Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa
Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa Specification

  • Display
  • None (Switch Type)
  • Sensor Type
  • Differential Pressure Switch
  • Seal Material
  • Silicon, NBR
  • Grade
  • Industrial Grade
  • Outer Size
  • Approx. 105 mm x 85 mm x 58 mm
  • Thread
  • G1/8 (female), push-on connection
  • Material
  • ABS Housing
  • Processing Type
  • OEM, Standard
  • Mount Type
  • Wall Mounting
  • Scale Range
  • 50-500 Pa
  • Accuracy
  • 1.5% F.S.
  • Finishing
  • ABS Enclosure, Flame Retardant
  • Measure Pressure Of
  • Air and Non-Aggressive Gases
  • Accessories
  • Mounting screws, installation manual
 

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa

Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa


Model NumberPressure range in w.c. (Pa)
104-20.20 to 2.00 (50-500 Pa)

The Series 104 Differential Pressure Switch is a low-cost easy to use differential pressure switch for very low pressure applications. The differential pressure switch can monitor positive, negative, or differential pressure and with an easy to adjust set point knob makes field set up and adjustment hassle free. The differential pressure switch includes a SPDT relay rated for2A @ 250V and can be set as low as 0.08 w.c. (20 Pa).

Specification

Media:Air and compatible gases Max Pressure:20" w.c. (5000 Pa)Temperature Limits:5 to 140F (-15 to 60C)Electrical Rating:2A @ 250 V Electrical Connection:Screw terminals Process Connection:3/16" I.D. flexible tubing Enclosure Rating:NEMA 13 (IP 54)Weight:3.5 oz (100 g)Accessories:6 ft (1.8m) flexible tubing, (2) Static pressure fittings, C type mounting bracket, and mounting screws Repeatability:2%Dead band:approximately 10% of max set point



Durable Design and Easy Installation

The Series 104 - 2 Differential Pressure Switch is engineered with an ABS enclosure that is both flame-retardant and resistant to the challenges of industrial environments. The IP54 rating ensures dust and splash protection, and mounting is streamlined thanks to included hardware and clear instructions. Its compact dimensions allow for straightforward wall mounting in a variety of settings.


Wide Pressure Range and High Accuracy

With a scalable pressure range from 50 to 500 Pa and an accuracy of 1.5% F.S., this switch delivers dependable performance in monitoring air and non-aggressive gases. Adjustable hysteresis ensures flexibility for different application requirements, while the devices passive operation guarantees straightforward integration into your existing system.


Electrical Reliability and Safety

The Series 104 - 2 features SPDT (Single Pole Double Throw) contacts with a switching capacity of 5A at 250VAC or 30VDC (resistive load), making it suitable for a broad array of industrial control circuits. Screw terminal connections support secure wiring, and the switch is certified with CE marking to meet European safety standards.

FAQs of Sensocon USA Differential Pressure Switch Series 104 - 2 Pressure Range 50-500 Pa:


Q: How do I install the Sensocon 104 - 2 differential pressure switch in my system?

A: The switch is designed for easy wall mounting. It comes with mounting screws and a detailed installation manual. Simply secure the switch to a suitable wall surface and connect air or non-aggressive gas lines using the G1/8 female or push-on connectors, then complete the wiring through the provided screw terminals.

Q: What types of media can this pressure switch be used with?

A: The Series 104 - 2 is suitable for measuring differential pressure of air and non-aggressive gases only. Avoid using it with corrosive, aggressive, or liquid media, as this could damage the internal components and seals.

Q: When is it beneficial to use a differential pressure switch without a power supply?

A: Since the Sensocon 104 - 2 is a passive device, it does not require an external power source to function, making it particularly useful in applications where electrical power is limited or conservation is needed, and in fail-safe switching scenarios.

Q: Where can I use the Sensocon Series 104 - 2 in an industrial environment?

A: Typical applications include HVAC monitoring, air filter checks, cleanroom pressure control, and process automation systems involving air flow or ventilation. Its robust IP54 enclosure makes it suitable for most indoor industrial settings.

Q: What is the process for adjusting the switching point or hysteresis?

A: The switching point within the 50-500 Pa range and hysteresis (typically 15 Pa) are adjustable, allowing you to fine-tune the pressure levels at which the switch activates or deactivates to best suit your specific monitoring or control requirements. Refer to the installation manual for step-by-step instructions.

Q: What are the main benefits of using the Sensocon 104 - 2 in OEM or standard applications?

A: Benefits include high reliability due to its SPDT contacts and flame-retardant ABS housing, fast response time (<1 second), ease of installation, and compliance with CE standards. These attributes ensure safe and efficient operation in a variety of industrial and commercial systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ADPS EDPS Differential Pressure Switch Wholesaler Category

Dwyer BDPA-08-2-N Adjustable Differential Pressure Switch

Dwyer BDPA-08-2-N Adjustable Differential Pressure Switch

Thread : NPT 1/4

Finishing : Other, Powder Coated

Accuracy : 2% of Full Scale

Outer Size : 125 mm (Approximate)

Seal Material : Nitrile Rubber

Scale Range : 0.08 to 0.8 Bar

Dwyer ADPS-06-2-N Adjustable Differential Pressure Switch

Dwyer ADPS-06-2-N Adjustable Differential Pressure Switch

Thread : Barbed Pressure Ports for 1/8 to 3/16 ID Tubing

Finishing : Other, Matte Body Finish

Accuracy : 15% of Full Scale

Outer Size : Overall Length 53 mm (2.09 in), Width 89 mm (3.5 in), Height 90 mm (3.54 in)

Seal Material : EPDM

Scale Range : 0.5 to 6 Inch Water Column (in w.c.)

Dwyer BDPA-03-2-N Adjustable Differential Pressure Switch

Dwyer BDPA-03-2-N Adjustable Differential Pressure Switch

Thread : 1/4 NPT Female

Finishing : Other, Powder Coated

Accuracy : 0.5% of F.S.

Outer Size : 108 x 98 x 58 mm (approx.)

Seal Material : Nitrile

Scale Range : 0.2 to 3.0 bar

Dwyer BDPA-07-2-N Adjustable Differential Pressure Switch

Dwyer BDPA-07-2-N Adjustable Differential Pressure Switch

Thread : G1/4 Female

Finishing : Other, Enamel coated metal, black finish

Accuracy : 2% F.S.

Outer Size : 66 mm x 121 mm x 94 mm (approx)

Seal Material : Nitrile rubber

Scale Range : 0.07 to 2 bar (1 to 30 psi)



Back to top