Dwyer 1910-00 Compact Low Differential Pressure Switch
Range 0.07 - 0.15" W.C.
Most popular SERIES 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20" w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.
Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.
Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.
| MANUFACTURER | Dwyer |
|---|---|
| PART NUMBER | 1910-00 |
| SHORT DESCRIPTION | 1910-00 - SPDT Compact Low Differential Pressure Switch with Conduit, Range 0.07-0.15" w.c., 1/8" FNPT, Conduit Enclosure |
| PRODUCT SERIES | 1900 Series |
| NOMINAL OR PRIMARY VOLTAGE | 120-277 VAC |
| AMPERAGE RATING | 15A |
| SET POINT/SET POINT RANGE | 0.07-0.15" w.c. |
| INPUT(S) | Resistive 1/8 HP at 125 VAC, 1/4 HP at 250 VAC |
| CONTACT | SPDT |
| CONNECTION | Process Connection: 1/8" FNPT; Electrical Connection: 3 Screw Type, Common, Normally Open and Normally Closed |
| PRESSURE RANGE | 45" w.c. (11.2 kPa) Continuous; 10 psig (68.95 kPa) Surge |
| MAX TEMPERATURE | -30 to 180F |
| FREQUENCY | 60 Hz |
| APPLICATIONS | For Air Conditioning Refrigeration Coil Icing Detection, Defrost Cycle Intiation, Clogged Filter Detection, Variable Air Volume Controller, Air and Non-Combustible, Compatible Gases |
| STANDARDS/APPROVALS | CE Approved, CSA, FM, UL, RoHS Complaint |
| ADDITIONAL PRODUCTS OR REQUIREMENTS | A-399, A-329, A-489, A-302F-A |

Price:
Function : Detects and switches on/off at selected pressure differential
Max. Current : 15 A resistive @ 125/250/480 VAC
Pressure Range : 4.020.0 w.c. (1050 mbar)
Application : Monitoring and controlling air filters, fans, blowers, and duct systems
Working Temperature : 30 to 150F (34 to 65C)
Output Signal : SPDT Snap Switch
Function : Differential Pressure Sensing & Switching
Max. Current : 15 A @ 125, 250 or 480 VAC
Pressure Range : 0.07 to 20 w.c. (17.4 to 4,982 Pa)
Application : HVAC, air handlers, filter monitoring, duct static pressure, fan and blower equipment
Working Temperature : 20 to 85 C
Output Signal : SPDT snap switch
Function : Differential pressure sensing
Max. Current : 15 A @ 125/250 VAC (Resistive)
Pressure Range : 1.4 5.5 W.C. (Water Column)
Application : Air and noncombustible gas flow monitoring, air filter monitoring, duct static pressure, fan control, damper control
Working Temperature : 40C to 85C
Output Signal : SPDT Snap switch
Function : Monitors and controls low air differential pressure
Max. Current : 15A (SPDT) resistive at 120480 VAC
Pressure Range : 0.03 to 0.2 w.c. (7.5 to 50 Pa)
Application : Air and noncombustible compatible gases
Working Temperature : 30C to 85C
Output Signal : SPDT snap switch