Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -125 - 125 Pa
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -125 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -125 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -125 - 125 Pa Specification

  • Grade
  • Industrial
  • Outer Size
  • Compact
  • Thread
  • Standard
  • Sensor Type
  • Differential Pressure Transmitter
  • Display
  • Digital
  • Seal Material
  • Silicone
  • Material
  • ABS, Polycarbonate
  • Processing Type
  • Electronic
  • Diameter
  • 85 mm
  • Mount Type
  • Panel/Wall Mount
  • Scale Range
  • -125 to 125 Pa
  • Accuracy
  • 1% of FS
  • Finishing
  • Powder Coated
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Bracket, User Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -125 - 125 Pa Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Eastern Europe, Middle East, Central America, South America, Western Europe, Asia, North America, Australia, Africa
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -125 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -125 - 125 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Versatile Pressure Measurement

The DPT1-R8 differential pressure transmitter is designed for industrial monitoring and control, offering a broad pressure range of -125 to 125 Pa. Its electronic processing and digital readout provide precise data for HVAC, filter monitoring, or process control applications. The compact form factor and selectable analog outputs enable easy customization to suit site-specific requirements.


Robust Construction for Demanding Environments

Built from durable ABS and polycarbonate, the DPT1-R8 withstands harsh conditions between -20C and +70C. With protection rated at IP54, this device is resilient against dust and limited water ingress. A powder-coated finish ensures added surface defense, making it ideal for industrial environments across manufacturing, supply, and facility management sectors.


Intuitive Setup and Adjustment

Installation is straightforward with panel or wall mounting and a screw terminal block for electrical connections. Zero and span can be finely tuned through onboard buttons, ensuring optimal calibration. The quick response time and digital display facilitate real-time monitoring and fast troubleshooting, while the included mounting bracket and clear user manual simplify deployment.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -125 - 125 Pa:


Q: How do I install the Sensocon DPT1-R8 differential pressure transmitter?

A: The DPT1-R8 is designed for easy installation with panel or wall mounting options. Use the supplied mounting bracket and refer to the user manual for step-by-step instructions. Ensure secure connections using the screw terminal block and select the desired output signal (4-20 mA or 0-10 V) before powering the device.

Q: What types of media can the DPT1-R8 measure pressure for?

A: This transmitter is specifically engineered to measure the differential pressure of air and non-corrosive gases. It should not be used with liquids or corrosive gases, ensuring sensor longevity and accuracy.

Q: When should I adjust the zero and span settings?

A: Zero and span adjustments are recommended during initial commissioning, after maintenance, or if you notice drift in readings. These adjustments help maintain accurate measurement within the specified range and are accessible via the dedicated onboard buttons.

Q: Where can the Sensocon DPT1-R8 be used?

A: The DPT1-R8 is suitable for industrial environments, including HVAC systems, clean room monitoring, and filter status indication. It operates effectively within a temperature range of -20C to +70C and can be mounted in locations protected by its IP54 enclosure.

Q: What is the process for selecting the output signal?

A: The device offers selectable 4-20 mA or 0-10 V output signals. Selection is typically made during installation by configuring internal settings according to the user manual instructions, matching your systems requirements for signal compatibility.

Q: How does using the DPT1-R8 benefit my application?

A: The DPT1-R8 provides rapid response (<1 s) and high accuracy (1% of full scale), enabling efficient and reliable monitoring of differential pressure. This supports optimal operation, energy savings, and timely maintenance in ventilation, air handling, and industrial processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar

Seal Material : EPDM

Processing Type : Other, Precise Electronic Sensing

Display : LED Digital

Finishing : Other, Matte, IP54 enclosure

Mount Type : Other, Panel Mount

Accuracy : 1% FS

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -6.4 - 6.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -6.4 - 6.4 mmWC

Seal Material : Nitrile Rubber (NBR) or Equivalent

Processing Type : Other, Solid State Electronic

Display : Digital LCD

Finishing : Other, ABS Plastic, Smooth Finish

Mount Type : Other, Wall Mount / Panel Mount

Accuracy : 1% of Full Scale

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Seal Material : Silicone

Processing Type : Other, Microprocessor Based

Display : LED Display

Finishing : Other, IP65 Rated Enclosure

Mount Type : Other, Wall Mount

Accuracy : 1% F.S.

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Seal Material : Integrated rubber gasket

Processing Type : Other, Electronic

Display : No Local Display

Finishing : Other, ABS Grey Housing

Mount Type : Other, Surface/Panel Mounting

Accuracy : 1% of F.S.



Back to top