Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter,Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21 140 -6 60
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure-Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections-1/8" female NPT Duplicate High and Low pressure taps-one pair side and one pair back
- Housing-Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy-2% of full span at 70 (21 (3% on -0,and 4% on -00
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification Also Can be Ordered
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
- Exact And Stable Fixed Position Of Needle
- The Gauge Has Great Antiknock Characteristics
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range-CM Of Wate
| Model |
Description |
| G2000-100CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-100 CM Minor Divisions 2.0 |
| G2000-150CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-150 CM Minor Divisions 5.0 |
| G2000-15CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-15 CM Minor Divisions .50 |
| G2000-200CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-200 CM Minor Divisions 5.0 |
| G2000-20CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-20 CM Minor Divisions .50 |
| G2000-250CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-250 CM Minor Divisions 5.0 |
| G2000-25CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-25 CM Minor Divisions .50 |
| G2000-300CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-300 CM Minor Divisions 10.0 |
| G2000-50CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-50 CM Minor Divisions 1.0 |
| G2000-80CM |
DIFFERENTIAL PRESSURE GAUGE,Range 0-80 CM Minor Divisions 2.0 |
| G2300-10CM |
DIFFERENTIAL PRESSURE GAUGE,Range 5-0-5 CM Minor Divisions .20 |
| G2300-30CM |
DIFFERENTIAL PRESSURE GAUGE,Range 15-0-15 CM Minor Divisions 1.0 |
| G2300-4CM |
DIFFERENTIAL PRESSURE GAUGE,Range 2-0-2 CM Minor Divisions .10 |
Additional Information:

Robust Construction for Demanding Environments
Built with a strong metal alloy case and a plastic dial, the GEMTECH Differential Pressure Gauge withstands harsh conditions in power plants, cement production, and steel processing facilities. Its 4-inch diameter dial makes readings clear even from a distance, ensuring dependable use in high-traffic or industrial settings.
Versatile Measurement and High Accuracy
The gauge can read multiple pressure units, including MM WC, CM, PAC, KPA, INCH, and PSI, resulting in flexible application across industries. Its accuracy of up to 2% of full scale ensures reliable pressure assessment, supporting safety and efficiency in pharmaceutical, fertilizer, textile, and other critical sectors.
FAQ's of GEMTECH DIFFERENTIAL PRESSURE GAUGE 100% Original:
Q: How is the GEMTECH Differential Pressure Gauge installed?
A: The GEMTECH Differential Pressure Gauge is designed for back mounting, making it suitable for panel or surface installation in industrial setups. Ensure the mounting surface is stable and use appropriate fittings to securely attach the gauge and connect the required gas lines.
Q: What types of pressure measurements can this gauge handle?
A: This gauge is equipped to measure the pressure of gases, with a scale range covering MM WC, CM, PAC, KPA, INCH, and PSI, allowing for versatile use across different processes and industries.
Q: When should I recalibrate or check the gauge for accuracy?
A: It's recommended to periodically verify and recalibrate the gauge, typically every 6 to 12 months, or as specified by your site's standard operating procedures, especially if used in critical applications or exposed to fluctuating temperatures and pressures.
Q: Where is this pressure gauge commonly used?
A: The GEMTECH Differential Pressure Gauge is commonly found in pharmaceutical plants, power plants, cement and steel factories, fertilizer production, and textile industries throughout India and globally, due to its reliability and adaptability.
Q: What is the process for reading the gauge display?
A: To read the gauge, simply observe the analog pointer relative to the calibrated scale on the 4-inch dial. Choose the required measurement unit and record the value where the pointer lands, ensuring the dial face is clean and the pointer is visible for accurate interpretation.
Q: How does using this gauge benefit industrial operations?
A: Accurate and timely pressure measurement helps prevent equipment failure, ensure worker safety, optimize process efficiency, and comply with industry standards, ultimately reducing downtime and enhancing productivity across all applications.
Q: What maintenance does the GEMTECH Differential Pressure Gauge require?
A: Routine maintenance includes checking for leaks, ensuring no physical or chemical damage, cleaning the dial face, and periodically recalibrating the gauge to maintain accuracy and longevity in demanding environments.