Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC
Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC
Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC
Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

MOQ : 12 Pieces

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC Specification

  • Bourdon Tube
  • Not applicable (diaphragm type)
  • Thread
  • 1/8 NPT
  • Outer Size
  • 4 inch diameter (approx.)
  • Display
  • Analog pointer dial
  • Grade
  • Industrial
  • Seal Material
  • Silicone rubber
  • Sensor Type
  • Mechanical diaphragm
  • Material
  • Die-cast aluminum housing, acrylic cover
  • Dial Material
  • Acrylic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Precision engineered
  • Diameter
  • 4 inch (101.6 mm)
  • Glass Size
  • 4 inch dial window
  • Mount Type
  • Surface or flush mount
  • Scale Range
  • 0-3.0 Inch WC (Water Column)
  • Accuracy
  • 2% of full scale
  • Finishing
  • Die-cast aluminum case, gray acrylic finish
  • Measure Pressure Of
  • Low air and non-corrosive gas pressure
  • Accessories
  • Two 1/8 NPT plugs, pipe mounting bracket, and screw pack (standard kit)
 

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC

Description

Dwyer 2003 Differential pressure gage, range 0-3.0" w.c. (inches of water), minor divisions .10.

Using Dwyers simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. Its inexpensive, too.

The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.


Features


Bezel provides flange for flush mounting in panel.

Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Precision litho-printed scale is accurate and easy to read.

Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

Pointer stops of molded rubber prevent pointer over-travel without damage.

"Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.

O-ring seal for cover assures pressure integrity of case.



Precision and Reliability for Industrial Applications

Engineered with a mechanical diaphragm sensor, the Dwyer 2003 Magnehelic Gage delivers high accuracy (2% of full scale) in measuring low pressure. Its durable die-cast aluminum construction and airtight acrylic cover ensure reliable performance even in demanding industrial environments.


Versatile Mounting and Easy Installation

The gage supports both surface and flush mounting, suiting a variety of installation settings. It comes equipped with two 1/8 NPT plugs, a pipe mounting bracket, and a screw pack, making setup efficient for new or replacement projects. Side and back connections provide flexibility during integration.


Ideal for Monitoring and Maintaining HVAC Systems

With a 03.0 inch WC scale and high-resolution analog display, this Magnehelic gage is perfectly suited for monitoring air filters, blower and fan pressures, and room or duct pressures. Its IP52 rating offers dust protection, aiding longevity in HVAC and air management applications.

FAQs of Dwyer USA 2003 Magnehelic Gage Range 0-3.0 Inch WC:


Q: How does the Dwyer 2003 Magnehelic Gage work to measure low pressure?

A: The Dwyer 2003 Magnehelic Gage uses a mechanical diaphragm sensor to detect small differences in low air or non-corrosive gas pressures and translates this movement to an analog pointer on a large, easy-to-read dial.

Q: What benefits does its external zero adjustment screw provide?

A: The external zero adjustment screw allows for quick and convenient recalibration of the gauge without disassembly, ensuring ongoing accuracy and minimizing downtime in your monitoring processes.

Q: When should I use the Dwyer 2003 Magnehelic Gage in my facility?

A: Use this gauge when you require precise low-pressure measurement in HVAC systems, filter monitoring, fan or blower pressure verification, or maintaining specified room and duct pressures.

Q: Where can the gauge be mounted or connected?

A: The Dwyer 2003 Magnehelic Gage supports both surface and flush mounting. It also features side and back 1/8 NPT connection ports, enabling flexible placement in different system setups.

Q: What process is involved in installing the Magnehelic Gage?

A: Installation involves connecting the pressure lines to the 1/8 NPT side or back ports, securing the gauge with the included mounting bracket and screws, and calibrating it via the external adjustment screw. The standard kit includes all necessary accessories for most setups.

Q: How does the Magnehelic Gage maintain accuracy and protection?

A: It maintains 2% full-scale accuracy and is built with a dust-protected IP52 enclosure. The die-cast aluminum housing and acrylic cover safeguard internal components from environmental stress and physical damage.

Q: What are the usage advantages for HVAC and industrial applications?

A: The gauge delivers reliable low-pressure readings crucial for monitoring air flow or filter status in HVAC systems, helping optimize equipment performance, reduce costly maintenance, and improve air quality control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer 2005D Magnehelic Differential Pressure Gauge

Dwyer 2005D Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Dial Material : Other, Acrylic

Scale Range : 00.5 inches w.c. (Water Column)

Outer Size : 4 inches (approx.)

Thread : 1/8 NPT Female

Measure Pressure Of : Other, Air and Noncorrosive Gases

Dwyer USA Model 2300-0 Magnehelic Gage Range 0.25-0-0.25 Inch WC

Dwyer USA Model 2300-0 Magnehelic Gage Range 0.25-0-0.25 Inch WC

Minimum Order Quantity : 12 Pieces

Dial Material : Other, White Aluminum with Black Marking

Scale Range : 0.2500.25 Inch WC (Water Column)

Outer Size : 4 inch (101.6 mm) Diameter

Thread : 1/8 NPT Female

Measure Pressure Of : Other, Air and NonCorrosive Gases

Dwyer 2215 Magnehelic Differential Pressure Gauge 0-15 PSI

Dwyer 2215 Magnehelic Differential Pressure Gauge 0-15 PSI

Minimum Order Quantity : 12 Pieces

Dial Material : Other, Acrylic

Scale Range : 015 PSI

Outer Size : 4 inches (nominal)

Thread : 1/8 NPT

Measure Pressure Of : Other, Air and Noncombustible Gases

Dwyer 2020D Magnehelic Differential Pressure Gauge

Dwyer 2020D Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Dial Material : Plastic

Scale Range : 00.5 to 060 in. H2O (varies by model; 2020D: 020 in. H2O)

Outer Size : 4 inch (101 mm) diameter case

Thread : 1/8 NPT

Measure Pressure Of : Other, Differential pressure of air and noncorrosive gases



Back to top