MOQ : 12 Pieces

Dwyer USA Model 2150 Magnehelic Gage Range 0-150 Inch WC Specification

  • Sensor Type
  • Diaphragm
  • Grade
  • Industrial
  • Seal Material
  • Silicone diaphragm
  • Display
  • Analog
  • Outer Size
  • 4 inches (approximate diameter)
  • Thread
  • 1/8 NPT
  • Material
  • Die-cast aluminum housing
  • Dial Material
  • Acrylic
  • Pointer Material
  • Plastic
  • Processing Type
  • Precision-engineered
  • Diameter
  • 4 inches
  • Glass Size
  • 3-5/8 inches (viewing area)
  • Mount Type
  • Surface or flush mounting
  • Scale Range
  • 0-150 Inch WC
  • Accuracy
  • 2% of full scale
  • Finishing
  • Powder-coated die-cast aluminum case
  • Measure Pressure Of
  • Low air and non-corrosive gas differential pressure
  • Accessories
  • Mounting bracket, two 1/8 NPT plugs, three mounting screws, surface mounting hardware, and instruction sheet
 

Dwyer USA Model 2150 Magnehelic Gage Range 0-150 Inch WC Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Paypal, Cash Against Delivery (CAD), Telegraphic Transfer (T/T), Cheque, Cash Advance (CA)
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Africa, Central America, South America, Western Europe, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA Model 2150 Magnehelic Gage Range 0-150 Inch WC

Dwyer USA Model 2150 Magnehelic Gage Range 0-150 Inch WC

Dwyer 2150 Differential Pressure Gage, range 0-150" w.c. (inches of water), minor divisions 5.0.

Using Dwyer's simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Features

Bezel provides flange for flush mounting in panel.

Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Precision litho-printed scale is accurate and easy to read.

Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

Pointer stops of molded rubber prevent pointer over-travel without damage.

"Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.

O-ring seal for cover assures pressure integrity of case.



Superior Performance for Industrial Applications

Designed for reliability in challenging environments, the Model 2150 Magnehelic Gauge provides accurate differential pressure measurements for HVAC, air purity systems, and clean rooms. Its mechanical diaphragm sensor ensures immediate response without the need for power, while robust overpressure protection enhances safety. Suitable for both monitoring and system diagnostics, this gauge is precision-engineered for demanding, continuous-use scenarios.


Practical and Versatile Installation

With flexible mounting optionseither surface or flushthe 2150 Magnehelic Gauge adapts effortlessly to most setups. Each unit comes with a comprehensive accessory kit including mounting hardware and a clear instruction sheet, supporting seamless installation. The back and side connection locations and standard 1/8 NPT threads make integration straightforward for both new and retrofit applications.

FAQs of Dwyer USA Model 2150 Magnehelic Gage Range 0-150 Inch WC:


Q: How is the Model 2150 Magnehelic Gauge typically installed and what mounting options are available?

A: The Model 2150 Magnehelic Gauge offers straightforward installation, supporting both surface and flush mounting with the supplied bracket, plugs, mounting screws, and hardware. Connection ports are available on both the back and side, allowing easy integration into a variety of setups.

Q: What types of applications are best suited for the 2150 Magnehelic Gauge?

A: This gauge excels in applications that require monitoring of low differential pressures, such as HVAC airflow, clean room environments, air filter monitoring, and air velocity measurement. Its accuracy and durability make it an optimal choice for industrial, commercial, and laboratory uses.

Q: Where should the Magnehelic Gauge be located for optimal performance?

A: For best results, the gauge should be mounted in a dust-protected area within its operating temperature range (-20C to 60C). Proper placement ensures accurate readings, typically near air handling units, filters, or monitored enclosures like clean rooms.

Q: What is the process for zero adjustment and maintenance of the gauge?

A: Zero adjustment can be carried out easily via the external adjustment screw located on the front of the device, even after installation. Routine maintenance mainly involves keeping the acrylic window clean and ensuring ports remain unobstructed.

Q: When does the blowout plug provide overpressure protection and what benefit does this offer?

A: The built-in blowout plug protects the gauge by releasing pressure if internal differential pressures exceed its 15 psi (1.03 bar) maximum, preventing potential gauge or system damage. This enhances service life and safety.

Q: How does the analog display benefit users compared to digital alternatives?

A: The large 4-inch diameter analog scale offers immediate, at-a-glance readings without the need for power, making it particularly useful in situations where consistent visual monitoring and reliability are essential, especially during power outages.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

Price 4800 INR

Minimum Order Quantity : 12 Pieces

Glass Size : 4 inch dial window

Display : Analog pointer dial

Diameter : 4 inch (101.6 mm)

Processing Type : Other, Precision engineered

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Minimum Order Quantity : 12 Pieces

Glass Size : Acrylic glass lens, full face

Display : Analog, Circular Dial

Diameter : 168 mm (65/8)

Processing Type : Other, Factory calibrated, leak tested

Dwyer USA Model 2304 Magnehelic Gage Range 2-0-2 Inch WC

Dwyer USA Model 2304 Magnehelic Gage Range 2-0-2 Inch WC

Minimum Order Quantity : 12 Pieces

Glass Size : Clear acrylic

Display : Analog

Diameter : 4 inches

Processing Type : Other, Precision engineered

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Price 3400 INR

Minimum Order Quantity : 12 Pieces

Glass Size : Acrylic Lens, 91 mm Diameter

Display : Analog

Diameter : Gauge Face Diameter Approx. 91 mm (35/8 in)

Processing Type : Other, Precision Molded



Back to top