Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC
Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC

Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC

MOQ : 12 Pieces

Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC Specification

  • Seal Material
  • Silicone or Buna-N (depending on model specification)
  • Display
  • Analog
  • Grade
  • Industrial
  • Thread
  • No threaded connection (uses rear or surface mounting)
  • Sensor Type
  • Capsule Element
  • Outer Size
  • About 168 mm diameter (6-5/8 inches)
  • Material
  • Die-cast aluminum case, acrylic cover
  • Dial Material
  • White aluminum dial with printed scale
  • Pointer Material
  • Red tipped aluminum pointer
  • Processing Type
  • Pressure sensing, mechanical
  • Diameter
  • 168 mm (6-5/8 inches)
  • Glass Size
  • Clear acrylic cover, full gauge diameter
  • Mount Type
  • Surface or flush mount
  • Scale Range
  • 0-100 Inch W.C. (Water Column)
  • Accuracy
  • 2% of full scale
  • Finishing
  • Black anodized die-cast aluminum housing
  • Measure Pressure Of
  • Low air & non-corrosive gas pressures
  • Accessories
  • Two 1/8 NPT plugs, four flush mounting adapters, and two 1/8 rubber tubing adapters
 

Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC Trade Information

  • Minimum Order Quantity
  • 12 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cheque, Cash Against Delivery (CAD), Cash in Advance (CID)
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC

Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC

Dwyer 2100 Differential pressure gage, range 0-100" w.c. (inches of water), minor divisions 2.0.

Using Dwyer's simple, frictionless Magnehelic Gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.

The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Features

Bezel provides flange for flush mounting in panel.

Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Precision litho-printed scale is accurate and easy to read.

Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

Pointer stops of molded rubber prevent pointer over-travel without damage.

"Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.

O-ring seal for cover assures pressure integrity of case.



Reliable Differential Pressure Measurement

Engineered specifically for low-pressure air and non-corrosive gas monitoring, this gage ensures precise readings in industrial settings. Its capsule element sensor provides consistent accuracy even in demanding conditions, while the 0-100 Inch WC range covers most HVAC, filtration, and cleanroom applications.


Durable and Versatile Construction

Constructed with a die-cast aluminum case and a clear acrylic window, the Model 2100 Magnehelic offers resilience in industrial environments. Flexible mounting options and included adapters ensure compatibility with various installation requirements, making it suitable for surface or flush mounting.


User-Friendly Calibration and Maintenance

Featuring an external zero adjustment screw, the Magnehelic Gage allows for quick and easy recalibrationno disassembly required. The analog display with a white aluminum dial and red-tipped pointer enhances readability, supporting efficient operation and maintenance routines.

FAQs of Dwyer USA Model 2100 Magnehelic Gage Range 0-100 Inch WC:


Q: How do I install the Dwyer Model 2100 Magnehelic Gage?

A: The gage can be mounted vertically using the included flush adapters or surface mounting kits. Connections are provided at both the side and rear, and setup requires attaching the appropriate 1/8 NPT or rubber tubing adapters for your application. Ensure the mounting orientation remains vertical for optimal accuracy.

Q: What types of media can this pressure gage measure?

A: This model is intended for air and non-corrosive gas differential pressure applications. It should not be used with liquids, aggressive gases, or corrosive substances to avoid damage to the internal components and seals.

Q: When should I recalibrate the Magnehelic Gage?

A: Regular recalibration is recommended according to your facilitys maintenance schedule or after any mechanical shock or overpressure event. The external zero adjustment screw makes it simple to recalibrate without removing the gage from its installation.

Q: Where should this gauge be used for best results?

A: Ideal locations include HVAC system monitoring, cleanroom pressure measurement, air filter status, and other industrial environments requiring reliable low-pressure measurement. For accurate operation, install it in a vertical orientation and protect from temperature extremes.

Q: What are the core benefits of using this gauge?

A: Benefits include high accuracy (2% full scale), robust industrial design, ease of installation, and straightforward recalibration. The analog display enables quick visual checks, aiding in proactive maintenance and process control.

Q: How does the gage handle overpressure situations?

A: The Model 2100 can safely tolerate overpressures up to 15 psi (1.03 bar). Exceeding this limit may compromise gage accuracy or damage the sensor; always operate within specified ranges for maximum device longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Differential Pressure Gauge Category

Dwyer USA Model 2008 Magnehelic Gage Range 0-8.0 Inch WC

Dwyer USA Model 2008 Magnehelic Gage Range 0-8.0 Inch WC

Minimum Order Quantity : 12 Paints

Diameter : About 4 inches

Grade : Industrial Grade

Display : Analog Dial

Finishing : Other, Black Diecast Aluminum Case with Acrylic Cover

Seal Material : Silicone Rubber

Front Mount Differential Pressure Gauge

Front Mount Differential Pressure Gauge

Diameter : 100mm

Grade : Industrial

Display : Analog

Finishing : Other, Powder Coated

Seal Material : Neoprene

Dwyer 2000-150CM Magnehelic Differential Pressure Gauge

Dwyer 2000-150CM Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 12 Pieces

Diameter : 4 (100 mm)

Grade : Industrial Grade

Display : Analogue

Finishing : Other, Powder Coated/Anodized

Seal Material : Silicone (optional BunaN)

Dwyer USA Magnehelic Gauges 0 To 15 MM WC

Dwyer USA Magnehelic Gauges 0 To 15 MM WC

Diameter : 4 Inch (Approx. 100 mm)

Grade : Industrial Grade

Display : Analog Dial

Finishing : Other, Matte Black Case Finish

Seal Material : Silicone Rubber



Back to top