Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM
Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM

Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM

Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM Specification

  • Outer Size
  • 178 mm x 178 mm (approx.)
  • Seal Material
  • Neoprene
  • Display
  • Analog
  • Sensor Type
  • Photohelic Switch/Gauge
  • Thread
  • Panel Mount Thread
  • Grade
  • Industrial
  • Material
  • Die-cast Aluminum
  • Dial Material
  • Polycarbonate
  • Pointer Material
  • Aluminum
  • Processing Type
  • Precision Calibrated
  • Diameter
  • 178 mm (Face Diameter)
  • Glass Size
  • 124 mm (Viewing Area Diameter)
  • Mount Type
  • Flush Panel Mount
  • Scale Range
  • 0 to 100 mm
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Matte Black Housing
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Mounting Screws, Instruction Manual
 

Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cheque, Cash Against Delivery (CAD), Cash in Advance (CID), Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, Africa, South America, Western Europe, Asia, Central America
  • Main Domestic Market
  • All India
 

About Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM

Dwyer 3000MR Photohelic,Switch/Gauge 0 to 100 MM

 

Series 3000MR/3000MRS Photohelic® Switch/Gage

Combines Differential Pressure Gage with Low/High Set-Points, Compact Size

 

 ModelDescription 
 3000MR-100MMPressure Switch/Gage,Range 0-100MM, 2.0 minor divisions.
 

 

Includes

  • mounting ring, snap ring
  • 18" cable assembly
  • (2) 3/16" tubing to 1/8" NPT adapters
  • (2) 1/8" NPT pipe plugs
  • (4) 6-32 x 1-1/4" RH machine screws (panel mounting)
  • (3) 6-32 x 5/16" RH machine screws (surface mounting)

he Series 3000MR Photohelic® Switch/Gage combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic® gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.

Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig.

Applications

  • Fan Control
  • Damper Control
  • Environmental Pollution Control

Approvals

  • CE Approval
  • GOST-R Certificate

Specification

Service Air and non-combustible, compatible gases 
Accuracy ±2% of FS at 70°F 
Pressure Limits -20" Hg to 25 psig 
Temperature Limits 20 to 120°F 
Process Connections 1/8 female NPT (duplicated side and back) 
Size 4" dial face, 5" O.D. x 3-1/8" 
 Weight1.8 lb 
 Switch Specifications 
 Switch TypeEach setpoint has 1 Form C relay (SPDT) 
 Relay Contacts(resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits 
 Electrical Connections18" cable assembly with 8 conductors 
 Power Requirements24 VDC, regulated ±10% 
 Mounting OrientationDiaphragm in vertical position 
Set Point Adjustment Adjustable knobs on face 
 Agency ApprovalsCE 



Seamless Pressure Control and Monitoring

The Dwyer 3000MR Photohelic Switch/Gauge ensures accurate air and non-corrosive gas pressure monitoring for industrial settings. Its analog display and precision calibration lend confidence to critical processes requiring both monitoring and integrated switching capabilities. Dual SPDT relays with instantaneous response allow for seamless automation, reducing manual oversight and enhancing safety in operations.


Built for Industrial Performance

Housed in a matte-finished, die-cast aluminum enclosure rated NEMA 4X (IP66), this gauge stands up to harsh environments while maintaining accuracy. The flush panel mount and front-accessible adjustment knobs streamline installations and set point changes. Suitable for continuous operation in temperatures ranging from -18C to 60C, its favored across manufacturing and industrial sectors nationwide.

FAQs of Dwyer 3000MR Photohelic Switch/Gauge 0 to 100 MM:


Q: How do I install the Dwyer 3000MR Photohelic Switch/Gauge?

A: The 3000MR is installed using the included mounting screws, fitting into a panel mount thread with a flush panel mount. Electrical wiring is made via screw terminals, and installation must be completed following the instructions in the manual for safe and accurate setup.

Q: What type of measurements can the Dwyer 3000MR handle?

A: This model measures differential pressure of air and non-corrosive gases within a range of 0 to 100 mm. Its analog dial ensures clearly readable values for effective process monitoring.

Q: When should I use the set point adjustment knobs?

A: Set point adjustment knobs are used when setting or modifying the pressure values at which the dual SPDT relay switches activate. These adjustments can be made anytime from the front-accessible panel without disassembly, allowing for quick changes during commissioning or routine process modifications.

Q: Where can the Dwyer 3000MR be deployed?

A: The enclosures IP66 (NEMA 4X) rating allows the 3000MR to be installed in demanding indoor or outdoor industrial locations. Its robust build makes it suitable for manufacturing, handling plants, HVAC, and similar applications in India.

Q: What is the process to calibrate or maintain accuracy on this gauge?

A: The 3000MR comes precision calibrated. For continued accuracy (2% of full scale), regular inspection and calibration checks should be performed as per the manufacturers guidelines, especially after heavy wear or process changes.

Q: How does the dual SPDT relay switching benefit my application?

A: Dual SPDT relay switches provide automated control functions, such as triggering alarms or operating external devices based on pressure thresholds, thus reducing manual monitoring and increasing reliability and safety in your system.

Q: What are the key benefits of choosing the Dwyer 3000MR Photohelic Switch/Gauge?

A: The main advantages include real-time visual monitoring, seamless automation through instantaneous switching, robust industrial construction, easy front-panel adjustments, and compliance with RoHS and CE standards, ensuring safe and environmentally conscious operation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer Series 3000MR/3000MRS Photohelic Switch-Gage Category

Series 3000MR/3000MRS Photohelic Switch/Gage

Series 3000MR/3000MRS Photohelic Switch/Gage

Outer Size : 4 (101.6 mm) Diameter Front Bezel

Measure Pressure Of : Other, Air and Compatible Gases

Seal Material : Silicone Rubber

Accessories : Mounting Bracket, Instruction Manual, Terminal Screws

Diameter : 101.6 mm (4 inches)

Display : Analog with Dual Set Point Indicators

Dwyer 3015MRS Photohelic Switch/Gauge 0 to 15 inch

Dwyer 3015MRS Photohelic Switch/Gauge 0 to 15 inch

Outer Size : 49/16 inch (115.9 mm) Diameter

Measure Pressure Of : Other, Low Air and NonCorrosive Gas

Seal Material : Silicone

Accessories : Mounting Hardware, Instruction Manual

Diameter : 49/16 inch (115.9 mm)

Display : Analog with Digital Switching

Dwyer 3000MR Photohelic Switch/Gauge 0 to 50 MM

Dwyer 3000MR Photohelic Switch/Gauge 0 to 50 MM

Outer Size : Standard 4 (101 mm) Diameter

Measure Pressure Of : Other, Low Air or NonCorrosive Gases

Seal Material : Neoprene (Standard)

Accessories : Mounting ring, snap ring, and screws included

Diameter : 4 inches (101 mm)

Display : Analog Dial

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Outer Size : 41/2 inches (115 mm) dia. case

Measure Pressure Of : Other, Air and Noncorrosive Gases

Seal Material : Silicone Rubber

Accessories : Mounting Bracket, Screws, Electrical Connectors

Diameter : 115 mm (41/2 in)

Display : Analog & Dual Switches



Back to top