Series 4000 Capsuhelic Differential Pressure Gage Specification

  • Display
  • Analog
  • Grade
  • Industrial
  • Sensor Type
  • Capsule (Diaphragm) Differential Pressure Sensor
  • Thread
  • 1/8 NPT Female
  • Outer Size
  • Approx. 4 (101.6 mm) Diameter
  • Seal Material
  • Buna-N
  • Bourdon Tube
  • Not Applicable (Capsule Type)
  • Material
  • Die-cast aluminum case, glass lens, Buna-N diaphragm
  • Dial Material
  • White matte with black markings
  • Pointer Material
  • Black aluminum
  • Processing Type
  • Precision-engineered, factory calibrated
  • Diameter
  • 4 (101.6 mm)
  • Glass Size
  • 4 (101.6 mm) viewing area
  • Mount Type
  • Surface or flush mounting
  • Scale Range
  • 0-0.5 to 0-600 inches of water
  • Accuracy
  • 3% of full scale
  • Finishing
  • Black anodized aluminum case
  • Measure Pressure Of
  • Air and non-corrosive gases
  • Accessories
  • Mounting bracket, screws, and instruction sheet
 

Series 4000 Capsuhelic Differential Pressure Gage Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Western Europe, Africa, Eastern Europe, Middle East, South America, Asia, Central America, North America
  • Main Domestic Market
  • All India
 

About Series 4000 Capsuhelic Differential Pressure Gage

Series 4000 Capsuhelic Differential Pressure Gage

Measures Pressure, Vacuum or Differential, Suitable for Internal Pressures to 500 psig

The SERIES 4000 Capsuhelic gage is designed to give fast, accurate indication of differential pressures. The gage may be used as a readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure, vacuum or differential pressure. The pressure being measured is held within a capsule which is an integral part of the gage. This containment of the pressure permits the use of the gage on system pressures of up to 500 psig, even when differentials to be read are less than 0.1 in w.c.

Product Applications

  • Fluid flow
  • Liquid storage tanks
  • Filter pressure drops
  • Vacuum or differential pressure

 

 ModelDescription 
 4000-0Differential pressure gage, range 0-0.5" w.c., for vertical scale position only. 
 4001Differential pressure gage, range 0-1.0" w.c., for vertical scale position only. 
 4002Differential pressure gage, range 0-2.0" w.c., for vertical scale position only. 
 4003Differential pressure gage, range 0-3.0" w.c., for vertical scale position only. 
 4004Differential pressure gage, range 0-4.0" w.c., for vertical scale position only. 
 4005Differential pressure gage, range 0-5.0" w.c., for vertical scale position only. 
 4006Differential pressure gage, range 0-6.0" w.c. 
 4008Differential pressure gage, range 0-8.0" w.c. 
 4010Differential pressure gage, range 0-10" w.c. 
4015 Differential pressure gage, range 0-15" w.c. 
 4020Differential pressure gage, range 0-20" w.c. 
 4025 Differential pressure gage, range 0-25" w.c.
 4030Differential pressure gage, range 0-30" w.c. 
 4040Differential pressure gage, range 0-40" w.c. 
4050 Differential pressure gage, range 0-50" w.c. 
 4060 Differential pressure gage, range 0-60" w.c.
 4080Differential pressure gage, range 0-80" w.c. 
 4100 Differential pressure gage, range 0-100" w.c.
 4150Differential pressure gage, range 0-150" w.c. 
 4200Differential pressure gage, range 0-200" w.c. 
4300 Differential pressure gage, range 0-300" w.c. 
4400 Differential pressure gage, range 0-400" w.c. 
 4500Differential pressure gage, range 0-500" w.c. 
 


 

 



Rugged Construction for Demanding Environments

Designed with black anodized die-cast aluminum and a durable acrylic lens, the Series 4000 Capsuhelic Gage stands up to harsh industrial conditions. Its external zero adjustment screw allows for swift recalibration without dismantling, ensuring accuracy and minimal downtime during routine maintenance.


Versatile Mounting and Connection Options

Whether you require surface or flush mounting, the Series 4000 Gage offers flexible installation. Side and back 1/8 NPT female connections let you adapt the gage to various piping arrangements, simplifying integration into existing or new systems for air and non-corrosive gas measurements.


Simple, Reliable Analog Operation

With no external power required, the mechanical Capsule (Diaphragm) Differential Pressure Sensor delivers real-time readings via a clear analog display. Its factory calibration and 3% full-scale accuracy make it a dependable solution for differential pressure monitoring in industrial setups.

FAQs of Series 4000 Capsuhelic Differential Pressure Gage:


Q: How is the Series 4000 Capsuhelic Differential Pressure Gage installed?

A: You can mount the gage either on a surface or flush with a panel, utilizing the included mounting bracket and screws. Side and back 1/8 NPT female connections offer flexibility for setup in various orientations and system layouts.

Q: What types of media can the gage safely measure?

A: The Series 4000 Capsuhelic Differential Pressure Gage is engineered for monitoring the differential pressure of air and other non-corrosive gases. Its not intended for liquids or corrosive media.

Q: When should I use the external zero adjustment screw?

A: The external zero adjustment screw allows you to recalibrate the gauge if you notice a drift from true zero, helping maintain measurement accuracy over time. This process can be completed without disassembling the device.

Q: Where can I use the Series 4000 Capsuhelic Gage in my facility?

A: This gage is suitable for diverse industrial settings, including HVAC systems, filter monitoring, clean rooms, and process control for air and gas applications, wherever precise differential pressure monitoring is needed.

Q: What are the benefits of using a mechanical gage without power requirements?

A: Because it operates mechanically, the Capsuhelic gage requires no electrical power, enhancing reliability and reducing installation complexity. This feature also makes it suitable for locations without easy access to power sources.

Q: How accurate is the Series 4000 Capsuhelic Differential Pressure Gage?

A: The gage offers an accuracy of 3% of full scale, with factory calibration ensuring precise readings for industrial monitoring and control tasks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series 4000 Capsuhelic Differential Pressure Gage Category

Dwyer 4020 Capsuhelic Differential Pressure Gauge

Dwyer 4020 Capsuhelic Differential Pressure Gauge

Price 9871034100 INR

Minimum Order Quantity : 12 Pieces

Diameter : 4 inches (101.6 mm)

Glass Size : Approximately 4 inches (matches case diameter)

Scale Range : 010 in H2O

Seal Material : Silicone Rubber

Dwyer 4030 Capsuhelic Differential Pressure Gauge

Dwyer 4030 Capsuhelic Differential Pressure Gauge

Price 9871034100 INR

Minimum Order Quantity : 12 Pieces

Diameter : 4 (100 mm)

Glass Size : Full cover, clear acrylic lens

Scale Range : 030 inches of water gauge (inH2O)

Seal Material : Silicone rubber gaskets

Dwyer 4003 Capsuhelic Differential Pressure Gauge

Dwyer 4003 Capsuhelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 inch nominal

Glass Size : Full Front Cover Size

Scale Range : 03 Inches w.c. (Water Column)

Seal Material : Neoprene

Dwyer 4050 Capsuhelic Differential Pressure Gauge

Dwyer 4050 Capsuhelic Differential Pressure Gauge

Price 9871034100 INR

Minimum Order Quantity : 12 Pieces

Diameter : 41/2 inch (114 mm)

Glass Size : 4 inch window

Scale Range : 015 psi (or as specified)

Seal Material : BunaN