Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar
Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar Specification

  • Seal Material
  • Silicone
  • Sensor Type
  • Differential Pressure Sensor
  • Outer Size
  • 110 x 58 x 22 mm
  • Thread
  • Push-on connection, 6 mm
  • Grade
  • Industrial
  • Display
  • No Display
  • Material
  • ABS Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 6.2 mbar
  • Accuracy
  • 2% of full scale
  • Finishing
  • Matte, High Impact Plastic
  • Measure Pressure Of
  • Air & Non-Aggressive Gases
  • Accessories
  • Mounting Screws, Installation Manual
  • Operating Temperature Range
  • 0C to +50C
  • Media Compatibility
  • Clean, Dry Air and Non-Corrosive Gases
  • Mounting Orientation
  • Any position (recommended vertical)
  • Repeatability
  • < 0.2% FSO
  • Electrical Connection
  • Screw Terminals
  • Protection Class
  • IP54
  • Hysteresis
  • < 0.05% of full scale
  • Weight
  • Approx. 80 g
  • Power Supply
  • 10 35 VDC
  • Response Time
  • < 10 ms
  • Zero Adjustment
  • Yes (with push button)
  • Output Signal
  • 4-20 mA, 2-wire loop powered
  • Model
  • DPT10-R8
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Middle East, Western Europe, Africa, Central America, Eastern Europe, South America, Asia, North America, Australia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar  

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4


Easy Wall Mount Installation

Mounting the DPT10-R8 is direct thanks to its lightweight ABS plastic housing, wall-mount brackets, and included screws. The vertical orientation is recommended for optimal accuracy, but it can be installed in any position if needed. Screw terminals simplify wiring, while the compact design ensures it complements any facility layout without occupying much space.


Reliable Performance for Clean Air Applications

This transmitter is engineered for clean, dry air and non-aggressive gases. Its fast response time under 10 ms and output range of 0-6.2 mbar make it reliable for real-time monitoring in sensitive environments like laboratories, HVAC systems, and filter monitoring. The high-precision electronics deliver repeatable, stable outputs for consistent results.


Built for Durability and Ease of Use

Constructed with a matte-finish, high-impact ABS plastic enclosure and a silicone seal, the DPT10-R8 withstands demanding industrial environments. IP54 protection ensures dust and splash resistance. Zero adjustment via a push button and no display enhances simplicity and operational confidence, while clear installation manuals streamline the setup process.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar:


Q: How do I install the Sensocon DPT10-R8 differential pressure transmitter?

A: To install the DPT10-R8, mount it on a suitable wall surface using the provided screws and brackets. Connect the pressure ports to 6 mm push-on fittings, wire the power and signal terminals via the screw connectors, and follow the setup instructions in the manual. It is best installed vertically for maximum accuracy, but other orientations are permissible.

Q: What types of media can the DPT10-R8 measure pressure for?

A: The transmitter is designed for use with clean, dry air and non-aggressive, non-corrosive gases. It should not be used with liquids or harsh chemicals to ensure accurate measurements and prevent sensor damage.

Q: When should zero adjustment be performed?

A: Zero adjustment should be completed during initial setup and periodically thereafter to maintain measurement accuracy. The device includes a push button for easy zero calibration, ensuring reliable performance over time.

Q: Where can I use the DPT10-R8 pressure transmitter?

A: The DPT10-R8 is ideal for industrial environments, HVAC systems, clean rooms, laboratories, and filtration monitoringanywhere precise low differential air or gas pressure measurement is required. Its IP54-rated enclosure makes it suitable for indoor applications with moderate exposure to dust or moisture.

Q: What benefits does the 4-20 mA output provide?

A: The 4-20 mA analog output ensures robust, interference-resistant signal transmission over long cable distances, making it suitable for industrial process control systems. It simplifies integration with most PLCs, controllers, or display modules.

Q: How does the DPT10-R8 enhance process reliability?

A: With an accuracy of 2% of full scale, repeatability under 0.2% FSO, and hysteresis below 0.05%, the DPT10-R8 guarantees high measurement consistency. The fast <10 ms response time allows for real-time monitoring and timely process control adjustments.

Q: What is included in the box with the DPT10-R8?

A: Each DPT10-R8 comes with mounting screws and an installation manual, ensuring you have the essentials required for a straightforward setup.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 20 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 20 inWC

Measure Pressure Of : Other, Air and compatible noncombustible gases

Accessories : Mounting screws, manual included

Scale Range : 0 20 inWC

Processing Type : Other, Factory calibrated

Accuracy : 1% of full scale

Sensor Type : Capacitive differential pressure sensor

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Measure Pressure Of : Other, Air and NonCorrosive Gases

Accessories : Mounting Bracket, Manual, Calibration Certificate

Scale Range : 0 25.4 mmWC

Processing Type : Other, Electronic

Accuracy : 1% of Full Scale

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 30 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 30 inWC

Measure Pressure Of : Other, Gas, Air

Accessories : Mounting screws, Instruction Manual

Scale Range : 0 30 inWC (inches of Water Column)

Processing Type : Other, Electronic

Accuracy : 1% of Reading

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -37.5 - 37.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -37.5 - 37.5 mbar

Measure Pressure Of : Other, Air and noncorrosive gases

Accessories : Mounting screws, Calibration certificate

Scale Range : 37.5 to 37.5 mbar

Processing Type : Other, Electronic

Accuracy : 0.5% of FS

Sensor Type : Differential Pressure Transmitter



Back to top