Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC
Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC Specification

  • Display
  • Digital Display
  • Thread
  • 1/8 NPT Female
  • Outer Size
  • 90 mm x 90 mm x 36 mm (Approx.)
  • Seal Material
  • EPDM
  • Sensor Type
  • Differential Pressure Sensor
  • Grade
  • Industrial
  • Material
  • ABS Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 0.25 in WC
  • Accuracy
  • 1% FS
  • Finishing
  • Industrial Grade Enclosure
  • Measure Pressure Of
  • Air and Non-Corrosive Gases
  • Accessories
  • Mounting Screws, Quick Guide
 

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, Middle East, Western Europe, Africa, Central America, South America, Asia, Eastern Europe, North America
  • Main Domestic Market
  • All India
 

About Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision Measurement for Critical Applications

Engineered for high accuracy, the Series DPT1-R8 offers 1% FS precision and digital readout, enabling meticulous differential pressure monitoring. Its fine resolution and quick response time make it ideal for sensitive environments like clean rooms and industrial air systems.


Flexible Output and User-Friendly Adjustments

This sensor supports both 0-10 VDC and 4-20 mA output signals for integration with varied control systems. Adjustment is straightforward using intuitive push buttons, guaranteeing smooth zero and span calibration for reliable, long-term performance.


Rugged Build for Reliable Service

Constructed with an industrial-grade ABS enclosure and IP54 protection, the DPT1-R8 withstands challenging operating conditions. The screw terminal block simplifies electrical connection, and its wall-mount design facilitates secure and accessible installation.

FAQs of Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC:


Q: How do I install the Sensocon Series DPT1-R8 differential pressure sensor?

A: Mount the DPT1-R8 on a wall using the included screws. Attach the pressure ports using 1/8 NPT female threads and connect the electrical wiring to the screw terminal block. Consult the quick guide for step-by-step instructions to ensure correct placement and wiring.

Q: What types of media can the Series DPT1-R8 measure?

A: The sensor is designed for monitoring pressure in dry air and non-aggressive gases. It should not be used with corrosive or wet media to preserve its function and sensor integrity.

Q: When should I use the zero and span adjustment feature?

A: Use the push button adjustment for zero and span during initial setup or anytime periodic recalibration is required to maintain measurement accuracy. This ensures the sensor reliably reflects true pressure changes within its specified range.

Q: Where is the optimal location to install this sensor?

A: Install the sensor in environments where accurate differential air or gas pressure monitoring is essential, such as HVAC systems, clean rooms, or filter banks. Choose a wall with minimal vibration and away from sources of moisture or corrosive substances.

Q: What benefits does the selectable output signal feature offer?

A: The DPT1-R8 enables integration into varied control systems by providing selectable 0-10 VDC or 4-20 mA outputs. This versatility allows seamless compatibility with modern building automation and industrial monitoring equipment.

Q: How does the IP54 protection rating enhance the sensors reliability?

A: IP54 protection ensures resistance against dust and splashing water, making the DPT1-R8 suitable for industrial settings where environmental factors could otherwise affect measurement accuracy or system durability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Series DPT Range Differential Pressure Transmitter

Series DPT Range Differential Pressure Transmitter

Accessories : Mounting Screws, Instruction Manual

Scale Range : 0 to 250 Pa, 0 to 400 Pa, 0 to 1000 Pa (Modeldependent)

Seal Material : Silicone or NBR

Outer Size : Approximately 120 mm x 80 mm x 40 mm

Thread : 1/8 NPT Female

Accuracy : 1% of Full Scale

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 50 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar

Accessories : Mounting Screws Included

Scale Range : 0 50 mbar

Seal Material : Silicone

Outer Size : Compact Housing (approx. 90 x 70 x 36 mm)

Thread : Barbed Pressure Ports

Accuracy : 1% F.S.

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 125 Pa

Accessories : User Manual, Mounting Screws

Scale Range : 0 125 Pa

Seal Material : Silicone

Outer Size : Approx. 90 x 95 x 36 mm (L x W x D)

Thread : Pushon nipple, 4 mm

Accuracy : 1% of Full Scale

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -5.0 - 5.0 inWC

Accessories : Mounting Bracket Included, Instruction Manual

Scale Range : 5.0 to 5.0 inWC

Seal Material : Silicone

Outer Size : Refer Manufacturer Specification

Thread : 1/8 NPT Female

Accuracy : 1% of Full Scale



Back to top