About Dwyer DM-005 DigiMag Differential Pressure Transmitter Range 0-2 Inch WC

Dwyer DM-005 DigiMag Differential Pressure Transmitter Range 0-2 Inch WC
Senses The Pressure of Air and Compatible Gases, This Differential Pressure Transmitter Features a Pressure Range of 2 inWC and Has a 4 to 20 mA output. Fast and Easy to Set up, This Transmitter is Suitable for Fan Control, Static Pressures in ducts or buildings, room Pressurization Monitoring, and Differential Pressure Across Filters.
Dwyer DM-005 Offers
Specifically Designed to Mount in a standard Magnehelic Gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.
Features
- Reduced installation time through zero and span controls that provides quick and easy calibration
- Fast and easy setup and calibration with push-button zero and span controls
- Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
- Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic Gauge, as both use the same diameter cutout
Applications
- Differential Pressure Across Filters
- Fan Control
- Static Pressures in Ducts or Buildings
- Room Pressurization Monitoring
Dwyer DM-005 Specifications
| Service |
Air And Non-Combustible, Compatible Gases |
| Pressure Range |
2 inWC |
| Accuracy |
1% FSO |
| Stability |
<1%/year FSO |
| Limits |
Pressure: 3.6 psi maximum operation, 6 psi burst Temperature: -4 to 158F (-20 to 70C) |
| Thermal Effect |
0.02% FS/F (0.036% FS/C) |
| Output Signal |
4 to 20 mA (2-wire) |
| Zero and Span Adjustments |
Push-button |
| Loop Resistance |
0 to 1250 I maximum |
| Current Consumption |
21 mA maximum |
| Connections |
Electrical: Screw-type terminals Process: Male ports on side for ", 316", 14", 0.2" (5 mm), 0.23" (6 mm) ID flexible tubing |
| Power Requirements |
10 to 35 V DC (2-wire) |
| Enclosure Rating |
NEMA 4X (IP66) |
| Mounting Orientation |
Not sensitive to position |
| Agency Approvals |
CE |
| Housing Material |
Polycarbonate |
| Dimensions |
5 x 1.9" (127 x 48.2 mm) |
| Weight |
7.04 oz (200 g) |
Click Here For Complete Specifications On The
Dwyer DM-005What's included with the Dwyer DM-005
- Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC
Additional Information:
- Item Code: DM-005-DigiMag-DP-Transmitter-Range-0-2-Inch-WC
- www.envirotechdelhi.info
- www.envirotechindia.info
- www.envirotechindustrialproducts.info

Versatile Application Across Industries
Dwyer DM-005 excels in diverse environments, supporting pressure monitoring in power generation, cement production, steel manufacturing, fertilizers, and textiles. Its adaptability ensures consistent performance whether installed in demanding or routine conditions, offering precise data for process optimization.
Intuitive Display and Scale Options
Equipped with a large 4-inch dial and multiple pressure unit scales (MM WC, CM, Pa, KPA, INCH), this transmitter provides clear and flexible readings. The YAS display simplifies on-site analysis, while durable plastic construction ensures longevity in industrial applications.
FAQ's of Dwyer DM-005 DigiMag Differential Pressure Transmitter Range 0-2 Inch WC:
Q: How is the Dwyer DM-005 DigiMag Differential Pressure Transmitter typically installed?
A: This transmitter is designed for back mounting and fits seamlessly into most control panels or monitoring stations. Its compact 4-inch diameter dial allows straightforward placement in both new and existing setups, making installation quick across multiple industries.
Q: What types of gases can the DM-005 measure pressure for?
A: The Dwyer DM-005 is suitable for measuring differential pressure of air and non-corrosive gases, making it a reliable choice for a wide range of industrial applications such as HVAC, process control, and clean rooms.
Q: When should you use the DM-005 in your monitoring system?
A: This transmitter is ideal whenever accurate low-pressure measurement of gas is required, particularly between 0-2 inches WC. Common scenarios include monitoring filtration systems, ensuring safe operating conditions, and tracking airflow performance in industrial plants.
Q: Where can this transmitter be effectively utilized?
A: The DM-005 is used extensively in power plants, cement and steel industries, fertilizer manufacturing, and textile plants across India. Its robust design offers dependable performance even in tough plant environments.
Q: What is the benefit of the DM-005's multiple scale display?
A: The transmitter's dial features scales in MM WC, CM, Pa, KPA, and INCH, allowing operators to read pressure in their preferred measurement unit. This flexibility makes integration with existing systems and operator preferences effortless.
Q: How does the DM-005 ensure accurate pressure measurement?
A: With an accuracy of 1% of Full Scale Output (FSO), the DM-005 delivers reliable differential pressure readings. Its standard processing type and high-quality components minimize error and false readings, supporting process safety and efficiency.