Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -0.5 - 0.5  inWC
Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -0.5 - 0.5  inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -0.5 - 0.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -0.5 - 0.5 inWC Specification

  • Thread
  • Push-on Ports (No Thread)
  • Grade
  • Industrial Grade
  • Display
  • Digital / No Local Display
  • Outer Size
  • 90 x 60 x 36 mm (H x W x D)
  • Sensor Type
  • Differential Pressure Transmitter
  • Seal Material
  • Silicone Rubber
  • Material
  • ABS Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount
  • Scale Range
  • -0.5 to 0.5 inWC
  • Accuracy
  • 1% of FS
  • Finishing
  • ABS Plastic Housing, Black Finish
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Screws, Instruction Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -0.5 - 0.5 inWC Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -0.5 - 0.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -0.5 - 0.5  inWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision Measurement for Critical Environments

The DPT10-R8 transmitter ensures highly accurate differential pressure readings (1% FS) within a narrow range, making it reliable for sensitive applications in air handling and industrial process control. Its electronic sensing technology and rapid response enhance control system performance.


Durable Build and Easy Installation

Constructed with an ABS plastic housing and a black finish, the DPT10-R8 boasts an IP54 protection class for durability in demanding environments. Wall-mountable and equipped with screw terminals, installation is straightforward and accessories like mounting screws and a manual are included.


User-Friendly Calibration and Operation

Zero and span adjustments are accessible via push buttons or a potentiometer, simplifying calibration. The transmitter operates seamlessly with both 24 VDC and 24 VAC, and offers clear digital indications, with or without a local display, fitting various operational setups.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -0.5 - 0.5 inWC:


Q: How do I install the Series DPT10-R8 Differential Pressure Transmitter?

A: The DPT10-R8 is designed for straightforward installation on a wall surface using the provided mounting screws. Electrical connections are made with screw terminals, and push-on ports allow easy connection to your pressure lines for air or non-corrosive gases.

Q: What is the benefit of the fast <1 second response time in this transmitter?

A: The under-one-second response time enables the transmitter to quickly detect and reflect any changes in differential pressure. This rapid feedback is essential in applications where prompt system adjustments are crucial for maintaining safety and optimal operation.

Q: When should I use this transmitter for pressure measurement?

A: Use the DPT10-R8 when you need accurate monitoring and control of low differential pressure in clean, dry air or non-aggressive gas environments, such as HVAC ducts, cleanrooms, or filter monitoring systems.

Q: What kind of media can the Series DPT10-R8 safely measure?

A: This transmitter is suitable for dry, clean air and non-corrosive (non-aggressive) gases only. It is not designed for use with liquid or corrosive gases to ensure measurement accuracy and prolong device life.

Q: How do I adjust the zero and span settings on the DPT10-R8?

A: Zero and span adjustments are conveniently handled through either onboard push buttons or a potentiometer. This feature enables easy recalibration, ensuring measurement precision throughout the transmitters use.

Q: Where is the best place to mount this transmitter for accurate readings?

A: For optimal performance, mount the unit on a stable wall near the point of measurement, away from sources of vibration, moisture, and direct exposure to corrosive gases. Following the included instruction manual ensures proper placement.

Q: What are the practical advantages of the devices industrial-grade ABS housing and IP54 protection?

A: The ABS plastic housing offers robustness and chemical resistance, while the IP54 protection means the transmitter is resistant to dust and splashes, making it dependable for industrial environments where operational reliability is crucial.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 25 mbar

Accuracy : 1% of full scale

Thread : ISO standard 1/8 NPT

Processing Type : Other, Electronic

Finishing : Other, Anodized Aluminum

Mount Type : Other, Panel / Surface Mount

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -5.0 - 5.0 inWC

Accuracy : 1.0% of Span

Thread : 1/8 NPT Female

Processing Type : Other, Electronic Sensor

Finishing : Other, Powder Coated

Mount Type : Other, Wall or Duct Mount

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 508 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 508 mmWC

Accuracy : 1% of Full Scale

Thread : 1/8 NPT Female

Processing Type : Other, Electronic

Finishing : Other, ABS Plastic Enclosure

Mount Type : Other, Wall Mount

Grade : Industrial Grade

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar

Accuracy : 2% of full scale

Thread : 1/8 NPT

Processing Type : Other, Pressure Sensing Electronic

Finishing : Other, Textured enclosure with label

Mount Type : Other, Wall or panel mount

Grade : Industrial



Back to top