Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 2.5 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar Specification

  • Display
  • No Local Display
  • Sensor Type
  • Differential Pressure Sensor
  • Grade
  • Industrial Grade
  • Seal Material
  • Silicone
  • Outer Size
  • Approximately 85 x 80 x 36 mm
  • Thread
  • 1/8 NPT (Female)
  • Material
  • ABS Plastic, Electronic Components
  • Processing Type
  • Electronic / Digital Sensory Processing
  • Mount Type
  • Wall / Panel Mounting
  • Scale Range
  • 0 - 2.5 mbar
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • ABS Plastic Housing
  • Measure Pressure Of
  • Air / Non-Corrosive Gases
  • Accessories
  • Mounting Screws and Instruction Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 2.5 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Fast and Reliable Pressure Measurement

With a response time of less than 1 second, the DPT1-R8 provides quick and accurate readings for differential pressure applications. The electronic sensory processing enables real-time monitoring, essential for dynamic industrial environments where prompt feedback is critical for process control and safety.


Robust Design for Industrial Applications

Housed in sturdy ABS plastic with an IP54 protection grade, this transmitter withstands harsh industrial settings, including dust and moisture, while ensuring measurement integrity. Its compact size makes it easy to install on walls or panels, simplifying integration and maintenance.


Versatile Installation and Easy Configuration

Installation is streamlined with screw terminals and 1/8 NPT (Female) threads, allowing seamless connection to existing systems. Manual zero and span adjustment via potentiometer ensures calibration flexibility to meet various operational requirements, supporting long-term, consistent performance.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar:


Q: How is the Sensocon USA Differential Pressure Transmitter Series DPT1-R8 installed?

A: The DPT1-R8 can be mounted on walls or panels using the provided mounting screws. Connection to your process system is facilitated through 1/8 NPT (Female) threaded ports and screw terminal electrical connections, making integration straightforward.

Q: What media can the DPT1-R8 measure pressure for?

A: This transmitter is designed to measure the differential pressure of air and other non-corrosive gases only. It is not suitable for liquids or corrosive substances.

Q: When should I perform zero and span adjustment on this transmitter?

A: Zero and span adjustment should be performed during installation and periodically as part of routine calibration, especially if you detect any drift in measurement or after any significant process changes.

Q: Where is the output signal from the DPT1-R8 used?

A: The 4-20 mA output signal is commonly used in industrial automation systems, allowing seamless integration with PLCs, controllers, or data acquisition systems for continuous monitoring or process control.

Q: What process does the DPT1-R8 use for pressure measurement?

A: The DPT1-R8 utilizes electronic and digital sensory processing to accurately measure differential pressure. It provides rapid response (< 1 second) and an analog output proportional to the measured pressure.

Q: How does the transmitter benefit industrial operations?

A: Offering 1% full scale accuracy and fast response, the DPT1-R8 enhances process stability and energy efficiency by enabling precise control and monitoring in ventilation, filtration, and cleanroom applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.7 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.7 - 12.7 mmWC

Material : Other, Polycarbonate, ABS

Scale Range : 12.7 to 12.7 mmWC

Sensor Type : Differential Pressure Transmitter

Measure Pressure Of : Other, Air and NonCorrosive Gases

Display : Digital

Grade : Industrial

Series DPT Range Differential Pressure Transmitter

Series DPT Range Differential Pressure Transmitter

Material : Other, ABS Plastic Housing

Scale Range : 0 to 250 Pa, 0 to 400 Pa, 0 to 1000 Pa (Modeldependent)

Sensor Type : Differential Pressure Sensor

Measure Pressure Of : Other, Air and Noncorrosive Gases

Display : Digital LCD Display

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 254 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 254 mmWC

Material : Other, ABS, Electronic Components

Scale Range : 0 254 mmWC

Sensor Type : Differential Pressure Transmitter

Measure Pressure Of : Other, Air and Noncombustible Gases

Display : Digital

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 50 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar

Material : Other, ABS Plastic Housing

Scale Range : 0 50 mbar

Sensor Type : Differential Pressure Sensor

Measure Pressure Of : Other, Air and NonAggressive Gases

Display : No Display (Transmitter Output)

Grade : Industrial Grade



Back to top