Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA
Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA

Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA

MOQ : 12 Pieces

Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA Specification

  • Outer Size
  • 110 mm (Approximate front bezel diameter)
  • Grade
  • Industrial Grade
  • Thread
  • 1/8 NPT Female
  • Bourdon Tube
  • Not Applicable (Uses diaphragm sensor)
  • Display
  • Analog Dial
  • Seal Material
  • Silicone rubber (standard)
  • Sensor Type
  • Differential Pressure Sensor
  • Material
  • Die-cast aluminum case, polycarbonate front cover
  • Dial Material
  • White aluminum with black/red markings
  • Pointer Material
  • Black aluminum pointer
  • Processing Type
  • Injection Molded Housing, Precision Machined Internals
  • Diameter
  • 100 mm (Nominal dial size)
  • Glass Size
  • Clear acrylic cover, 100 mm
  • Mount Type
  • Flush or Surface Mount
  • Scale Range
  • 0-20 kPa
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Molded plastic housing with black matte finish
  • Measure Pressure Of
  • Air and Compatible Non-corrosive Gases
  • Accessories
  • Two mounting brackets, screws, and instruction sheet
 

Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Paypal, Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa, Asia
  • Main Domestic Market
  • All India
 

About Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA

Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA

Dwyer 2000-20KPA MAGNEHELIC, DIFFERENTIAL PRESSURE GAUGE, 0/20KPA

  • Precision litho-printed scale is accurate and easy to read.
  • Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.
  • Pointer stops of molded rubber prevent pointer over-travel without damage.
  • "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.
  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.
  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.
  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.
  • Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.
  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.
  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.
  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.
  • Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.
  • O-ring seal for cover assures pressure integrity of case.


Reliable Pressure Monitoring for Critical Environments

Ideal for HVAC, clean room, and filter monitoring applications, the Dwyer Magnehelic Model 2000-20KPA ensures precise differential pressure readings. Its injection-molded housing and die-cast aluminum build guarantee durability in industrial settings, while its clearly marked dial allows for easy monitoring, boosting workplace safety and compliance. Mounting flexibility gives users seamless integration in diverse environments.


Effortless Installation and Adjustment

This model is equipped with side and back pressure taps, accommodating standard 1/8 NPT female threads. An external adjustment screw provides simple zero calibration without disassembly. The package includes two mounting brackets, screws, and an instruction manual, allowing for quick, straightforward installation whether flush or surface mounting is preferred.


Performance and Safety Built In

Engineered for reliability, the 2000-20KPA model operates safely with a maximum working pressure of 100 kPa and resists overpressure up to 103 kPa. Its core diaphragm sensor delivers rapid, accurate readings, with an IP52-protected front face to withstand routine industrial environments. The silicone rubber seal ensures leak-free performance when measuring air or compatible gases.

FAQs of Dwyer Magnehelic Differential Pressure Gauge Model 2000-20KPA:


Q: How is the Dwyer Magnehelic Model 2000-20KPA installed?

A: The gauge can be installed using either flush or surface mounting, and comes with mounting brackets and screws. The side and back pressure taps use standard 1/8 NPT female threads, ensuring compatibility with most installation setups.

Q: What applications is this pressure gauge best suited for?

A: This model is ideal for monitoring air and compatible non-corrosive gas pressures in HVAC systems, clean rooms, filter performance checks, fan and blower pressure measurements, and general industrial air handling.

Q: When should I use the external zero adjustment screw?

A: The external adjustment screw is used to recalibrate the zero point of the gauge, typically during initial setup or after maintenance, ensuring accuracy for each measurement cycle.

Q: What is the maximum safe pressure limit for this model?

A: The maximum safe working pressure is 100 kPa, with overpressure resistance up to 103 kPa (15 psi), helping to prevent accidental damage during unexpected pressure surges.

Q: Where are the pressure connections located on this gauge?

A: Both side and back pressure tap locations are available, giving flexibility for different installation requirements and simplifying integration with existing systems.

Q: What are the main usage benefits of the Magnehelic 2000-20KPA?

A: Key advantages include instantaneous analog readings, high durability, simple zero adjustment, and compatibility with a range of air and non-corrosive gases. Its accuracy and robust construction make it suitable for critical pressure monitoring.

Q: How does the gauge maintain protection against dust and humidity?

A: The front face of the gauge has an IP52 ingress protection rating, which guards against dust and limited moisture, ensuring reliable readings in standard industrial environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer 2000-200CM Magnehelic Differential Pressure Gauge

Dwyer 2000-200CM Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 (101.6 mm)

Pointer Material : Aluminum

Processing Type : Other, Machined

Scale Range : 0200 cm w.c. (water column)

Mount Type : Other, Surface or Flush

Dwyer 2005-AV Magnehelic Differential Pressure Gauge

Dwyer 2005-AV Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 inches (100 mm)

Pointer Material : Plastic

Processing Type : Other, Precision Mechanically Processed

Scale Range : 0500 Pa (Pascals)

Mount Type : Other, Surface or Flush Mount

Dwyer USA Model 2300-00 Magnehelic Gage Range 0.125-0-0.125 Inch WC

Dwyer USA Model 2300-00 Magnehelic Gage Range 0.125-0-0.125 Inch WC

Minimum Order Quantity : 12 Pieces

Diameter : 4 inch (100 mm) standard dial

Pointer Material : Other, Adjustable, highcontrast black pointer

Processing Type : Other, Machined

Scale Range : 0.12500.125 Inch WC (Water Column)

Mount Type : Other, Surface or flush mount

Dwyer 2300-200PA Differential Pressure Gage Range 100-0-100 Pa

Dwyer 2300-200PA Differential Pressure Gage Range 100-0-100 Pa

Minimum Order Quantity : 12 Pieces

Diameter : 4 inch (101.6 mm)

Pointer Material : Plastic

Processing Type : Other, Molded plastic

Scale Range : 1000100 Pa

Mount Type : Other, Surface/Panel Mount



Back to top