Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC
Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC
Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC
Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC
Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC
Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC

Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC

MOQ : 12 Pieces

Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC Specification

  • Outer Size
  • Approx. 4 inch Diameter
  • Seal Material
  • Silicone Rubber
  • Sensor Type
  • Diaphragm
  • Thread
  • No Thread (Panel Mount)
  • Display
  • Analog
  • Grade
  • Industrial
  • Material
  • Die-cast Aluminum Case
  • Dial Material
  • White Aluminum with Black Markings
  • Pointer Material
  • Black Aluminum
  • Processing Type
  • Precision Molded Case
  • Diameter
  • 4 inch (100 mm)
  • Glass Size
  • 4 inch (Viewing Area)
  • Mount Type
  • Surface / Panel Mount
  • Scale Range
  • 0-4.0 Inch WC (Water Column)
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Textured Black Finish (Bezel)
  • Measure Pressure Of
  • Low Differential Air and Non-corrosive Gases
  • Accessories
  • Two mounting brackets and screws, two 1/8 NPT plugs, one rubber tubing adapter, and instructions
 

Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Letter of Credit (L/C), Delivery Point (DP), Cash Against Delivery (CAD), Telegraphic Transfer (T/T), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC

Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC

Description

Dwyer 2004 Differential pressure gage, range 0-4.0" w.c. (inches of water), minor divisions .10.

Using Dwyers simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. Its inexpensive, too.

The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.


Features


Bezel provides flange for flush mounting in panel.

Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Precision litho-printed scale is accurate and easy to read.

Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

Pointer stops of molded rubber prevent pointer over-travel without damage.

"Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.

O-ring seal for cover assures pressure integrity of case.



Precision Measurement and Construction

Engineered for accuracy, the Dwyer 2004 Magnehelic Gage delivers 2% full-scale precision for monitoring low differential pressure. Its die-cast aluminum case with textured black bezel ensures durability, while a clear acrylic window and silicone rubber seals protect internal components. The vertical mounting orientation and external adjustment screw facilitate easy installation and calibration.


Versatile Applications in Industrial Settings

Ideal for diverse scenarios, this gauge excels in HVAC, cleanrooms, fan/blower pressure, and filter monitoring. Its compatibility with panel mounting, 1/8" NPT high/low pressure ports, and resistance to temperature extremes (from -7C to +60C) make it reliable for industrial, laboratory, and field use. All necessary accessories for installation are provided.

FAQs of Dwyer USA 2004 Magnehelic Gage Range 0-4.0 Inch WC:


Q: How can I install the Dwyer 2004 Magnehelic Gage?

A: The gauge is designed for surface or panel mounting. Accessories such as two mounting brackets, screws, and a tubing adapter are included for straightforward installation. Ensure vertical orientation for accurate readings and use the provided instructions for step-by-step guidance.

Q: What types of media can be measured with this gauge?

A: The Magnehelic 2004 is engineered to measure low differential pressure of air and non-corrosive gases only. It is not intended for use with liquids or corrosive gases.

Q: When should I perform zero adjustment on the gauge?

A: Zero adjustment should be carried out before initial use and periodically during routine maintenance. Use the external adjustment screw provided on the front of the gauge to calibrate the dial when no pressure is applied across the ports.

Q: Where can this differential pressure gauge be used?

A: Common applications include HVAC systems, cleanrooms, filter status monitoring, duct static pressure checks, fan and blower pressure measurement, differential pressure across orifice plates, and liquid level measurement in dry air systems.

Q: What benefits does the Dwyer 2004 Magnehelic Gage offer?

A: This industrial-grade gauge provides reliable and accurate analog pressure measurements. Its robust die-cast aluminum construction, RoHS compliance, and versatile application range ensure long service life and dependability in critical environments.

Q: How do I ensure accurate pressure readings with this instrument?

A: Mount the gauge vertically, use the 1/8" NPT high and low pressure ports correctly, and routinely check the zero adjustment. Keep the clear acrylic window clean and safeguard the instrument from overpressure exceeding 15 psig to maintain measurement accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer USA Model 2012 Magnehelic Gage Range 0-12 Inch WC

Dwyer USA Model 2012 Magnehelic Gage Range 0-12 Inch WC

Minimum Order Quantity : 12 Pieces

Glass Size : 4.75 inch (face diameter)

Dial Material : Other, Acrylic (clear lens)

Material : Other, Diecast Aluminum Case, Acrylic Lens

Accessories : Two 1/8 NPT plug, two surface mounting adapters, three mounting screws, and instruction sheet

Dwyer 2000-60PA Magnehelic Differential Pressure Gauge

Dwyer 2000-60PA Magnehelic Differential Pressure Gauge

Price 3400 INR

Minimum Order Quantity : 12 Pieces

Glass Size : Full view, approx. 100 mm

Dial Material : Other, Aluminum with PowderCoated Finish

Material : Other, Die Cast Aluminum Case

Accessories : Two 1/8 NPT plugs, two 1/8 NPT pipe thread to rubber tubing adapter, and three mounting adapters with screws

Dwyer 2010D Magnehelic Differential Pressure Gauge

Dwyer 2010D Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Glass Size : 4 inch (approx. 100 mm)

Dial Material : Other, Polycarbonate

Material : Other, Diecast Aluminum Case

Accessories : Mounting Screws, Two Static Pressure Tips with Tubing

Dwyer USA 2005 Magnehelic Gage Range 0-5.0 Inch WC

Dwyer USA 2005 Magnehelic Gage Range 0-5.0 Inch WC

Minimum Order Quantity : 12 Pieces

Glass Size : Full Size Front

Dial Material : Other, White Coated Aluminum

Material : Other, DieCast Aluminum Case

Accessories : Mounting Bracket, Two Static Pressure Tips, Two Tubing Pieces, Screws



Back to top