Dwyer USA Magnehelic Gauges 0 To 80 Inch WC
Dwyer USA Magnehelic Gauges 0 To 80 Inch WC

Dwyer USA Magnehelic Gauges 0 To 80 Inch WC

Dwyer USA Magnehelic Gauges 0 To 80 Inch WC Specification

  • Outer Size
  • 4 inch (standard)
  • Thread
  • 1/8 NPT Female
  • Grade
  • Industrial
  • Sensor Type
  • Diaphragm
  • Display
  • Analog
  • Seal Material
  • Silicone rubber
  • Material
  • Die-cast aluminum case, acrylic cover
  • Dial Material
  • White acrylic
  • Pointer Material
  • Satin anodized aluminum
  • Processing Type
  • Precision-engineered
  • Diameter
  • 115 mm (approx.)
  • Glass Size
  • 115 mm viewing area
  • Mount Type
  • Surface or flush mount
  • Scale Range
  • 0 to 80 Inches Water Column (WC)
  • Accuracy
  • 2% of full scale
  • Finishing
  • Clear anodized aluminum case
  • Measure Pressure Of
  • Air and non-corrosive gases
  • Accessories
  • Two 1/8 NPT plugs, flush mounting adaptors, and self-tapping screws
 

Dwyer USA Magnehelic Gauges 0 To 80 Inch WC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Australia, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia, North America
  • Main Domestic Market
  • All India
 

About Dwyer USA Magnehelic Gauges 0 To 80 Inch WC

Dwyer USA Magnehelic Gauges 0 To 80 Inch WC


 Model Description 
 2080Differential pressure gage, range 0-80" w.c., minor divisions 2.0. 

 The industry standard in indicating low air or gas pressures of positive, negative, or differential pressures.

Large, easy-to-read 4" (102 mm) dial.

No manometer fluid to evaporate, freeze, or cause toxic or leveling problems.

INCLUDES

Two 1/8" NPT plugs, two 1/8" rubber tubing adapters, and three mounting adapters with screws

MORE ABOUT THIS ITEM

The Magnahelic guage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems, and pressures in fluid amplifier or fluidic systems. The gauge's motion is damped with high-viscosity silicone fluid. The zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Rugged design resists shock, vibration, and overpressure.

The helix is precision-made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the maganetic field to move the pointer across the scale. The samarium cobalt magnet is mounted at one end of the range spring and rotates the helix without mechanical linkages. 

Specifications & Description 

 

 
 Accuracy±3% full-scale 
 Dial Size (in)
 Dial Size (mm)102 
 Min Pressure (in WC)
 Max Pressure (in WC)0.5 
 Min Temperature (° F)20 
 Max Temperature (° F)140 
 Min Temperature (° C) 7
 Max Temperature (° C)60 
Liquid FillSilicone 
CaseAluminum 
 Lens MaterialPolycarbonate
 Process Connection1/8" NPT(F)
 Unit Of Measurement " WC
 Displayanalog dial
 Media CompatibilityAir and noncombustible, compatible gases 
 DescriptionMagnehelic Differential Pressure Gauge,  20800-80" w.c


Superior Accuracy in Air and Gas Pressure Monitoring

The Dwyer Magnehelic 2000-80 offers exceptional measurement accuracy, rated at 2% of the full scale. Suited for use in HVAC systems and industrial environments, it ensures reliable assessments for applications involving air velocity, filter resistance, and pressure differentials in rooms or ducts. The robust design and precision-engineered diaphragm make it a trusted choice for critical monitoring tasks.


Robust Construction for Industrial Reliability

Encased in a die-cast aluminum body with a clear anodized finish, this Magnehelic gauge is equipped to handle rugged workplace conditions. Its acrylic window, silicone rubber seals, and satin anodized aluminum pointer all contribute to durability and long-lasting performance. Suitable for vertical surface or flush mounting, it provides ease of installation and dependable operation under demanding circumstances.

FAQs of Dwyer USA Magnehelic Gauges 0 To 80 Inch WC:


Q: How can I install the Dwyer Magnehelic 2000-80 gauge?

A: You can install the gauge using the included flush mounting adaptors and self-tapping screws. It supports both surface and flush mounting orientations, with connections provided through 1/8" NPT female high and low pressure fittings on the side and back. Vertical mounting is recommended for optimal performance.

Q: What substances can be safely measured with this Magnehelic gauge?

A: The Dwyer Magnehelic 2000-80 is designed for measuring the pressure of air and non-corrosive gases. It is best not to use it with corrosive gases or liquids to prevent sensor or material damage.

Q: When should I use the zero adjustment screw on my gauge?

A: Utilize the external adjustment screw to recalibrate the zero point of your gauge if it drifts due to environmental changes or after installation, ensuring accurate readings. Always perform zero calibration with the pressure ports open to atmospheric pressure.

Q: Where is the Magnehelic 2000-80 commonly used?

A: This gauge is frequently employed in monitoring air velocity, filter resistance in HVAC systems, and pressure differentials in ducts, rooms, and building compartments. Industries such as manufacturing, pharmaceutical, and facility management often use it for pressure monitoring tasks.

Q: What are the benefits of using a precision-engineered analog gauge like this model?

A: The analog Magnehelic gauge offers visual clarity, high accuracy, and resilience in harsh environments. Its robust construction, easy maintenance, and external zero adjustment provide users with reliable, long-term operation without the need for complex electronics.

Q: How do I maintain the Dwyer Magnehelic gauge for long-term accuracy?

A: Regularly inspect the gauge for dust or debris on the viewing window, verify zero calibration, and ensure the pressure connections are free from blockages. Do not exceed the recommended overpressure limit (15 psig) to maintain integrity and accuracy.

Q: What accessories come with the Dwyer Magnehelic 2000-80?

A: Each unit is supplied with two 1/8" NPT plugs, flush mounting adaptors, and self-tapping screws for straightforward installation and setup.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer 2000 Magnehelic Differential Pressure Gage Category

Dwyer Series 2000 Magnehelic Differential Pressure Gauge

Dwyer Series 2000 Magnehelic Differential Pressure Gauge

Glass Size : Full dial view window

Material : Other, Diecast aluminum case, acrylic lens

Pointer Material : Aluminum

Measure Pressure Of : Other, Air and compatible gases

Mount Type : Other, Surface or flush mounting

Accuracy : 2% of full scale

Dwyer USA Magnehelic Gauges 0 To 20 Inch WC

Dwyer USA Magnehelic Gauges 0 To 20 Inch WC

Glass Size : 4 inches

Material : Other, Diecast aluminum case

Pointer Material : Aluminum

Measure Pressure Of : Other, Air and noncorrosive gases

Mount Type : Other, Surface or Flush Mount

Accuracy : 2% of Full Scale

Dwyer USA Magnehelic Gauges 0 To 20 Inch WC

Dwyer USA Magnehelic Gauges 0 To 20 Inch WC

Glass Size : 4 inch (101 mm)

Material : Other, Diecast aluminum body, acrylic lens

Pointer Material : Aluminum

Measure Pressure Of : Other, Air and noncorrosive gases

Mount Type : Other, Surface or Flush Mount

Accuracy : 2% of Full Scale

Dwyer USA Magnehelic Gauges 0 To 25 Inch WC

Dwyer USA Magnehelic Gauges 0 To 25 Inch WC

Glass Size : 105 mm

Material : Other, Diecast aluminum case, acrylic lens

Pointer Material : Aluminum

Measure Pressure Of : Other, Low pressure (air and noncorrosive gases)

Mount Type : Other, Flush or Surface Mount

Accuracy : 2% of full scale



Back to top