About Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C
Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C
Pressure switch/gage, range 0-2"w.c..05 minor divisions.
Model: 3002MRS
Combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gauge employing the durable, time-proven Magnehelic gauge design. Versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.
Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C.
Using solid state technology, there Series 3000MR and 3000MRS Photohelic switch/gauges combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" (122 mm) hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits. For applications requiring high cycle rates, choose 3000MRS models with SPST (N.O.) solid state relays. All models provide both low and high limit control and include 18-inch (45 cm) cable assemblies for electrical connections.
Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig (1.725 bar).
Range 0-2" W.C., .05 minor divisions
Dual Functionality for Reliable ControlThe 3002MRS Photohelic combines an easy-to-read analog gauge with two adjustable photoelectric switch relays, enabling accurate monitoring and automatic pressure control. Users benefit from the flexibility of visual inspection and automated response within a single compact unit. This dual capability streamlines installation and simplifies process management in a wide range of industrial settings.
Engineered for Harsh Industrial EnvironmentsThis gauge/switch is constructed with a die-cast aluminum housing, polycarbonate dial, and powder-coated case, offering both strength and durability. The front IP65 protection wards off dust and water, making it suitable for demanding applications. The products operating temperature range and corrosion-resistant materials ensure dependable operation in variable factory and processing plant conditions.
Precision and Efficiency in Pressure ManagementWith factory calibration to 2% FS accuracy and fast response times under one second, the 3002MRS supports high-precision control. Red setpoint markers on the analog display provide clear visual cues, while two independently adjustable SPDT relays allow users to configure alerts and process automation for enhanced efficiency and system protection.
FAQs of Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C:
Q: How do I install the Dwyer 3002MRS Photohelic Switch/Gauge for optimal performance?
A: To achieve optimal performance, mount the 3002MRS securely on a panel or surface using the included hardware. Connect to a 120/240VAC power supply and use the 1/8 NPT female threading for air or compatible gas connections. Carefully align the unit to allow easy viewing of the analog pointer and access to the adjustable setpoint markers.
Q: What pressure range can the Dwyer 3002MRS measure and control?
A: This model measures and controls differential pressure within a 0 to 2 inches water column (W.C.) range. It is designed for applications involving airflow or compatible gases, ensuring precise pressure management in industrial systems.
Q: When should I consider using the two adjustable SPDT relay setpoints?
A: Utilize the two adjustable SPDT relays when you need automatic switching or alarms at defined pressure thresholds. These setpoints can individually activate external equipment or signal alerts, enhancing system safety and process automation.
Q: Where is the ideal environment to use the Dwyer 3002MRS Photohelic gauge?
A: The 3002MRS is suitable for industrial and commercial settings requiring precise differential pressure regulation, especially where environmental conditions vary from 20 to 140F. Its IP65-protected front and robust housing make it ideal for dusty or moist environments.
Q: What process does the gauge use to detect and switch at specific pressures?
A: The 3002MRS utilizes photoelectric differential pressure sensing technology. As pressure reaches the preset values, the photoelectric sensor activates the SPDT relays, ensuring real-time, accurate switching with a response time of less than one second.
Q: How does using the Dwyer 3002MRS benefit industrial operations?
A: This product enhances operational efficiency by combining precise analog measurement with automatic pressure control. Its reliable, fast-acting switches minimize system downtime and reduce manual monitoring, contributing to safer, more productive industrial environments.