Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75
Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75

Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75" W.C.

Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75" W.C. Specification

  • Working Temperature
  • -40 to 180F (-40 to 82C)
  • Function
  • Pressure switch activates at adjustable set-point
  • Max Pressure
  • psi, 35 mbar
  • Thread size
  • NPT
  • Mechanical Life
  • Over 1,000,000 cycles
  • Product Type
  • Compact Low Differential Pressure Switch
  • Max. Current
  • 15 A resistive @ 125/250/480 V AC
  • Max. Voltage
  • 480 V AC
  • Protection Class
  • IP54
  • Pressure Range
  • 3.0 to 11.75 W.C. (Water Column)
  • Application
  • Monitoring and controlling air and non-combustible gases in ducts, fan, and blower applications
  • Output Signal
  • SPDT (Single-Pole Double-Throw) switch contact
  • Size
  • Compact design, dimensions approx. 2.63 x 2.63 x 1.25 (66.8 mm x 66.8 mm x 31.8 mm)
  • Color
  • Grey
  • Weight
  • Approx. 180 g (based on similar model)
  • Enclosure Material
  • Die-cast aluminum
  • Switch Type
  • Diaphragm actuated, SPDT
  • Electrical Connection
  • Screw terminal
  • Set Point Adjustment
  • External adjustment screw
  • Repeatability
  • 0.1" W.C.
  • Series
  • 1910-10
  • Process Connection
  • Two " NPT female ports
  • Contact Material
  • Silver alloy contacts
  • Suitable Media
  • Air and non-combustible gases
  • Response Time
  • Fast acting switch
  • Mounting Orientation
  • Vertically, with pressure connections pointing downwards
 

Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75" W.C. Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, Middle East, Western Europe, Africa, Central America, Eastern Europe, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75" W.C.

Dwyer 1910-10 Compact Low Differential Pressure Switch.

RANGE 3.0-11.75" W.C.

DESCRIPTION

Most popular SERIES 1900 combines advanced design and precision construction to make these switches able to perform many of the tasks of larger, costlier units. Designed for air conditioning service, they also serve many fluidics, refrigeration, oven and dryer applications. Series 1900 switches have set points from 0.07 to 20" w.c. (1.8 to 508 mm). Set point adjustment is easy with range screw located inside conduit enclosure. Internal location helps prevent tampering.

Compact size and repeatability, provides a high-value switch for many industrial and OEM applications.

Range screw protected inside enclosure provides simplifies making adjustments but prevents tampering.

MANUFACTURERDwyer
PART NUMBER1910-10
SHORT DESCRIPTION1910-10 - SPDT Compact Low Differential Pressure Switch with Conduit, Range 3.0-11.75" w.c., 1/8" FNPT, Conduit Enclosure
PRODUCT SERIES1900 Series
NOMINAL OR PRIMARY VOLTAGE120-277 VAC
AMPERAGE RATING15A
SET POINT/SET POINT RANGE3.0-11.75" w.c.
INPUT(S)Resistive 1/8 HP at 125 VAC, 1/4 HP at 250 VAC
CONTACTSPDT
CONNECTIONProcess Connection: 1/8" FNPT; Electrical Connection: 3 Screw Type, Common, Normally Open and Normally Closed
PRESSURE RANGE45" w.c. (11.2 kPa) Continuous; 10 psig (68.95 kPa) Surge
MAX TEMPERATURE-30 to 180F
FREQUENCY60 Hz
APPLICATIONSFor Air Conditioning Refrigeration Coil Icing Detection, Defrost Cycle Intiation, Clogged Filter Detection, Variable Air Volume Controller, Air and Non-Combustible, Compatible Gases
STANDARDS/APPROVALSCE Approved, CSA, FM, UL, RoHS Complaint
ADDITIONAL PRODUCTS OR REQUIREMENTSA-399, A-329, A-489, A-302F-A

 



Reliable and Adjustable Pressure Switching

The Dwyer 1910-10 allows external set point adjustment for efficient on-site configuration. With a repeatability of 0.1" W.C., it ensures consistent performance. The diaphragm design and silver alloy contacts provide fast, accurate switching while supporting a wide current range, making it suitable for demanding air and gas monitoring applications.


Compact and Robust Design for Versatile Installations

The devices compact size ensures easy integration into confined spaces. Its durable die-cast aluminum enclosure offers lasting durability and protection (IP54), while the two " NPT female ports facilitate straightforward process connection. Mounting in a vertical orientation with connections facing downward optimizes installation for ductwork and machinery interfaces.

FAQs of Dwyer 1910-10 Compact Low Differential Pressure Switch, RANGE 3.0-11.75" W.C.:


Q: How do I adjust the set point on the Dwyer 1910-10 pressure switch?

A: Set point adjustment is easily accomplished using the external adjustment screw located on the switch housing. This allows you to fine-tune the activation point within the specified range of 3.0 to 11.75" W.C. without disassembling the unit.

Q: What kind of applications is this pressure switch suitable for?

A: The Dwyer 1910-10 is ideal for monitoring and controlling air and non-combustible gases in ventilation ducts, fan systems, and blower applications. Its fast response and high repeatability make it reliable for critical air/gas flow monitoring and control.

Q: When should the pressure connections be oriented downwards?

A: For optimal performance and accurate switching, the pressure switch must be installed vertically with the pressure connections pointing downward, as specified by the manufacturer.

Q: Where can this switch be installed and used in India?

A: As a robust and compact device, the Dwyer 1910-10 can be installed in various commercial and industrial HVAC systems, process plants, and any applications requiring air or non-combustible gas monitoring. It is distributed in India through manufacturers, suppliers, traders, and wholesalers.

Q: What process media is compatible with this switch?

A: This pressure switch is designed specifically for use with air and non-combustible gases. Using other media may damage the sensor or affect accuracy.

Q: What are the primary benefits of using the Dwyer 1910-10 pressure switch?

A: Key benefits include its compact design, rapid response, wide pressure range, durable aluminum housing, reliable SPDT output, and simple external set point adjustment. Its mechanical life exceeds one million cycles, minimizing maintenance and replacement frequency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in 1900 Compact Low Differential Pressure Switches Category

Dwyer 1900 Series Compact Low Differential Pressure Switches

Dwyer 1900 Series Compact Low Differential Pressure Switches

Weight : Approx. 184 g

Thread size : 1/8 female NPT connection

Max. Current : 15 A @ 125, 250 or 480 VAC

Mechanical Life : >1,000,000 cycles

Protection Class : IP54 (with cover) or open type

Max Pressure : 10 psig (0.69 bar)

Dwyer 1920-10 Compact Low Differential Pressure Switch,RANGE 4.0-20.0

Dwyer 1920-10 Compact Low Differential Pressure Switch,RANGE 4.0-20.0" W.C.

Weight : 0.8 lbs (0.36 kg)

Thread size : 1/8 female NPT for pressure connection

Max. Current : 15 A resistive @ 125/250/480 VAC

Mechanical Life : Over 1,000,000 cycles

Protection Class : General Purpose Snap Switch; NEMA 1 Enclosure

Max Pressure : 25 w.c. (62 mbar)

Dwyer 1910-00 Compact Low Differential Pressure Switch, Range 0.07 - 0.15

Dwyer 1910-00 Compact Low Differential Pressure Switch, Range 0.07 - 0.15" W.C.

Weight : 400 grams (approx.)

Thread size : Barbed fittings for 3/16 I.D. tubing

Max. Current : 15A resistive, 1/8 HP at 125 VAC, 1/4 HP at 250 VAC

Mechanical Life : Over 1 million cycles

Protection Class : NEMA 1 (IP20)

Max Pressure : 10 PSI (0.69 bar)

Dwyer 1910-1 Compact Low Differential Pressure Switch, Range 0.40-1.6

Dwyer 1910-1 Compact Low Differential Pressure Switch, Range 0.40-1.6" W.C.

Weight : Approx. 420 g

Thread size : 1/8 female NPT

Max. Current : 15 A @ 125/250/480 VAC; 0.5 A @ 125 VDC; 0.25 A @ 250 VDC

Mechanical Life : One million cycles

Protection Class : IP54 (with cover installed)

Max Pressure : 21 w.c. (5.2 kPa)