Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar Specification

  • Thread
  • G1/8 (Female)
  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure Sensor
  • Display
  • Digital
  • Outer Size
  • 101.6 mm x 80 mm x 56 mm
  • Seal Material
  • Silicone
  • Material
  • ABS Housing
  • Dial Material
  • ABS Plastic
  • Processing Type
  • Electronic
  • Diameter
  • 101.6 mm
  • Mount Type
  • Panel / Wall Mount
  • Scale Range
  • -1.25 to +1.25 mbar
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • Matte
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Bracket, Installation Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



High-Precision Differential Pressure Measurement

Engineered for industrial excellence, the DPT1-R8 ensures accurate detection of air and non-corrosive gas pressure differences. With its narrow measurement range, high accuracy (1% of full scale), and long-term stability, it is ideal for sensitive pressure monitoring applications. The digital display and rapid response time streamline real-time data capture and system integration.


Durable Construction and Versatile Installation

Housed in resilient ABS plastic with a matte finish, the transmitter is IP65-rated for protection against dust and moisture. The brass pressure ports and robust silicone seals enhance longevity. Versatile mounting optionsincluding panel and wallfacilitate easy installation in diverse industrial setups. Accessories like the mounting bracket and installation manual are included.


User-Friendly Operation and Maintenance

The DPT1-R8 features intuitive zero adjustment via a front-mounted button, enabling quick recalibration. Electrical connections are simplified with a terminal block, while the clear digital display aids in direct monitoring. Its electronic processing ensures reliable performance, backed by straightforward maintenance and minimal downtime.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar:


Q: How is the Sensocon DPT1-R8 differential pressure transmitter typically installed?

A: The DPT1-R8 can be securely mounted on panels or walls using the supplied mounting bracket. Its G1/8 (female) threads facilitate easy connection to pressure lines, while the compact size allows for flexible placement in industrial settings.

Q: What types of media can the DPT1-R8 accurately measure?

A: The transmitter is specifically designed to measure differential pressure of air and other non-corrosive gases, making it suitable for applications such as HVAC systems, cleanrooms, and ventilation monitoring.

Q: When is zero adjustment necessary, and how do you perform it?

A: Zero adjustment is recommended during initial setup or after prolonged use to maintain measurement accuracy. It is easily done via the front-mounted button on the transmitter, allowing for hassle-free recalibration without external tools.

Q: Where can the DPT1-R8 operate effectively in terms of environmental conditions?

A: With an operating temperature range of -5C to +60C and an IP65 protection class, the transmitter performs reliably in typical indoor industrial environments, including areas exposed to dust or moisture.

Q: What is the benefit of the devices fast response time?

A: A response time of less than 50 ms allows the DPT1-R8 to capture and transmit rapid changes in pressure, which is essential for real-time monitoring and control in dynamic industrial processes.

Q: How is the electrical connection established for the DPT1-R8?

A: The transmitter features a terminal block connection for straightforward wiring to control systems, operating at 24 VDC and providing a standard 4-20 mA output signal compatible with most industrial monitoring and automation systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 380 mmWC

Mount Type : Other, Wall Mount

Accessories : Mounting Bracket, User Manual

Measure Pressure Of : Other, Air and NonCorrosive Gases

Sensor Type : Differential Pressure Transmitter

Display : Digital LCD Display

Outer Size : Approx. 120mm x 92mm x 52mm (H x W x D)

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -64 - 64 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -64 - 64 mmWC

Mount Type : Other, Panel or Surface Mount

Accessories : Mounting Screws, Installation Manual

Measure Pressure Of : Other, Air, Noncorrosive Gases

Sensor Type : Differential Pressure Transmitter

Display : Digital

Outer Size : 124 mm x 84 mm x 55 mm (L x W x D)

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -5.0 - 5.0 inWC

Mount Type : Other, Wall or Duct Mount

Accessories : Bracket, Manual, Mounting Screws

Measure Pressure Of : Other, Air and Noncorrosive Gases

Sensor Type : Differential Pressure Transmitter

Display : Digital

Outer Size : Standard compact housing

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Mount Type : Other, Wall / Panel Mount

Accessories : Mounting Bracket, Manual, Calibration Certificate

Measure Pressure Of : Other, Air and NonCorrosive Gases

Sensor Type : Differential Pressure Transmitter

Display : Without Display

Outer Size : 92 mm x 92 mm x 53 mm (Approx.)



Back to top