Series G2000 GEMTECH Differential Pressure GaugesThere Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct, Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
| Model |
Description |
| G2201 |
Differential Pressure Gage, Range 0-1 PSI,Minor Divisions .02. |
| G2202 |
Differential Pressure Gage, Range 0-2 PSI,Minor Divisions .05. |
| G2203 |
Differential Pressure Gage, Range 0-3 PSI,Minor Divisions .10. |
| G2204 |
Differential Pressure Gage, Range 0-4 PSI,Minor Divisions .10. |
| G2205 |
Differential Pressure Gage, Range 0-5 PSI,Minor Divisions .10. |
| G2210 |
Differential Pressure Gage, Range 0-10 PSI,Minor Divisions .20, MP Option Standard. |
| G2215 |
Differential Pressure Gage, Range 0-15 PSI,Minor Divisions .50, MP Option Standard. |
| G2220 |
Differential Pressure Gage, Range 0-20 PSI,Minor Divisions .50, MP Option Standard. |
| G2230 |
Differential Pressure Gage, Range 0-30 PSI,Minor Divisions 1.0, HP Option Standard.
|
Additional Information:

Versatile Pressure MeasurementOur GEMTECH Differential Pressure Gauge for NARALA stands out with its compatibility across multiple pressure scales, supporting MM WC, CM, PAC, KPA, INCH, PSI, and MBAR units. Accurate to within 2% of full scale, the gauge ensures consistency and reliability for demanding environments, enhancing process efficiency and safety.
Robust Construction & Easy InstallationThe gauge features a sturdy metal alloy body, a plastic dial, and an alloy pointer-purpose-built for longevity. Its 4-inch face and clear display offer excellent readability. With back mount installation and dual high/low pressure taps (side and back), the setup process is straightforward and adaptable to different industrial requirements.
FAQ's of GEMTECH DIFFERENTIAL PRESSURE GAUGE FOR NARALA:
Q: How do I install the GEMTECH Differential Pressure Gauge for NARALA?
A: To install, mount the gauge using the back bracket provided. Connect the high and low pressure lines to their respective 1/8-inch NPT female duplicate taps located both on the side and back. Ensure all connections are securely fitted before use to maintain measurement accuracy.
Q: What types of pressure units does the gauge display?
A: The GEMTECH differential pressure gauge supports multiple scales, including MM WC, CM, PAC, KPA, INCH, PSI, and MBAR. This versatility makes it suitable for diverse process monitoring needs across various industries.
Q: When should calibration be performed for optimal accuracy?
A: It is recommended to calibrate the gauge before initial use and then periodically according to your facility's standard operating procedures or whenever accuracy is critical, especially if used in high-precision environments like pharmaceutical manufacturing.
Q: Where can this pressure gauge be used?
A: This gauge is suited for installation in environments such as pharmaceutical, power, cement, steel, fertilizer, and textile plants. Its robust construction ensures reliable performance under demanding industrial conditions.
Q: What is the benefit of having both side and back pressure taps?
A: Duplicate high and low pressure taps on both side and back provide flexible installation options, allowing adaptation to space constraints or specific process layouts, thus simplifying integration into existing equipment.
Q: How can I ensure accurate pressure readings with this gauge?
A: To ensure accuracy, install the gauge upright at the recommended temperature (around 70F/21.1C), securely connect the pressure lines, and regularly calibrate according to environmental demands and usage frequency.