Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.25 - 0.25 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.25 - 0.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar Specification

  • Thread
  • 6 mm hose connection
  • Grade
  • Industrial
  • Outer Size
  • Approx. 90 x 90 x 36 mm
  • Seal Material
  • Silicone
  • Display
  • Analog
  • Sensor Type
  • Differential Pressure Sensor
  • Material
  • ABS plastic, polycarbonate front
  • Dial Material
  • Polycarbonate
  • Pointer Material
  • Plastic
  • Processing Type
  • Electronic
  • Diameter
  • 90 mm
  • Mount Type
  • Wall Mount
  • Scale Range
  • -0.25 to 0.25 mbar
  • Accuracy
  • 1% F.S.
  • Finishing
  • ABS plastic housing, white finish
  • Measure Pressure Of
  • Air and non-corrosive gases
  • Accessories
  • Mounting screws, installation manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, Central America, Eastern Europe, Western Europe, Middle East, Africa, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.25 - 0.25 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



High Accuracy Differential Pressure Measurement

The DPT1-R8 delivers precise monitoring with a capacitive sensor and 1% full scale accuracy. Its analog display and clear 90 mm dial enable quick data interpretation for sensitive air and gas pressure applications in industrial environments.


Reliable and Durable Industrial Construction

Featuring an ABS plastic housing with a polycarbonate front, the transmitter is IP65 rated for dust and moisture resistance. Designed for wall mounting, it comes complete with all essential accessories and installation manual, ensuring a secure set-up in demanding locations.


Versatile Application in HVAC and Clean Rooms

This transmitter is engineered for HVAC systems, air handling units, filter condition monitoring, and clean room pressure management. With the flexibility to gauge differential pressure of air and non-corrosive gases, it supports a wide range of process control requirements.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.25 - 0.25 mbar:


Q: How is the Sensocon DPT1-R8 differential pressure transmitter installed?

A: The transmitter is designed for wall mounting and includes mounting screws and an installation manual. Electrical connections are made using the screw terminal block, and hose connections utilize 6 mm threads.

Q: What types of gases can this transmitter measure?

A: The DPT1-R8 is suitable for measuring differential pressure in air and other non-corrosive gases, making it ideal for clean room environments, HVAC systems, and air handling processes.

Q: When should I perform zero adjustment on this device?

A: Manual zero adjustment should be conducted using the potentiometer before initial operation or after significant changes in installation conditions, ensuring accurate baseline measurement.

Q: Where can the DPT1-R8 transmitter be utilized?

A: This device is most commonly used in industrial settings, specifically for HVAC, air handling units, filter monitoring, and clean rooms where precise pressure measurement is essential.

Q: What is the process for setting up the electrical connections?

A: Connect the power supply (24 VDC) and output signal (2-wire, 4-20 mA) to the screw terminal block as per the instructions provided in the installation manual. Ensure secure and correct wiring for optimal performance.

Q: How does the transmitter benefit HVAC and clean room applications?

A: It provides accurate real-time monitoring of small pressure differentials, ensuring proper air flow, filter maintenance, and contamination control, thereby supporting efficient system operation and compliance with standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -1250 - 1250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -1250 - 1250 Pa

Display : Digital LCD

Sensor Type : Differential Pressure Transmitter

Processing Type : Other, Electronic Measurement

Accessories : Mounting Bracket, Instruction Manual

Thread : 1/8 NPT Female

Finishing : Other, Anodized Aluminum

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC

Display : No display (Transmitter only)

Sensor Type : Differential Pressure Transmitter

Processing Type : Other, Electronic

Accessories : Mounting Screws, Installation Manual

Thread : 1/8 NPT Female Ports

Finishing : Other, ABS Plastic Housing

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 2500 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 2500 Pa

Display : Digital

Sensor Type : Differential Pressure Transmitter

Processing Type : Other, Electronic

Accessories : Mounting Screws, User Manual

Thread : 1/8 NPT Female

Finishing : Other, ABS Plastic Enclosure

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -15.0 - 15.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -15.0 - 15.0 inWC

Display : 4digit LCD Display

Sensor Type : Differential Pressure Transmitter

Processing Type : Other, Electronic Sensor

Accessories : Mounting kit, Instruction manual

Thread : 1/8 NPT Female

Finishing : Other, Matte finish polycarbonate housing



Back to top