Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 62 Pa
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 62 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa Specification

  • Seal Material
  • Silicone
  • Grade
  • Industrial
  • Outer Size
  • 92 mm 92 mm 36 mm
  • Sensor Type
  • Differential Pressure Transmitter
  • Display
  • Digital
  • Thread
  • Push-on Connectors
  • Material
  • ABS Plastic
  • Processing Type
  • Electronic
  • Diameter
  • 92 mm (front face)
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 62 Pa
  • Accuracy
  • 0.5% of Full Scale
  • Finishing
  • ABS Plastic Housing
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Installation Manual, Mounting Screws
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Middle East, Western Europe, Africa, Central America, Eastern Europe, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 62 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision and Versatility for Industrial Applications

Designed for HVAC systems, cleanrooms, laboratories, and automation setups, the Sensocon DPT1-R8 Differential Pressure Transmitter reliably measures low differential pressures. Its industrial-grade build, high accuracy, and fast response make it suited for demanding environments, ensuring stable air quality and system efficiency.


Easy Installation and User-Friendly Features

The DPT1-R8 transmitter is equipped with push-on connectors, a screw terminal block for secure electrical connection, and wall-mount capability. The push-button zero point adjustment and intuitive digital display contribute to ease of use, while the supplied installation manual and mounting screws support quick setup.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa:


Q: How do I install the Sensocon DPT1-R8 Differential Pressure Transmitter?

A: Mount the transmitter on a wall using the provided screws, connect the electrical wires to the screw terminal block, and attach the air pressure lines to the push-on connectors. Follow the installation manual for step-by-step guidance and ensure the device is powered by a 24 V DC supply.

Q: What is the primary benefit of using the DPT1-R8 in HVAC or laboratory environments?

A: The DPT1-R8 provides highly accurate and rapid differential pressure readings, which are essential for maintaining controlled air environments in HVAC, laboratory, or cleanroom applications. This ensures compliance with safety standards and optimizes system efficiency.

Q: When should the zero point adjustment be performed on this transmitter?

A: Zero point adjustment should be done after installation, system calibration, or when the device readings drift from the expected baseline. Simply use the push-button on the device to reset the zero point for accurate pressure measurements.

Q: Where is the DPT1-R8 differential pressure transmitter ideally used?

A: This transmitter is perfect for locations requiring precise air pressure monitoring such as HVAC units, cleanrooms, laboratories, and other industrial automation environments using air or non-corrosive gases.

Q: What process does the transmitter use to measure differential pressure?

A: The DPT1-R8 utilizes an electronic sensor housed in ABS plastic to measure the pressure difference between two points in an air system. The signal is then processed and outputted in analog (4-20 mA or 0-10 V) formats for integration with control systems.

Q: Is the Sensocon DPT1-R8 suitable for corrosive gases or liquids?

A: No, the DPT1-R8 is designed specifically to measure the differential pressure of dry, non-corrosive air or gases. It is not compatible with corrosive media or liquids due to its construction and media compatibility specifications.

Q: What are the advantages of the transmitters fast response time and high accuracy?

A: With a response time of less than 10 milliseconds and accuracy of 0.5% full scale, the transmitter captures pressure changes swiftly and reliably. This is beneficial for automated systems requiring real-time adjustments or for environments where precise pressure regulation is critical.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar

Processing Type : Other, Precise Electronic Sensing

Seal Material : EPDM

Sensor Type : Differential Pressure Transmitter

Finishing : Other, Matte, IP54 enclosure

Grade : Industrial

Mount Type : Other, Panel Mount

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 622 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 622 Pa

Processing Type : Other, Electronic

Seal Material : Silicone

Sensor Type : Differential Pressure Sensor

Finishing : Other, Powder Coated

Grade : Industrial Grade

Mount Type : Other, Wall Mount

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 380 mmWC

Processing Type : Other, Electronic

Seal Material : NBR (Nitrile Rubber)

Sensor Type : Differential Pressure Transmitter

Finishing : Other, ABS Plastic with Smooth Finish

Grade : Industrial Grade

Mount Type : Other, Wall Mount

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa

Processing Type : Other, Electronic

Seal Material : EPDM Rubber

Sensor Type : Differential Pressure Sensor

Finishing : Other, Matte Grey Plastic Housing

Grade : Industrial

Mount Type : Other, Wall Mount



Back to top