GEMTECH Instruments 2000-60PA Differential Pressure Gage 0-60 PaSeries G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter,Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21 140 -6 60
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure-Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections-1/8" female NPT duplicate high and low pressure taps-one pair side and one pair back
- Housing-Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy-2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
- Exact And Stable Fixed Position Of Needle
- The Gauge Has Great Antiknock Characteristics
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
| Model |
Description |
| G2000-100PA |
Differential Pressure Gage, Range 0-100 Pa, minor divisions 2.0, calibrated for vertical scale position. |
| G2000-125PA |
Differential Pressure Gage, Range 0-125 Pa, minor divisions 5.0, calibrated for vertical scale position. |
| G2000-250PA |
Differential Pressure Gage, range 0-250 Pa, minor divisions 5.0. |
| G2000-300PA |
Differential Pressure Gage, Range 0-300 Pa, minor divisions 10.0. |
| G2000-30PA |
Differential Pressure Gage, range 0-30 Pa, minor divisions 1.0, calibrated for vertical scale position. |
| G2000-500PA |
Differential Pressure Gage, Range 0-500 Pa, minor divisions 10.0. |
| G2000-60PA |
Differential Pressure Gage, range 0-60 Pa, minor divisions 1.0, calibrated for vertical scale position. |
| G2000-750PA |
Differential Pressure Gage, Range 0-750 Pa, minor divisions 25.0. |
| G2300-100PA |
Differential Pressure Gage, Range 50-0-50 Pa, minor divisions 2.0, calibrated for vertical scale position. |
| G2300-120PA |
Differential Pressure Gage, Range 60-0-60 Pa, minor divisions 2.0. |
| G2300-250PA |
Differential pressure gage, range 125-0-125 Pa, minor divisions 5.0. |
| G2300-500PA |
Differential Pressure Gage, Range 250-0-250 Pa, minor divisions 10.0. |
| G2300-60PA |
Differential Pressure Gage, Range 30-0-30 Pa, minor divisions 1.0, calibrated for vertical scale position. |
Additional Information:

Trusted Accuracy Across Industrial ApplicationsThe GEMTECH 2000-60PA delivers reliable differential gas pressure measurement with accuracy ratings from 2% to 4% of full scale, depending on model and range. Its robust construction, designed specifically for challenging environments like power plants, cement factories, and more, ensures minimal maintenance and consistent readings.
Versatile Scale for Enhanced ReadabilityChoose your preferred scale range-MM WC, CM, PAC, KPA, INCH, or PSI. The gauge's large, clear dial face ensures that readings remain easily visible and interpretable, thus reducing the chance of human error and fostering operational safety.
Designed for Easy Installation and Flexible MountingEquipped with dual high and low pressure taps (side and back) and a back mount design, the GEMTECH 2000-60PA supports seamless integration into new or existing systems. The lightweight, compact structure (550 g) allows for fast setup and easy repositioning as needed.
FAQ's of GEMTECH Instruments 2000-60PA Differential Pressure Gage 0-60 Pa:
Q: How is the GEMTECH 2000-60PA Differential Pressure Gage installed?
A: This pressure gauge features a back mount design and provides duplicate high and low pressure taps (1/8" female NPT) on both the side and back, making installation straightforward in various pipeline configurations.
Q: What media can this differential pressure gauge measure?
A: The device is specifically engineered to measure the differential pressure of gases in industrial settings, ensuring reliable readings in environments such as power plants, steelworks, cement factories, and textile units.
Q: When should I use the different scale ranges provided (MM WC, CM, PAC, KPA, INCH, PSI)?
A: The gauge's multiple scale options allow for flexible usage depending on user preference or local instrumentation standards; simply select the range that best matches your application or regional measurement norms.
Q: Where is this pressure gauge typically applied?
A: It is widely used in multiple industries across India, including power plants, cement plants, steel manufacturing, fertilizer production, and textile operations, for monitoring gas pressure with high precision.
Q: What is the accuracy of the GEMTECH 2000-60PA?
A: Depending on the selected model and range, the accuracy varies from 2% to 4% of full scale, ensuring dependable results for critical differential pressure monitoring.
Q: What are the benefits of choosing this gauge over others?
A: Users benefit from reliable accuracy, a robust metal alloy and plastic build, flexible mounting options, a clear analog readout, and compatibility with various industrial standards.
Q: How should the gauge be maintained to ensure long-term performance?
A: Routine checks for leaks or blockages at the pressure connections, regular cleaning of the dial face and pointer, and verifying system pressure ranges will help maintain accuracy and durability over time.