Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar Specification

  • Thread
  • G1/8 (Female)
  • Grade
  • Industrial
  • Seal Material
  • Silicone
  • Sensor Type
  • Differential Pressure Transmitter
  • Display
  • LED Display
  • Outer Size
  • 66 mm x 90 mm x 36 mm
  • Material
  • ABS Plastic Housing
  • Processing Type
  • Microprocessor Based
  • Diameter
  • 66 mm
  • Mount Type
  • Wall Mount
  • Scale Range
  • -0.62 to 0.62 mbar
  • Accuracy
  • 1% F.S.
  • Finishing
  • IP65 Rated Enclosure
  • Measure Pressure Of
  • Air and Non-Corrosive Gases
  • Accessories
  • Mounting bracket, Calibration certificate, Instruction Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Western Europe, Middle East, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision Measurement for Critical Applications

The DPT1-R8 delivers high-accuracy differential pressure readings of air and non-corrosive gases, with a full-scale accuracy of 1%. With its fast response time and microprocessor-based processing, this transmitter is ideal for HVAC systems, cleanrooms, and industrial processes where precision and reliability are vital.


User-Friendly Features and Installation

Designed with the user in mind, the DPT1-R8 features straightforward screw terminal connections, wide operating temperature range, and convenient push-button zero/span calibration. Wall mounting options and compatibility with any orientation simplify integration into new or existing setups. Included accessories such as a mounting bracket and detailed manual assist with smooth installation.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar:


Q: How does the Sensocon DPT1-R8 differential pressure transmitter measure pressure?

A: The DPT1-R8 uses advanced microprocessor technology to measure the differential pressure between two points for air and non-corrosive gases. The pressure difference is converted into a 420 mA signal, which can be monitored and recorded for process control or data logging.

Q: What is the preferred mounting orientation for the DPT1-R8 transmitter?

A: This model is engineered for flexible installation and can be mounted in any orientation without compromising performance. Wall mounting is recommended for stability and ease of access, and a dedicated mounting bracket is included with the product.

Q: When should the zero and span adjustment be performed?

A: Zero and span adjustments should be executed during installation or periodic maintenance to ensure optimal accuracy. The DPT1-R8 incorporates a push-button system for straightforward recalibration, assisting users in preserving reliable readings over time.

Q: Where can the DPT1-R8 transmitter be used?

A: The DPT1-R8 is suitable for environments requiring precise differential pressure measurement of air or non-corrosive gases, such as cleanrooms, HVAC ductwork, laboratory facilities, and various industrial processes. Its robust ABS housing and versatile temperature range support use in challenging conditions.

Q: What are the benefits of the 4-20 mA (2-wire) output signal?

A: The 4-20 mA output ensures robust, interference-resistant signal transmission over long distances, making it compatible with most industrial control and monitoring systems. It simplifies wiring by requiring only two conductors for both power supply and signal transmission.

Q: How do users perform electrical connections for the DPT1-R8?

A: Electrical connections are accomplished via secure screw terminals inside the ABS enclosure. Detailed instructions are included in the manual, guiding users through safe and proper wiring procedures to power the device and connect it to control systems.

Q: What accessories accompany the DPT1-R8, and how do they support setup?

A: Every DPT1-R8 unit includes a mounting bracket, calibration certificate, and instruction manual. These accessories facilitate quick installation, verification of device accuracy, and provide clear guidelines for operation and maintenance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Grade : Industrial

Thread : Standard Process Connection

Measure Pressure Of : Other, Air and Noncorrosive Gases

Scale Range : 0 25 mbar

Display : Digital

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 62 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 62 Pa

Grade : Industrial

Thread : Pushon Connectors

Measure Pressure Of : Other, Air and Noncorrosive Gases

Scale Range : 0 62 Pa

Display : Digital

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Grade : Industrial Grade

Thread : 1/8 NPT (Female)

Measure Pressure Of : Other, Air and NonCorrosive Gases

Scale Range : 0 25.4 mmWC

Display : Without Display

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Grade : Industrial

Thread : 1/8 NPT Female

Measure Pressure Of : Other, Air and Noncorrosive Gases

Scale Range : 0 12.7 mmWC

Display : No Local Display

Sensor Type : Differential Pressure Transmitter



Back to top