About JISS GALAXY DIFFERENTIAL PRESSURE GAUGE 0-500 PASCALS

JISS GALAXY DIFFERENTIAL PRESSURE GAUGE 0-500 PASCALS
Series G2000JISS GALAXYDifferential Pressure Gaugesare Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21140-660
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure -Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections -1/8" female NPT duplicate high and low pressure taps-one pair side and one pair back
- Housing- Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand168 Hour Salt Spray Corrosion Test
- Accuracy-i2% of full span at 70 (21 (i3% on-0,and i4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive AndNegative Pressure
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
- Exact And Stable Fixed Position Of Needle
- The Gauge Has Great Antiknock Characteristics
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
JISS GALAXYByModel NumberPopularity
| Model |
Description |
| G2201 |
Differential Pressure Gage,Range 0-1 PSI,Minor Divisions .02 |
| G2202 |
Differential Pressure Gage,Range0-2PSI,Minor Divisions.05 |
| G2203 |
Differential Pressure Gage,Range0-3 PSI,Minor Divisions .10 |
| G2204 |
Differential Pressure Gage,Range0-4 PSI,Minor Divisions .10 |
| G2205 |
Differential Pressure Gage,Range0-5 PSI,Minor Divisions .10 |
| G2210 |
Differential Pressure Gage,Range0-10 PSI,Minor Divisions .20,MP Option Standard |
| G2215 |
Differential Pressure Gage,Range0-15 PSI,Minor Divisions .50,MP Option Standard |
| G2220 |
Differential Pressure Gage,Range0-20 PSI,Minor Divisions .50,MP Option Standard |
| G2230 |
Differential Pressure Gage,Range0-30 PSI,Minor Divisions 1.0,HP Option Standard
|
Additional Information:

Versatile Applications Across IndustriesThe JISS Galaxy Differential Pressure Gauge is designed to cater to industries requiring precise gas pressure monitoring, such as pharmaceuticals, power plants, and chemical plants. Its adaptability, durability, and high accuracy make it suitable for various demanding environments, providing value for distributors, manufacturers, and engineering professionals alike.
Precision Engineered for AccuracyThis gauge features a finely calibrated analog mechanism with an accuracy of 2% full scale for most ranges, ensuring trustworthy readings. The inclusion of duplicate pressure taps-both side and back-improves installation flexibility without compromising measurement integrity, supporting diverse operational requirements.
FAQ's of JISS GALAXY DIFFERENTIAL PRESSURE GAUGE 0-500 PASCALS:
Q: How is the JISS Galaxy Differential Pressure Gauge installed?
A: The gauge is equipped with four 1/8" female NPT taps-two on the side and two on the back-allowing flexible mounting configurations on panels or control boards, depending on your setup needs.
Q: What types of media can this gauge measure?
A: This device is calibrated specifically for measuring the differential pressure of gases, making it suitable for clean air and other non-corrosive gases typically found in industrial and laboratory applications.
Q: When should I recalibrate or maintain the pressure gauge?
A: Routine recalibration and inspection are recommended annually or following exposure to pressure spikes or harsh conditions to maintain accuracy and prolong the gauge's service life.
Q: Where is this differential pressure gauge commonly used?
A: It is widely used in pharmaceutical manufacturing, power generation, cement, steel, fertilizer, and textile industries due to its reliability and precise pressure measurement capability.
Q: What are the benefits of the dual pressure taps design?
A: Having a pair of pressure taps on both the side and the back allows versatile mounting and connection options, simplifying installation and integration into existing equipment layouts.
Q: How does the accuracy of the JISS Galaxy Gauge impact operations?
A: With an accuracy of 2% of full scale (with minor variations on certain ranges), the gauge ensures process safety, equipment protection, and quality control, minimizing the risk of undetected pressure deviations.