About TOP BRAND JISS GALAXY DIFFERENTIAL PRESSURE GAUGE

TOP BRAND JISS GALAXY DIFFERENTIAL PRESSURE GAUGE
Series G2000JISS GALAXYDifferential Pressure Gaugesare Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21140-660
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure -Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections -1/8" female NPT duplicate high and low pressure taps-one pair side and one pair back
- Housing- Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand168 Hour Salt Spray Corrosion Test
- Accuracy-i2% of full span at 70 (21 (i3% on-0,and i4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive AndNegative Pressure
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
- Exact And Stable Fixed Position Of Needle
- The Gauge Has Great Antiknock Characteristics
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
JISS GALAXYByModel NumberPopularity
- FILTER BY
- Range - Pascals
| Model |
Description |
| G2000-100PA |
Differential Pressure Gage, Range 0-100 Pa,Minor Divisions 2.0,Calibrated For Vertical Scale Position. |
| G2000-125PA |
Differential Pressure Gage, Range 0-125 Pa,Minor Divisions 5.0,Calibrated For Vertical Scale Position. |
| G2000-250PA |
Differential Pressure Gage, Range 0-250 Pa,Minor Divisions 5.0. |
| G2000-300PA |
Differential Pressure Gage, Range 0-300 Pa,Minor Divisions 10.0. |
| G2000-30PA |
Differential Pressure Gage, Range 0-30 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
| G2000-500PA |
Differential Pressure Gage, Range 0-500 Pa,Minor Divisions 10.0. |
| G2000-60PA |
Differential Pressure Gage, Range 0-60 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
| G2000-750PA |
Differential Pressure Gage, Range 0-750 Pa,Minor Divisions 25.0.
|
Additional Information:

Precision and Versatility for Industrial Applications
This differential pressure gauge is designed to meet the rigorous demands of industrial facilities. Its broad range of scale options and accurate readings make it a versatile tool for ensuring safe and efficient operation in critical environments. The combination of a clear display and rugged alloy construction provides durability and ease of use for both daily monitoring and troubleshooting.
Built to Last with Reliable Performance
Manufactured with high-quality metal alloy and a plastic dial face, this gauge withstands tough working environments. The dual pairs of pressure taps and a secure back mount enable flexible installation. All key components, from the alloy pointer to the 4-inch diameter face, are designed for extended service life and consistent operation across industries.
FAQ's of TOP BRAND JISS GALAXY DIFFERENTIAL PRESSURE GAUGE:
Q: How is the TOP BRAND JISS GALAXY Differential Pressure Gauge installed?
A: The gauge can be mounted using a back mount design and connects via 1/8" female NPT fittings. It offers duplicate high and low pressure taps-one pair on the side and one on the back-for easy integration into existing systems.
Q: What media can this differential pressure gauge measure?
A: This gauge is suitable for measuring differential pressure in gas media, making it ideal for various plant operations such as pharmaceutical, power, cement, steel, fertilizer, and textile plants.
Q: When should the differential pressure gauge be calibrated or checked for accuracy?
A: Calibration is typically recommended periodically or when accuracy becomes critical, especially if the gauge is used in regulated environments. Its 2% accuracy suits most industrial requirements, but regular checks ensure ongoing reliability.
Q: Where can the gauge be purchased or obtained?
A: This product is available through distributors, exporters, importers, manufacturers, suppliers, traders, and wholesalers, primarily across India.
Q: What is the process for connecting the gauge to a system?
A: Simply connect the high and low pressure points of your process to the corresponding duplicate taps on the gauge using the 1/8" NPT female threads. Ensure connections are secure to prevent leaks, and mount as per your setup requirements.
Q: How does using this gauge benefit my plant operations?
A: By accurately tracking differential pressures, the gauge helps optimize process efficiency, maintain safety standards, and detect issues early, thus minimizing downtimes and ensuring smooth plant performance.
Q: What sizes and scales does the gauge support?
A: The gauge supports a 4" (100mm) diameter dial and can display readings in a variety of units including MM WC, CM, PAC, KPA, INCH, PSI, and MBAR, adding flexibility for diverse application needs.