Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 12.7 mmWC Specification

  • Sensor Type
  • Differential Pressure Transmitter
  • Seal Material
  • Silicone or NBR
  • Grade
  • Industrial
  • Display
  • No integrated display
  • Outer Size
  • Compact enclosure (specific dimension not stated)
  • Material
  • ABS Plastic/Aluminum Housing
  • Processing Type
  • Electronic
  • Diameter
  • Not applicable (transmitter type)
  • Mount Type
  • Wall/Panel mount
  • Scale Range
  • 0 - 12.7 mmWC
  • Accuracy
  • 1% of F.S.
  • Finishing
  • Powder-coated/Anodized finish
  • Measure Pressure Of
  • Air and non-corrosive gases
  • Accessories
  • Mounting screws, user manual
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 12.7 mmWC Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Western Europe, Africa, Central America, South America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 12.7 mmWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision and Reliability for Industrial Applications

Designed specifically for HVAC, filter monitoring, and clean room environments, the DPT1-R8 delivers precise differential pressure readings. Its sturdy construction, advanced electronics, and effective sealing ensure consistent performance even in demanding conditions, supporting critical building automation processes.


Effortless Installation and Adjustment

The transmitter features a compact enclosure and easy mounting, with a 1/8" NPT female pressure connection for straightforward integration. Zero and span adjustments can be accessed via an external potentiometer, allowing users to fine-tune performance without complex tools or procedures.


Robust Construction for Long-Term Use

With an IP54-rated housing made from ABS plastic and anodized aluminum, the DPT1-R8 stands up to challenging industrial environments. The powder-coated finish enhances resistance to wear, and the silicone or NBR seal materials ensure reliable operation with air and non-corrosive gases.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 12.7 mmWC:


Q: How is the Sensocon DPT1-R8 differential pressure transmitter installed?

A: The DPT1-R8 can be wall or panel-mounted using the provided mounting screws. Electrical connections are made via a terminal block, and the pressure ports utilize 1/8" NPT female fittings for easy integration into air handling systems.

Q: What type of output signal does the DPT1-R8 provide for system integration?

A: The device offers a standard 420 mA output signal (2-wire configuration), which supports seamless integration with most industrial control systems and building automation platforms.

Q: When should I consider zero/span adjustment and how is it performed?

A: Zero and span adjustment may be necessary during commissioning or routine maintenance to ensure accurate readings. Adjustments are made easily using the accessible potentiometers on the transmitters body, without specialized equipment.

Q: Where can this transmitter be used within an industrial or commercial setting?

A: It is ideal for HVAC applications, filter monitoring, clean rooms, and building automation where accurate differential pressure measurement of air or non-corrosive gases is essential.

Q: What is the process for connecting the pressure measurement ports?

A: Connect the air or non-corrosive gas lines to the 1/8" NPT female pressure ports. Ensure the seals (silicone or NBR) are properly seated for leak-free operation before powering on the unit.

Q: How does the DPT1-R8s fast response time benefit my application?

A: With a response time of less than 50 ms, the transmitter quickly detects pressure changes, making it suitable for dynamic environments where immediate feedback is necessary for system control and safety.

Q: What are the advantages of using the DPT1-R8 in building automation?

A: The transmitters accuracy, reliability, and compact design make it ideal for monitoring and controlling air pressure differentials, supporting energy efficiency, indoor air quality, and equipment protection in automated building systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series DPT Differential Pressure Transmitter India Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25.4 mmWC

Scale Range : 0 25.4 mmWC

Processing Type : Other, Electronic

Accuracy : 1% of Full Scale

Seal Material : Nitrile Rubber (Standard)

Sensor Type : Differential Pressure Transmitter

Outer Size : 92 mm x 92 mm x 53 mm (Approx.)

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar

Scale Range : 0 0.62 mbar

Processing Type : Other, Pressure Sensing Electronic

Accuracy : 2% of full scale

Seal Material : Silicone (for ports)

Sensor Type : Differential Pressure Transmitter

Outer Size : 115 mm x 90 mm x 57 mm (approx.)

Sensocon USA Series DPT1-R8 - Range 0 - 0.1 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.1 in WC

Scale Range : 0 0.1 in WC

Processing Type : Other, Electronic

Accuracy : 1.0% of FS

Seal Material : EPDM

Sensor Type : Differential Pressure Sensor

Outer Size : 117 x 117 x 40 mm (Approx.)

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Scale Range : 12.5 to 12.5 mbar

Processing Type : Other, Electronic

Accuracy : 1% of span

Seal Material : Silicone

Sensor Type : Differential Pressure Transmitter

Outer Size : Compact Housing



Back to top