Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC
Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC Specification

  • Thread
  • 1/8 NPT Female Ports
  • Outer Size
  • 4.72 x 2.83 x 1.38 (120mm x 72mm x 35mm)
  • Sensor Type
  • Differential Pressure Transmitter
  • Seal Material
  • Silicone
  • Grade
  • Industrial
  • Display
  • No display (Transmitter only)
  • Material
  • ABS Plastic
  • Processing Type
  • Electronic
  • Diameter
  • Not applicable (rectangular housing)
  • Mount Type
  • Panel or Surface Mount
  • Scale Range
  • 0 - 1.0 inWC
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • ABS Plastic Housing
  • Measure Pressure Of
  • Air and Non-corrosive gases
  • Accessories
  • Mounting Screws, Installation Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Reliable Low Pressure Measurement

The DPT10-R8 delivers accurate differential pressure readings within a 0 to 1.0 inWC range, making it suitable for monitoring ventilation, filter condition, or airflow in ducts. With overpressure protection up to 10 inWC and a sturdy ABS enclosure, its built for longevity and reliability in industrial environments. Its fast response time ensures dynamic monitoring where swift feedback is crucial.


Flexible Installation and Output Options

Installation is straightforward with both panel and surface mount options, screw terminal block connections, and included mounting accessories. Its compact rectangular housing and selectable analog output (4-20 mA or 0-10 V) make it adaptable for a wide range of building automation and process control applications. The transmitter is supplied with a clear installation manual for ease of setup.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC:


Q: How is the Sensocon DPT10-R8 differential pressure transmitter typically installed?

A: The transmitter can be installed on either a panel or a surface using the included mounting screws. For electrical connections, a screw terminal block is provided, and clear guidance is found in the supplied installation manual.

Q: What types of media can this transmitter measure pressure for?

A: This model is designed to measure differential pressure of air and dry, non-aggressive gases only. It is not suitable for corrosive or wet media due to its sensor and housing materials.

Q: When should the push button zero and span adjustments be used?

A: Zero and span adjustments are used during initial commissioning or routine maintenance to calibrate the transmitter, ensuring accurate readings even after extended operation or if environmental conditions change.

Q: Where is the best place to mount the DPT10-R8 transmitter?

A: Optimal performance is typically achieved when the unit is mounted close to the point of measurement (such as a duct or filter) in a location protected from moisture and extreme temperatures. Its compact size and IP54 rating allow for flexible placement.

Q: What are the main benefits of choosing the DPT10-R8 for HVAC or industrial applications?

A: Key benefits include precise measurement (1% FS), fast response time (<50 ms), straightforward output selection, robust overpressure protection, and a user-friendly design for easy installation and calibration.

Q: How does the selectable output (4-20 mA or 0-10 V) benefit users?

A: Selectable analog outputs provide compatibility with a variety of control systems, enabling users to integrate the transmitter easily into new or existing HVAC and automation setups without additional signal conversion hardware.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 15 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 15 inWC

Finishing : Other, ABS Plastic Enclosure, Smooth Finish

Accessories : Mounting Screws, Installation Manual

Measure Pressure Of : Other, Air and Noncorrosive Gases

Seal Material : EPDM

Grade : Industrial

Processing Type : Other, Electronic Sensing & Signal Processing

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -12.7 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -12.7 - 12.7 mmWC

Finishing : Other, Powder Coated

Accessories : Mounting Screws, Instruction Manual

Measure Pressure Of : Other, Air and NonCorrosive Gases

Seal Material : Silicone

Grade : Industrial

Processing Type : Other, Electronic, Factory Calibrated

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Finishing : Other, Anodized Aluminum / ABS Plastic

Accessories : Mounting Kit Included

Measure Pressure Of : Other, Air and Noncombustible Gases

Seal Material : Silicone

Grade : Industrial

Processing Type : Other, Electronic

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 6250  Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 6250 Pa

Finishing : Other, Polycarbonate Enclosure, IP54 Rated

Accessories : Mounting Screws, User Manual

Measure Pressure Of : Other, Air and NonCorrosive Gases

Seal Material : Integrated Silicone Seal

Grade : Industrial Grade

Processing Type : Other, Electronic, Microcontroller Based



Back to top