Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 25 Pa
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 25 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 25 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 25 Pa Specification

  • Display
  • None (Transmitter Output)
  • Thread
  • No Threaded Connection (Tube Connectors)
  • Seal Material
  • Silicone
  • Grade
  • Industrial Grade
  • Outer Size
  • Approx. 90 x 66 x 36 mm
  • Sensor Type
  • Differential Pressure Transmitter
  • Material
  • ABS (Housing), Silicone (Sensor)
  • Processing Type
  • Electronic
  • Mount Type
  • Wall / Surface Mount
  • Scale Range
  • 0 - 25 Pa
  • Accuracy
  • 1% of Full Scale
  • Finishing
  • ABS Plastic Housing
  • Measure Pressure Of
  • Air and Non-Corrosive Gases
  • Accessories
  • Mounting Screws, Instruction Manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 25 Pa Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Middle East, Western Europe, Africa, Central America, Eastern Europe, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 25 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 25 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision Measurement for Sensitive Applications

The DPT1-R8 excels at measuring minimal differential pressures in air and non-corrosive gas systems, boasting 1% full scale accuracy. This precision makes it ideal for cleanrooms, filter monitoring, and ventilation systems. Its quick response time and adjustable output signal ensure reliable and real-time data for optimal environmental control.


Flexible Installation and Easy Operation

Engineered for flexibility, the transmitter can be mounted on any wall or surface and accepts connections via tube connectors. Zero and span adjustments are simple, thanks to a built-in potentiometer. The ABS housing provides durability, while its IP54 protection guards against dust and splashes, ensuring longevity in demanding environments.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 25 Pa:


Q: How do I install the Sensocon Series DPT1-R8 Differential Pressure Transmitter?

A: The device is designed for wall or surface mounting using the supplied screws. Ensure it is connected to appropriate air or dry gas lines using the tube connectors, and wire the power supply and output via the screw terminals as per the instruction manual.

Q: What media is compatible with the DPT1-R8 pressure transmitter?

A: This transmitter is suitable exclusively for measuring air and dry, non-corrosive gases. It should not be exposed to liquids, corrosive, or humid gases to maintain accuracy and longevity.

Q: When should I adjust the zero and span settings?

A: Zero and span adjustments should be made during initial setup or after maintenance, using the potentiometer to ensure the output matches actual pressure conditions. Consult the manual for guidance.

Q: Where can I use the Series DPT1-R8 in industrial settings?

A: The transmitter is ideal for monitoring filters, duct static pressure, or cleanroom applications. Its 025 Pa range suits environments where precise, low-pressure differential measurement is crucial.

Q: What is the benefit of the selectable 010 VDC / 420 mA output?

A: Selectable output signals offer flexibility, allowing compatibility with a broad range of controllers, data loggers, or building automation systems commonly used in industrial and HVAC applications.

Q: How does the IP54 protection rating enhance its performance?

A: The IP54 rating ensures the transmitter has adequate protection against dust ingress and water splashes, making it reliable for use in industrial and commercial environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Series DPT1-R8 - Range -62 - 62 Pa

Sensocon USA Series DPT1-R8 - Range -62 - 62 Pa

Accuracy : 1.0% of F.S.

Scale Range : 62 to +62 Pa

Processing Type : Other, Electronic

Thread : 1/8 NPT

Accessories : Mounting screws, Installation manual

Finishing : Other, ABS Plastic Housing

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Accuracy : 1% F.S.

Scale Range : 0.62 to 0.62 mbar

Processing Type : Other, Microprocessor Based

Thread : G1/8 (Female)

Accessories : Mounting bracket, Calibration certificate, Instruction Manual

Finishing : Other, IP65 Rated Enclosure

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -5.0 - 5.0 inWC

Accuracy : 1% of Full Scale

Scale Range : 5.0 to 5.0 inWC

Processing Type : Other, Digital Electronic

Thread : 1/8 NPT Female

Accessories : Mounting Bracket Included, Instruction Manual

Finishing : Other, Powder Coated Housing

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Accuracy : 1.0% of Full Scale

Scale Range : 0.5 to 0.05 in WC

Processing Type : Other, Microprocessor Controlled

Thread : 1/8 NPT Female

Accessories : Mounting Screws, Manual

Finishing : Other, Matte ABS Casing



Back to top