Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar Specification

  • Sensor Type
  • Differential Pressure Transmitter
  • Grade
  • Industrial
  • Seal Material
  • Silicone (for ports)
  • Display
  • Analog / Digital (based on selected model)
  • Outer Size
  • 115 mm x 90 mm x 57 mm (approx.)
  • Thread
  • 1/8 NPT
  • Material
  • ABS Plastic / Electronic Components
  • Dial Material
  • Polycarbonate (for models with display)
  • Processing Type
  • Pressure Sensing Electronic
  • Mount Type
  • Wall or panel mount
  • Scale Range
  • 0 - 0.62 mbar
  • Accuracy
  • 2% of full scale
  • Finishing
  • Textured enclosure with label
  • Measure Pressure Of
  • Air and Non-corrosive gases
  • Accessories
  • Mounting screws, installation instructions
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia, North America, Australia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precise Low-Pressure Measurement

The DPT1-R8 transmitter offers high-precision differential pressure monitoring with an accuracy of 2% of full scale, making it ideal for situations demanding reliable control, such as clean rooms and critical HVAC systems. Its fast response time ensures real-time feedback and efficiency.


Versatile Installation with Durable Build

Built from tough ABS plastic and featuring silicone-sealed ports, this transmitter is engineered for longevity in diverse conditions. It can be mounted on walls or panels and operates in any orientation, with IP54 protection for increased resilience.


Simple Operation and Maintenance

This device enables easy setup and calibration thanks to external push buttons for zero and span adjustment. The analog or digital display (model-dependent) and clear installation instructions further streamline its integration into existing systems.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar:


Q: How do I install the Sensocon DPT1-R8 differential pressure transmitter?

A: The DPT1-R8 can be wall or panel mounted using the included mounting screws. Its compact size and any-orientation capability make installation flexible. The electrical connection is completed via a screw terminal block for secure wiring.

Q: What applications are most suitable for the DPT1-R8 pressure transmitter?

A: This transmitter is ideal for HVAC systems, clean rooms, air flow measurement, and filter monitoring where accurate detection of low-pressure variations in air and non-corrosive gases is required.

Q: When should zero and span adjustments be performed on this transmitter?

A: Zero and span calibration should be carried out during initial installation and periodically as part of routine system maintenance. Adjustments are made simply using the external push buttons.

Q: Where can the DPT1-R8 be mounted within a facility?

A: With an IP54 rating and tolerance for a wide temperature and humidity range, the DPT1-R8 can be installed in various indoor locations, including control rooms, HVAC ductwork areas, and maintenance spaces, provided environmental limits are observed.

Q: What is the benefit of the 420 mA output signal provided by the DPT1-R8?

A: A 420 mA output ensures reliable transmission of measurement data over long distances with resistance to electrical interference, making it suitable for integration into most standard industrial control systems.

Q: How can I ensure optimal performance when using this transmitter?

A: To maintain accuracy, ensure that only air or compatible non-corrosive gases pass through the ports. Regularly check calibration and inspect for dust or condensation, and follow the installation instructions for best results.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 380 mmWC

Accessories : Mounting Bracket, User Manual

Sensor Type : Differential Pressure Transmitter

Finishing : Other, ABS Plastic with Smooth Finish

Grade : Industrial Grade

Seal Material : NBR (Nitrile Rubber)

Mount Type : Other, Wall Mount

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 508 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 508 mmWC

Accessories : Mounting Screws, Installation Manual

Sensor Type : Differential Pressure Transmitter

Finishing : Other, ABS Plastic Enclosure

Grade : Industrial Grade

Seal Material : Silicone

Mount Type : Other, Wall Mount

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -2500 - 2500 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -2500 - 2500 Pa

Accessories : Mounting bracket, screws, instruction manual

Sensor Type : Differential Pressure Sensor

Finishing : Other, Matte Finish

Grade : Industrial Grade

Seal Material : Silicone

Mount Type : Other, Wall Mount

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 2500 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 2500 Pa

Accessories : Mounting Screws, User Manual

Sensor Type : Differential Pressure Transmitter

Finishing : Other, ABS Plastic Enclosure

Grade : Industrial

Seal Material : Silicone

Mount Type : Other, Wall / Surface Mount



Back to top