhances day-to-day operational efficiency and minimizes potential for manual interpretation errors.

Q: How does the DPT1-R8 ensure durability and reliability?

A: Its high-impact polycarbonate enclosure, IP65 ingress protection, and overpressure handling up to twice full scale safeguard internal electronics, making it suitable for harsh industrial environments and prolonged operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Seal Material : BunaN

Sensor Type : Differential Pressure Sensor

Accuracy : 1% of Full Scale

Scale Range : 0 10.0 inWC

Processing Type : Other, Electronic

Accessories : Mounting screws and manual included

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.25  mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.25 mbar

Seal Material : Silicone

Sensor Type : Differential Pressure Sensor

Accuracy : 1% of Full Scale

Scale Range : 0 0.25 mbar

Processing Type : Other, Electronic

Accessories : Mounting Screws, Instruction Manual

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -5.0 - 5.0 inWC

Seal Material : Silicone

Sensor Type : Differential Pressure Transmitter

Accuracy : 1.0% of Span

Scale Range : 5.0 to 5.0 inWC

Processing Type : Other, Electronic Sensor

Accessories : Bracket, Manual, Mounting Screws

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -2.5 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -2.5 - 2.5 inWC

Seal Material : EPDM

Sensor Type : Differential Pressure Sensor

Accuracy : 1.0% of FS

Scale Range : 2.5 to 2.5 inWC (Inches of Water Column)

Processing Type : Other, Electronic Signal Processing

Accessories : Mounting Screws, Installation Manual



Back to top