Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 2.5 inWC
Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC Specification

  • Sensor Type
  • Differential Pressure Transmitter
  • Outer Size
  • 4.65 x 2.15 x 1.57 (approx.)
  • Display
  • No display (Analog Output)
  • Thread
  • 1/8 NPT
  • Grade
  • Industrial
  • Seal Material
  • Silicone
  • Material
  • ABS/Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 2.5 inWC
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • Polycarbonate Enclosure
  • Measure Pressure Of
  • Air and non-corrosive gases
  • Accessories
  • Mounting screws included
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Superior Versatility and Durability

The Series DPT10-R8 stands out with its flexible mounting orientation, making it adaptable to diverse installation scenarios. Its polycarbonate enclosure protects the device from harsh environments, with IP65 ingress protection on the front side ensuring reliable operation even in demanding industrial settings. The transmitter accommodates overpressure up to 15 inWC, adding an extra layer of robustness.


Precise and Rapid Measurement

Equipped with a high-precision sensor, the Series DPT10-R8 delivers accuracy within 1% of full scale, ensuring trustworthy results for critical applications. The rapid response time (<10 ms) makes it ideal for real-time process monitoring. Simple onboard push-buttons facilitate hassle-free zero and span adjustments, minimizing setup efforts and ensuring optimal performance.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC:


Q: How do you install the Sensocon DPT10-R8 differential pressure transmitter?

A: Installation is straightforwardthe transmitter can be mounted on any wall using the included mounting screws. Its design is orientation-insensitive, so you can position it as needed without affecting performance. Electrical connections are made easily via the screw terminal block.

Q: What types of media can the DPT10-R8 measure?

A: The Series DPT10-R8 is designed to measure differential pressure of air and non-corrosive gases, making it suitable for HVAC, cleanrooms, and a range of process control environments.

Q: When should zero and span adjustments be performed?

A: Zero and span adjustments using the onboard push-buttons should be carried out during initial setup and whenever calibration checks indicate a deviation from expected performance. This ensures sustained accuracy and reliability.

Q: Where can the DPT10-R8 be used, considering its ingress protection rating?

A: With IP65 ingress protection on the front, the transmitter is suitable for locations exposed to dust and low-pressure water jets. However, the rear has an IP30 rating, so its advisable to avoid installing it where it may be directly exposed to heavy moisture or dust on the back side.

Q: What benefits does the analog 4-20 mA output provide?

A: The 4-20 mA analog output ensures robust, interference-resistant signal transmission over long distances. This makes the device ideal for integration into industrial control and monitoring systems, even in electrically noisy environments.

Q: How does the DPT10-R8 respond to overpressure situations?

A: The transmitter is engineered to withstand overpressures up to 15 inWC, beyond its 0-2.5 inWC measurement range. This feature helps prevent sensor damage in case of accidental overpressure spikes during operation or maintenance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 25 mbar

Thread : ISO standard 1/8 NPT

Display : LCD Digital

Outer Size : 96 mm x 96 mm (approx.)

Measure Pressure Of : Other, Air and Noncorrosive Gases

Processing Type : Other, Electronic

Accuracy : 1% of full scale

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC

Thread : 1/8 NPT Female

Display : No Display (Output Transmitter)

Outer Size : Approx. 98 mm x 69 mm x 36 mm

Measure Pressure Of : Other, Air and Noncorrosive Gases

Processing Type : Other, Electronic (Transducer)

Accuracy : 1.5% of full scale

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Thread : Standard Process Connection

Display : Digital

Outer Size : Compact

Measure Pressure Of : Other, Air and Noncorrosive Gases

Processing Type : Other, Precision Calibrated

Accuracy : 1% F.S.

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 25 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 25 inWC

Thread : 1/8 NPT Female

Display : LED Digital Display

Outer Size : 110 x 90 x 36 mm (approx.)

Measure Pressure Of : Other, Air and Compatible Gases

Processing Type : Other, Electronic

Accuracy : 1% of Full Scale



Back to top