Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70???(21??????(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range 0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range 0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range 0-80 MM W.C., Minor Divisions 2.0. |
Additional Information:

Versatile Industrial Applications
GEMTECH Differential Pressure Gauges are expertly crafted for demanding sectors such as pharmaceuticals, cement production, power generation, steel manufacturing, fertilizers, and textiles. The robust metal alloy construction and precise calibration make them suitable for critical pressure monitoring tasks. Their adaptability ensures optimal usage across various process environments.
Precision and Reliability in Measurement
These gauges deliver consistent and accurate analog readings for different pressure ranges including MM WC, CM, PAC, KPA, INCH, PSI, and MBAR. With an accuracy of 2% of full span at 21C, users benefit from dependable performance and minimal error. The clear dial and alloy pointer allow quick, easy interpretation on-site.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Near LIONS HOSPITAL:
Q: How can I find GEMTECH Differential Pressure Gauge dealers near LIONS HOSPITAL?
A: You can locate authorized GEMTECH dealers by searching online directories, contacting nearby industrial supply distributors, or inquiring with LIONS HOSPITAL's facility maintenance department for recommendations on local suppliers.
Q: What processes is the GEMTECH Differential Pressure Gauge best suited for?
A: This gauge is ideal for pressure measurement in pharmaceuticals, power plants, cement and steel industries, fertilizer production, and textile mills, supporting a range of applications where accurate gas pressure monitoring is essential.
Q: When should the GEMTECH differential gauge be serviced or calibrated?
A: Regular calibration is recommended every 6-12 months or as specified by your facility's maintenance schedule to maintain its 2% full span accuracy, especially in critical process environments.
Q: Where should I install the GEMTECH Differential Pressure Gauge for optimal performance?
A: Install the gauge on gas pressure lines closest to the measurement point, utilizing the 1/8" female NPT side or back threads as appropriate for your system. The back mount design supports secure panel installations.
Q: What are the key benefits of using this pressure gauge in my facility?
A: Benefits include precise analog pressure readings, robust metal construction for durability, compatibility with various industrial gases, and user-friendly features like clear scale markings across different units.
Q: How do I interpret the readings on the GEMTECH pressure gauge?
A: The analog dial clearly displays pressure values in your selected range (MM WC, CM, PAC, KPA, INCH, PSI, or MBAR). Read the value indicated by the alloy pointer, ensuring measurements are taken under standard operating conditions for accuracy.