Nicotra Backward Curved Centrifugal Fan RDH 500 R
Nicotra Backward Curved Centrifugal Fan RDH 500 R

Nicotra Backward Curved Centrifugal Fan RDH 500 R

MOQ : 1 Piece

Nicotra Backward Curved Centrifugal Fan RDH 500 R Specification

  • Air Flow
  • 28000 m/h Max
  • Usage & Applications
  • Ventilation, Air Handling Units, Industrial Exhaust
  • Temperature
  • Up to 80C
  • Automation Grade
  • Automatic
  • Orientation
  • Horizontal
  • Power Source
  • Electric
  • Efficiency
  • High
  • Product Type
  • Backward Curved Centrifugal Fan
  • Material
  • Galvanized Steel
  • Cooling System
  • Air Cooled
  • Noise Level
  • 72 dB(A)
  • Capacity
  • 4400 - 28000 m/h
  • Voltage
  • 415 V
  • Weight
  • 160 kg
  • Dimension (L*W*H)
  • 870 mm x 680 mm x 860 mm
  • Surface
  • Powder Coated
 

Nicotra Backward Curved Centrifugal Fan RDH 500 R Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, North America, Western Europe, Middle East, Africa, Central America, South America, Asia, Eastern Europe
  • Main Domestic Market
  • All India
 

About Nicotra Backward Curved Centrifugal Fan RDH 500 R

Nicotra Backward Curved Centrifugal Fan RDH 500 R

Product Benefits 

 Product RDH 500 R 
Brand  Nicotra 
Description  Extractor Fan 
 Condition New  

  

Find Cheap Spare Parts For Machines Using The Products of Nicotra.Our Team of Experts Will Find the Best Sales Prices for products of Nicotra - RDH 500 R Extractor Fan in USA.Using the Products of Nicotra will Minimize Your Costs on Spare Parts.Our Job Is To Save You Time And Minimize your Expenses on spare Parts And Industrial Components.Our Company is Not an Official Distributor of Nicotra, but we are selling their Products at Competitive Prices.Purchase High quality spare parts of Nicotra - RDH 500 R Extractor fan in INDIA on Cheap Prices.With Each Day We Gain More and More Experience and That's Why We Are Able to Satisfy Your Needs For Spare Parts.You May Fill Out Our Request Form or Send Your Enquiry by E-Mail envirotech76@yahoo.co.in



Engineered for Industrial Ventilation

The RDH 500 R centrifugal fan excels in a wide range of industrial environments, including use in air handling units, industrial exhaust, and general ventilation. With a backward curved impeller and direct drive system, it ensures reliable operation, even under challenging conditions. Its base-mounted design allows for straightforward installation and stability, making it suitable for large-scale and continuous operation requirements.


Efficient Performance and Robust Construction

Crafted from powder-coated galvanized steel, the RDH 500 R withstands tough conditions while offering high efficiency. The direct drive 7.5 kW motor allows the fan to maintain high air flow rates and static pressures with minimal maintenance. An IP55 enclosure and air-cooled system safeguard the motor from dust and moisture, ensuring long-term reliability and optimal performance at temperatures up to 80C.

FAQs of Nicotra Backward Curved Centrifugal Fan RDH 500 R:


Q: How is the Nicotra RDH 500 R centrifugal fan installed and mounted?

A: The Nicotra RDH 500 R is base mounted, ensuring it can be securely fixed onto flat surfaces in various industrial environments. Its horizontal orientation and compact dimensions (870 mm x 680 mm x 860 mm) facilitate straightforward installation in air handling units or ventilation set-ups.

Q: What types of applications are suitable for the RDH 500 R centrifugal fan?

A: This model is ideal for ventilation, industrial exhaust, and air handling units, offering high air flow capacity and static pressure. Its robust construction and efficient motor make it perfect for demanding industrial or commercial uses requiring reliable, continuous airflow.

Q: When should the RDH 500 R be considered over other fan types?

A: Choose the RDH 500 R when you require high efficiency, substantial air volume movement (up to 28,000 m/h), and operation in environments with temperatures up to 80C. Its backward curved impeller also provides stable performance against varying system resistances.

Q: Where can the RDH 500 R be utilized for optimal results?

A: The fan can be effectively used in industrial plants, commercial ventilation systems, and air handling units where consistent, powerful airflow is necessary. Its powder-coated, IP55-rated motor allows operation in environments exposed to dust and moisture.

Q: What process does the direct drive mechanism follow in the RDH 500 R?

A: The direct drive feature connects the motor directly to the impeller, eliminating the need for belts or pulleys. This design reduces maintenance, enhances efficiency, and minimizes energy losses during operation.

Q: How does the backward curved impeller benefit system performance?

A: A backward curved impeller enhances efficiency, reduces risk of dust accumulation, and provides stable pressure across varying flow rates, resulting in long-lasting and reliable operation with lower noise levels.

Q: What are the main advantages of using the Nicotra RDH 500 R fan?

A: Primary benefits include high operational efficiency, robust build quality, reduced maintenance due to direct drive, reliable performance at elevated temperatures, and suitability for diverse industrial ventilation requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series RDH Nicotra Backard Curved Centrifugal Fan Category

Nicotra Backward Curved Centrifugal Fan RDH 355 R

Nicotra Backward Curved Centrifugal Fan RDH 355 R

Price 30000 INR

Minimum Order Quantity : 1 Piece

Product Type : Backward Curved Centrifugal Fan

Dimension (L*W*H) : 726 x 620 x 634 mm

Noise Level : < 80 dB(A)

Efficiency : High Efficiency Design

Nicotra Backward Curved Centrifugal Fan RDH 800 K

Nicotra Backward Curved Centrifugal Fan RDH 800 K

Price 140000 INR

Minimum Order Quantity : 1 Piece

Product Type : Backward Curved Centrifugal Fan

Dimension (L*W*H) : Approx. 1200 x 1300 x 900 mm

Noise Level : Less than 85 dB(A)

Efficiency : Up to 85%

Nicotra Backward Curved Centrifugal Fan RDH 225 R

Nicotra Backward Curved Centrifugal Fan RDH 225 R

Price 21800 INR

Minimum Order Quantity : 1 Piece

Product Type : Backward Curved Centrifugal Fan

Dimension (L*W*H) : 225 mm (Impeller Diameter)

Noise Level : 72 dB(A)

Efficiency : Up to 72%

Nicotra Backward Curved Centrifugal Fan RDH 900 K

Nicotra Backward Curved Centrifugal Fan RDH 900 K

Price 175000 INR

Minimum Order Quantity : 1 Piece

Product Type : Backward Curved Centrifugal Fan

Dimension (L*W*H) : 1400 x 1600 x 1650 mm (approx)

Noise Level : 86 dB(A)

Efficiency : High Efficiency



Back to top