Nicotra Backward Curved Centrifugal Fan RDH 900 K
Nicotra Backward Curved Centrifugal Fan RDH 900 K

Nicotra Backward Curved Centrifugal Fan RDH 900 K

MOQ : 1 Piece

Nicotra Backward Curved Centrifugal Fan RDH 900 K Specification

  • Orientation
  • Direct Drive
  • Usage & Applications
  • Industrial Ventilation, HVAC, Air Handling Units, Clean Rooms
  • Temperature
  • Up to 80C
  • Power Source
  • Electric
  • Air Flow
  • 12000 - 83000 m/h
  • Efficiency
  • High Efficiency
  • Automation Grade
  • Manual / Optional Automation
  • Product Type
  • Backward Curved Centrifugal Fan
  • Material
  • Steel/Aluminium
  • Cooling System
  • Air Cooled
  • Noise Level
  • 86 dB(A)
  • Capacity
  • 12000 - 83000 m/h
  • Voltage
  • 400 V
  • Weight
  • 485 kg (approx)
  • Dimension (L*W*H)
  • 1400 x 1600 x 1650 mm (approx)
  • Surface
  • Powder Coated / Painted
 

Nicotra Backward Curved Centrifugal Fan RDH 900 K Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Paypal, Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Eastern Europe, Africa, Central America, Middle East, South America, Western Europe, Asia, North America, Australia
  • Main Domestic Market
  • All India
 

About Nicotra Backward Curved Centrifugal Fan RDH 900 K

Nicotra Backward Curved Centrifugal Fan RDH 900 K

Product Benefits 

 Product RDH 900 K 
Brand  Nicotra 
Description  Extractor Fan 
 Condition New  

  

Find Cheap Spare Parts For Machines Using The Products of Nicotra.Our Team of Experts Will Find the Best Sales Prices For Products of Nicotra - RDH 900 K Extractor Fan in USA.Using the Products of Nicotra Will Minimize Your Costs On Spare Parts.Our Job Is To Save You Time And Minimize Your Expenses On Spare Parts And Industrial Components.Our Company Is Not An Official Distributor of Nicotra, But We Are Selling Their Products At Competitive Prices.Purchase High Quality Spare Parts of Nicotra - RDH 900 K Extractor fan in INDIA on Cheap Prices.With Each Day We Gain More and More Experience and Thats Why We Are Able to Satisfy Your Needs For Spare Parts.You May Fill Out Our Request Form or Send Your Enquiry by E-Mail envirotech76@yahoo.co.in



Robust Construction for Demanding Applications

The RDH 900 K features a welded steel/aluminium housing, powder-coated or painted to resist corrosion and wear. This construction ensures high durability and minimal maintenance, making it an ideal choice for industrial installations, HVAC, and clean room environments requiring dependable airflow.


High Performance and Efficiency

With a capacity ranging from 12,000 to 83,000 m/h and static pressures up to 1000 Pa, this centrifugal fan delivers high efficiency and reliable air movement. Operating at noise levels of 86 dB(A), the fan is engineered for powerful performance while maintaining energy efficiency and environmental comfort.


Flexible Mounting and Drive Options

The Nicotra RDH 900 K comes with versatile foot mounting for stable installation and offers both direct and belt drive configurations. This flexibility allows integration into new or existing systems with ease, ensuring the fan can meet diverse application requirements across facilities.

FAQs of Nicotra Backward Curved Centrifugal Fan RDH 900 K:


Q: How is the Nicotra RDH 900 K Centrifugal Fan typically installed?

A: The RDH 900 K is designed for foot mounting, offering stable and secure installation in industrial and HVAC setups. Its robust construction accommodates varying layouts and makes integration with existing air handling units straightforward.

Q: What are the main benefits of using a backward curved impeller in this fan?

A: The backward curved impeller enhances efficiency and reduces energy consumption while minimizing risk of overloading. This design ensures stable airflow and reliably handles high static pressures up to 1000 Pa, ideal for industrial ventilation and clean room applications.

Q: When should I opt for direct drive versus belt drive configurations?

A: Direct drive is recommended for lower maintenance and higher energy efficiency, while belt drive offers flexibility in speed adjustments to match unique airflow requirements. The choice depends on your specific application and control needs.

Q: Where is the fan motor positioned and how does it affect performance?

A: The motor is placed outside the airflow, which prevents contamination and overheating. This layout extends motor lifespan and ensures the delivery of clean, dependable ventilationespecially important in sensitive environments like clean rooms.

Q: What processes ensure the durability and reliability of the Nicotra RDH 900 K?

A: The fan is constructed with welded steel or aluminium, powder coated or painted to resist corrosion. It uses sealed ball bearings and an air-cooled motor with IP55 protection to secure consistent performance and longevity, even in challenging environments.

Q: How can the fans operation be controlled and automated?

A: The Nicotra RDH 900 K offers manual operation by default, with optional automation available. This allows integration with building management systems or custom controls to optimize airflow and efficiency as per the users requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series RDH Nicotra Backard Curved Centrifugal Fan Category

Nicotra Backward Curved Centrifugal Fan RDH 560 R

Nicotra Backward Curved Centrifugal Fan RDH 560 R

Price 60000 INR

Minimum Order Quantity : 1 Piece

Automation Grade : Standard / Manual

Noise Level : <85 dB(A)

Dimension (L*W*H) : 890 mm x 890 mm x 860 mm (approx.)

Product Type : Backward Curved Centrifugal Fan

Nicotra Backward Curved Centrifugal Fan RDH 710 R

Nicotra Backward Curved Centrifugal Fan RDH 710 R

Price 98600 INR

Minimum Order Quantity : 1 Piece

Automation Grade : SemiAutomatic

Noise Level : 85 dB (A) at 1m

Dimension (L*W*H) : 1150 mm x 1850 mm x 1420 mm

Product Type : Backward Curved Centrifugal Fan

Nicotra Backward Curved Centrifugal Fan RDH 710 K

Nicotra Backward Curved Centrifugal Fan RDH 710 K

Price 120000 INR

Minimum Order Quantity : 1 Piece

Automation Grade : Semi Automatic

Noise Level : 75 dB(A)

Dimension (L*W*H) : 1100 x 1100 x 900 mm

Product Type : Backward Curved Centrifugal Fan

Nicotra Backward Curved Centrifugal Fan RDH 180 R

Nicotra Backward Curved Centrifugal Fan RDH 180 R

Price 17900 INR

Minimum Order Quantity : 1 Piece

Automation Grade : Manual

Noise Level : 65 dB(A)

Dimension (L*W*H) : 380 x 285 x 340 mm

Product Type : Backward Curved Centrifugal Fan