Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC
Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC Specification

  • Outer Size
  • 110mm x 90mm x 36mm approx.
  • Thread
  • 1/8 NPT Female
  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure Sensor
  • Seal Material
  • Silicone
  • Display
  • Digital LCD
  • Material
  • ABS Plastic Enclosure
  • Processing Type
  • Microprocessor Controlled
  • Mount Type
  • Wall Mount
  • Scale Range
  • -0.5 to 0.05 in WC
  • Accuracy
  • 1.0% of Full Scale
  • Finishing
  • Matte ABS Casing
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Screws, Manual
 

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, North America
  • Main Domestic Market
  • All India
 

About Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precise Differential Pressure Measurement

Engineered for industrial applications, the DPT1-R8 offers reliable pressure measurement for air and non-corrosive gases. With an overpressure limit of 2 psi and a high level of accuracy, it ensures stable performance even in demanding environments. The digital LCD display provides clear, real-time readings, simplifying monitoring processes.


Flexible Output and Fast Response

The selectable output signals (4-20mA/0-10V) provide flexibility for integration with various control systems. With a rapid response time of 1 second, system operators can achieve timely and efficient feedback for dynamic control or safety monitoring applications.


Durable, User-Friendly Design

Protected by a matte ABS casing (IP54), this sensor is built to withstand harsh conditions. The wall mount design, front-panel zero adjustment, and included accessories streamline installation and maintenance, reducing downtime and operational costs.

FAQs of Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC:


Q: How is the Sensocon DPT1-R8 differential pressure sensor installed?

A: Installation is straightforward with the included mounting screws and manual. The sensor is designed for wall mounting and features a 1/8 NPT female thread for easy connection to air or non-corrosive gas lines. The compact ABS enclosure simplifies setup in industrial environments.

Q: What is the selectable output signal feature, and how does it benefit users?

A: The DPT1-R8 allows users to choose between 4-20mA and 0-10V output signals, making it compatible with a range of monitoring systems and controllers. This flexibility optimizes integration and reliable data transmission for specific application requirements.

Q: When should the zero adjust function be used?

A: Zero adjustment should be performed before the sensor is put into operation or after maintenance to ensure measurement accuracy. The push button on the front panel enables quick and simple calibration, reducing setup time.

Q: Where can the Series DPT1-R8 be applied?

A: This sensor is ideal for use in HVAC systems, cleanrooms, laboratories, and industrial process applications where accurate differential pressure monitoring of air and non-corrosive gases is required.

Q: What is the operating temperature range of this pressure sensor?

A: The DPT1-R8 operates efficiently in temperatures ranging from -10C to +60C. Its storage temperature extends from -20C to +70C, ensuring durability during transit and downtime.

Q: How does microprocessor control enhance performance?

A: Microprocessor controls provide precise and consistent measurements, enabling the sensor to maintain accuracy even in dynamic or fluctuating pressure environments. This process helps minimize error and improve overall reliability.

Q: What are the main benefits of using the Sensocon DPT1-R8?

A: Key benefits include robust construction, high accuracy, flexible output selection, fast response times, easy installation, and suitability for various industrial settings. Combined, these features offer reliable performance and help streamline pressure monitoring processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Outer Size : 4.6 x 1.9 x 1.5 (approx., including enclosure)

Accuracy : 1% of Full Scale

Mount Type : Other, Wall Mount

Finishing : Other, IP65 rated ABS plastic enclosure

Accessories : Mounting screws and manual included

Scale Range : 0 10.0 inWC

Sensocon USA Series DPT1-R8 - Range -25 - 25 Pa

Sensocon USA Series DPT1-R8 - Range -25 - 25 Pa

Outer Size : 88 mm x 88 mm x 39 mm (L x W x D)

Accuracy : 1% of Full Scale

Mount Type : Other, Wall/Panel Mount

Finishing : Other, Matte Plastic Housing

Accessories : Mounting Screws, Instruction Manual

Scale Range : 25 to 25 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -2.5 - 2.5 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mmWC

Outer Size : 90 x 90 mm (Front Panel)

Accuracy : 1.0% FS

Mount Type : Other, Panel Mount

Finishing : Other, Textured Plastic Enclosure

Accessories : Mounting Screws, User Manual

Scale Range : 2.5 to 2.5 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -250 - 250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa

Outer Size : 120 80 37 mm (Approx.)

Accuracy : 1.0% of Full Scale

Mount Type : Other, Wall Mount

Finishing : Other, ABS Plastic Housing

Accessories : Mounting Screws, User Manual

Scale Range : 250 to 250 Pa



Back to top