Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
Differential Pressure Gauge,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
Differential Pressure Gauge,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
Differential Pressure Gauge,Range 0-150 MM W.C. |
| G2000-15MM |
Differential Pressure Gauge,Range 0-15 MM W.C. |
| G2000-200MM |
Differential Pressure Gauge,Range 0-200 MM W.C. |
| G2000-250MM |
Differential Pressure Gauge,Range 0-250 MM W.C. |
| G2000-25MM |
Differential Pressure Gauge,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
Differential Pressure Gauge,Range 0-300 MM W.C. |
| G2000-50MM |
Differential Pressure Gauge,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
Differential Pressure Gauge,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
Differential Pressure Gauge,Range 0-80 MM W.C., Minor Divisions 2.0. |
Additional Information:

Versatile Industrial Pressure Measurement
GEMTECH Differential Pressure Gauges are engineered for reliable analog pressure measurement in a range of industry settings. Created with high-quality metal alloy and precision components, these gauges accommodate a variety of applications and environments. Their adaptable scale ranges and robust design ensure suitability for gas measurement in critical industrial processes, enhancing overall operational safety and accuracy.
Accurate and Durable Design
With a carefully crafted alloy pointer and a 4-inch dial made from sturdy materials, GEMTECH pressure gauges maintain remarkable accuracy-up to 2% FS for standard ranges. Their durable plastic dial provides clear readings even in challenging environments, ensuring long-term use. The back-mount configuration and multiple tapping options allow easy installation and integration into existing systems.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Near EHIRCL:
Q: How do I install the GEMTECH Differential Pressure Gauge with the back mount type?
A: To install the GEMTECH Differential Pressure Gauge with a back mount, use the provided mounting hardware and connect the 1/8" female NPT high and low pressure taps at the back or sides as needed. Ensure the pressure source is compatible with the gauge's specifications for optimal performance.
Q: What materials are used in the construction of the GEMTECH pressure gauge, and how does this benefit industrial usage?
A: This gauge is constructed using a metal alloy body, an alloy pointer, and a plastic dial. These materials make the gauge both robust and resistant to the challenging conditions typically found in industrial environments, such as power plants and chemical factories.
Q: Where can I find authorized dealers or distributors of GEMTECH Differential Pressure Gauges near EHIRCL, India?
A: Authorized GEMTECH dealers, distributors, and suppliers are available throughout India, including in regions near EHIRCL. You can contact GEMTECH directly or visit their website to locate the nearest authorized source for purchasing and support.
Q: What pressure ranges and measuring units are supported by this gauge?
A: The GEMTECH Differential Pressure Gauge offers versatile measurement units such as MM WC, CM, PAC, KPA, INCH, and PSI across various scale ranges, making it adaptable for diverse industrial requirements.
Q: What is the accuracy specification of the GEMTECH -HA model gauge?
A: The accuracy is 2% of Full Scale (FS) for the -HA model (with adjustments to 3% and 4% for specific lower ranges), ensuring dependable readings for critical processes.
Q: How is this gauge typically used across industries like pharmaceuticals, power plants, or steel plants?
A: The gauge is employed to monitor and measure the differential pressure of gas in pipelines, filters, or equipment, helping maintain precise operating conditions and ensuring safe, efficient industrial operation.
Q: What is the process for calibrating or maintaining this differential pressure gauge?
A: Calibration should be performed periodically by qualified personnel using a reference standard. Maintenance includes inspecting connection points, verifying the integrity of the dial and pointer, and ensuring the gauge operates within its specified temperature and pressure ranges.