Nicotra Forward Curved Centrifugal Fan ADH 355 R
Nicotra Forward Curved Centrifugal Fan ADH 355 R

Nicotra Forward Curved Centrifugal Fan ADH 355 R

MOQ : 1 Piece

Nicotra Forward Curved Centrifugal Fan ADH 355 R Specification

  • Power Source
  • Electric
  • Usage & Applications
  • HVAC Systems, Air Handling Units, Ventilation
  • Orientation
  • Horizontal
  • Efficiency
  • High
  • Temperature
  • Ambient up to 60C
  • Air Flow
  • 5000 m/h
  • Automation Grade
  • Manual
  • Product Type
  • Forward Curved Centrifugal Fan
  • Material
  • Galvanized Steel
  • Cooling System
  • Air Cooled
  • Noise Level
  • 75 dB(A)
  • Processing Time
  • Continuous
  • Capacity
  • 5000 m/h
  • Voltage
  • 415 V
  • Weight
  • 55 kg
  • Dimension (L*W*H)
  • 700 x 570 x 650 mm
  • Surface
  • Powder Coated
  • Number of Blades
  • Double Inlet, Multi-Blade
  • Insulation Class
  • Class F
  • Fan Speed
  • 1450 RPM
  • Impeller Diameter
  • 355 mm
  • Motor Protection
  • IP 54
  • Bearing Type
  • Ball Bearing
  • Mounting Type
  • Floor / Duct Mounted
  • Static Pressure
  • up to 600 Pa
  • Model
  • ADH 355 R
  • Phase
  • Three Phase
 

Nicotra Forward Curved Centrifugal Fan ADH 355 R Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Letter of Credit (L/C), Telegraphic Transfer (T/T), Paypal, Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About Nicotra Forward Curved Centrifugal Fan ADH 355 R

Nicotra Forward Curved Centrifugal Fan ADH 355 R

Product Benefits

Performance certified is for installation type B - free inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories)

Nicotra Gebhardt S.p.A certifies that the fan shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only 

ADH E and ADH G2E series

  • Sizes 0160 up to 0560
  • Scroll of galvanesed sheet steel with standing seam
  • Straight cut off
  • New cylindrical impeller with forward-curved blade geometry
  • Galvanised shaft
  • Pressure up to 2.200 Pa

ADH and ADH G2 Series

  • Sizes 0630 up to 1000
  • Lap jointed scroll of galvanized sheet steel with Pittsburgh-Seam and V-cut off
  • Pressure up to 1.800 Pa

 



Reliable Airflow for Demanding Applications

Designed to meet the rigorous demands of HVAC systems and industrial air handling, the Nicotra ADH 355 R combines high capacity and durability. With a double inlet, multi-blade impeller and robust 415 V three-phase motor, this fan ensures continuous and efficient ventilation, even under high static pressure conditions. Its floor or duct mounting flexibility makes installation seamless for diverse ventilation requirements.


Optimized Design for Efficiency and Durability

With its galvanized steel construction and powder-coated surface, the ADH 355 R offers corrosion resistance and longevity. The air-cooled, IP54-protected motor and high-efficiency ball bearings contribute to reduced maintenance needs and extended operating life. Operating at a quiet 75 dB(A), this centrifugal fan balances performance with user comfort and safety.

FAQs of Nicotra Forward Curved Centrifugal Fan ADH 355 R:


Q: How is the Nicotra ADH 355 R Centrifugal Fan typically installed?

A: The Nicotra ADH 355 R can be either floor or duct mounted, offering flexibility for different HVAC setups. Its horizontal orientation allows for straightforward integration into air handling units or ventilation shafts, whether upgrading existing systems or during new installations.

Q: What are the primary usage applications for this fan model?

A: This fan is primarily used in HVAC systems, air handling units, and general ventilation applications where a stable and continuous airflow of up to 5000 m/h is required. Its design and features make it suitable for both commercial and industrial environments.

Q: When should maintenance be performed on the ADH 355 R fan?

A: Regular maintenance should be conducted according to the facilitys usage patterns; generally, bearings and impeller areas should be inspected every six months for debris or wear. Thanks to its ball bearing system and air-cooled design, the fan requires minimal maintenance if operated under recommended conditions.

Q: Where can this centrifugal fan be used safely?

A: The ADH 355 R is designed for indoor use in locations such as office buildings, factories, warehouses, and commercial facilities. Its IP54 motor protection and Class F insulation make it safe for operation in environments with ambient temperatures up to 60C.

Q: What benefits does the double inlet, multi-blade configuration provide?

A: This configuration enhances the fans ability to deliver high volume airflow at a consistent rate and pressure, while maintaining efficient power consumption and lower operational noise. It also allows for better balance and reduced vibration during operation.

Q: How does the fan contribute to overall energy efficiency?

A: The high-efficiency design, combined with premium ball bearings and an air-cooled, three-phase motor, ensures minimal energy wastage and lower operating costs over time, making it suitable for sustained use in energy-conscious settings.

Q: What process is involved in integrating the ADH 355 R into an HVAC system?

A: Integration involves securing the fan at the designated mounting point, connecting it to the existing ductwork, and wiring it to a 415V, three-phase power source. Manual control allows operators to optimize airflow as required, and the robust construction ensures reliable performance within the system.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series ADH Nicotra Forward Curved Centrifugal Fan Category

Nicotra Forward Curved Centrifugal Fan ADH 400 R

Nicotra Forward Curved Centrifugal Fan ADH 400 R

Price 29000 INR

Minimum Order Quantity : 1 Piece

Efficiency : Up to 75%

Material : Galvanized Steel

Voltage : 415 V AC

Usage & Applications : HVAC, Ventilation, Exhaust, Air Handling Units

Nicotra Forward Curved Centrifugal Fan ADH 710 K

Nicotra Forward Curved Centrifugal Fan ADH 710 K

Price 91000 INR

Minimum Order Quantity : 1 Piece

Efficiency : High Efficiency

Material : Galvanized Steel

Voltage : 415 V

Usage & Applications : Ventilation, HVAC, Air Handling Units, Industrial Exhaust/Fume Extraction

Nicotra Forward Curved Centrifugal Fan ADH 200 R

Nicotra Forward Curved Centrifugal Fan ADH 200 R

Price 15500 INR

Minimum Order Quantity : 1 Piece

Efficiency : High volumetric and static efficiency

Material : Galvanized Steel / Mild Steel construction

Voltage : 230 V / 415 V

Usage & Applications : HVAC Systems, Air Handling Units, Ventilation, Exhaust Systems

Nicotra Forward Curved Centrifugal Fan ADH 1400 X1

Nicotra Forward Curved Centrifugal Fan ADH 1400 X1

Minimum Order Quantity : 1 Piece

Efficiency : High Efficiency

Material : Galvanized Steel

Voltage : 415 V

Usage & Applications : HVAC systems, Ventilation, Exhaust, Industrial air movement



Back to top