Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa
Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa
Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa
Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

MOQ : 12 Pieces

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa Specification

  • Grade
  • Industrial
  • Thread
  • No Thread (Panel Mount)
  • Seal Material
  • Silicone
  • Display
  • Analog
  • Sensor Type
  • Diaphragm
  • Outer Size
  • Approx. 109 mm (4-5/16 in) Square Front
  • Material
  • High Impact Plastic Case
  • Dial Material
  • Plastic
  • Pointer Material
  • Plastic
  • Processing Type
  • Precision Molded
  • Diameter
  • Gauge Face Diameter Approx. 91 mm (3-5/8 in)
  • Glass Size
  • Acrylic Lens, 91 mm Diameter
  • Mount Type
  • Panel Mount
  • Scale Range
  • 30-0-30 Pa
  • Accuracy
  • 2% Full Scale
  • Finishing
  • Gloss Black Front, Matte Case
  • Measure Pressure Of
  • Air and Compatible Gases
  • Accessories
  • 2 Static pressure tips with integral compression fittings, two 1/4 I.D. rubber tubing, and three mounting adapters with screws
 

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Domestic Market
  • All India
 

About Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa


Select the Magnehelic Gage for High Accuracy--Guaranteed within 2% of full scale--and for the wide choice of 81 Models Available to suit your needs precisely. Using Dwyer  Simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It"s inexpensive, too. The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment. Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale. Precision litho-printed scale is accurate and easy to read. Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft. Pointer stops of molded rubber prevent pointer over-travel without damage. "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft. Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid. Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale. Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration. Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures. Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting. OVERPRESSURE PROTECTION Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the Gage interior when over pressure reaches approximately 25 psig (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on Gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component. O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.



Robust and Accurate Pressure Measurement

The Dwyer 2300-60PA offers precise differential pressure readings, essential for maintaining environmental control in clean rooms and HVAC systems. Its accuracy of 2% full scale guarantees reliability, while the rugged, high-impact plastic housing ensures durability. The analog display enables rapid onsite reading and adjustments.


Easy Installation and Versatile Application

This pressure gage features a simple panel-mount design with all mounting adapters included. The supplied accessoriescompression fittings, rubber tubing, and static pressure tipsstreamline installation across various systems. Suited for filter, duct, or fan pressure monitoring, it can be deployed in industrial plants, laboratories, and commercial buildings.

FAQs of Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa:


Q: How can the Dwyer 2300-60PA Differential Pressure Gage be installed and adjusted?

A: The gauge is designed for panel mounting and requires the included mounting adapters and screws. For different setups, utilize the supplied static pressure tips and compression fittings. The external zero adjustment ensures the gauge is properly calibrated before use.

Q: What type of media can the Dwyer 2300-60PA measure?

A: This model is engineered to measure the pressure of air and compatible gases. It is not suitable for corrosive gases or liquids, ensuring dependable operation in standard HVAC or clean environment applications.

Q: When should the differential pressure gage be used?

A: Use the Dwyer 2300-60PA for applications requiring precise monitoring, such as filter loading, cleanroom pressure control, duct static pressure measurement, and fan performance assessment. It is suitable for continuous monitoring or periodic checks.

Q: Where is the ideal location to install the Dwyer 2300-60PA?

A: The gauge should be mounted in a visible and accessible location on a control panel or designated area in your monitoring system. Ensure the environment is within its operating temperature range of -7C to 60C (20F to 140F) to guarantee optimal performance.

Q: What benefits does the Dwyer 2300-60PA provide for industrial applications?

A: This pressure gauge allows early detection of pressure-related issues, such as clogged filters or improper airflow, helping reduce equipment downtime, improve energy efficiency, and maintain safe, clean environments.

Q: How does the overpressure protection work in this gauge?

A: The 2300-60PA is built to withstand overpressure up to its maximum rated value of 10 kPa without sustaining damage, providing peace of mind during critical operational fluctuations.

Q: What maintenance is required for the Dwyer 2300-60PA?

A: Regularly check the gauge for dust buildup or damage. Periodically verify zero calibration via the external adjustment and ensure silicone seals and tubing are intact to maintain accuracy and reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer 2204 Magnehelic Differential Pressure Gauge 0-4 PSI

Dwyer 2204 Magnehelic Differential Pressure Gauge 0-4 PSI

Minimum Order Quantity : 12 Pieces

Processing Type : Other, Machined and Assembled

Scale Range : 04 PSI

Accessories : Mounting Bracket (Included), Two 1/8 NPT Plugs, Three Mounting Adapters

Diameter : 4 inches (101.6 mm)

Grade : Industrial

Dwyer USA Model 2304 Magnehelic Gage Range 2-0-2 Inch WC

Dwyer USA Model 2304 Magnehelic Gage Range 2-0-2 Inch WC

Minimum Order Quantity : 12 Pieces

Processing Type : Other, Precision engineered

Scale Range : 202 Inch WC (Water Column)

Accessories : Two 1/8 NPT plugs, two 1/8 NPT to rubber tubing adapters, three mounting adapters, and screws

Diameter : 4 inches

Grade : Industrial

Dwyer 2000-60PA Magnehelic Differential Pressure Gauge

Dwyer 2000-60PA Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Processing Type : Other, Calibrated Mechanical

Scale Range : 060 Pa

Accessories : Two 1/8 NPT plugs, two 1/8 NPT pipe thread to rubber tubing adapter, and three mounting adapters with screws

Diameter : 4 inches (approx. 100 mm)

Grade : Industrial

Dwyer 2000-0AV Magnehelic Differential Pressure Gauge

Dwyer 2000-0AV Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Processing Type : Other, Factory calibrated

Scale Range : 00.2 inch w.c.

Accessories : Two 1/8 NPT plugs, two mounting screws, A610 flush mounting adapter (option)

Diameter : 4.75 inches (approx. 120 mm)

Grade : Industrial



Back to top