About GEMTECH Differential Pressure Gauge From Additional Jejuri Industrial Area Pune

GEMTECH Differential Pressure Gauge From Additional Jejuri Industrial Area Pune
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure, differential pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime, They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely. The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70???(21??????(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges. Minimum is 0-60 Pa And Maximum is 0-21-KPa.
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct, Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
| Model |
Description |
| G2300-0 |
Differential Pressure Gage, Range 0.25-0-0.25" w.c., Minor Divisions .01, Calibrated For Vertical Scale Position. |
| G2301 |
Differential Pressure Gage, Range 0.5-0-0.5" w.c., Minor Divisions .02. |
| G2302 |
Differential Pressure Gage, Range 1-0-1" w.c., Minor Divisions .05. |
| G2304 |
Differential Pressure Gage, Range 2-0-2" w.c., Minor Divisions .10. |
| G2310 |
Differential Pressure Gage, Range 5-0-5" w.c., Minor Divisions .20. |
| G2320 |
Differential Pressure Gage, Range 10-0-10" w.c., Minor Divisions .50. |
| G2330 |
Differential Pressure Gage, Range 15-0-15" w.c., Minor Divisions 1.0. |
Additional Information:

Versatile Measurement for Critical EnvironmentsGEMTECH Differential Pressure Gauge is engineered for precise pressure readings, especially within sensitive pharmaceutical settings. Compatible with various pressure units, its analog display ensures quick, reliable monitoring. This device's robust construction and broad measurement capability make it suitable for a range of industrial applications where accuracy and dependability are paramount.
Built for Accuracy and DurabilityFeaturing a metal alloy body and high-visibility plastic dial, the gauge withstands demanding environments while maintaining 2% full-scale accuracy (other accuracies apply to specific ranges). Designed for long-term performance at 70F (21.1C), its back mount and NPT threading allow easy installation in new or existing systems.
FAQ's of GEMTECH Differential Pressure Gauge From Additional Jejuri Industrial Area Pune:
Q: How is the GEMTECH Differential Pressure Gauge installed?
A: The gauge is designed for a convenient back mount and uses an NPT 1/8 inch thread, which is commonly found in industrial setups. Installation involves securely attaching the gauge to compatible connection points on your system, ensuring tight sealing for accurate pressure detection.
Q: What are the main applications of this differential pressure gauge?
A: This gauge is primarily used in pharmaceutical industries for monitoring gas pressure, but it's also suitable for other industrial applications that require precise measurement of differential pressure, thanks to its robust construction and versatile scale ranges.
Q: When should I consider using a differential pressure gauge like this one?
A: Use this gauge whenever accurate monitoring of pressure differences is required, especially in environments where maintaining specific gas pressures is essential for safety or quality control, such as cleanrooms or process lines in pharmaceutical plants.
Q: Where can this gauge be utilized within a facility?
A: The GEMTECH Differential Pressure Gauge can be installed directly on equipment, pipelines, cleanroom walls, or ventilation systems wherever there is a need to measure the pressure difference across filters, pumps, or other process units.
Q: What is the process to ensure measurement accuracy with this gauge?
A: For best performance, install the gauge on a stable, vibration-free surface using correct threading. Calibrate periodically according to manufacturer instructions and operate at 70F (21.1C) when possible, as the device's full range accuracy is specified at this temperature.
Q: How does using this gauge benefit my operations?
A: By providing reliable, real-time pressure differential readings, this gauge helps ensure process consistency, equipment safety, and regulatory compliance. Its clear analog display and robust construction contribute to easier maintenance and reduced downtime.