Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa
Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa Specification

  • Thread
  • 1/8 NPT Female
  • Sensor Type
  • Differential Pressure
  • Outer Size
  • 110 mm Approx
  • Grade
  • Industrial
  • Bourdon Tube
  • Not Present
  • Seal Material
  • Silicone
  • Display
  • Analog and Setpoint Switch
  • Material
  • Die-Cast Aluminum Case, Acrylic Lens
  • Dial Material
  • Acrylic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Molded
  • Diameter
  • Approximately 4-1/2 (114 mm)
  • Glass Size
  • 110 mm diameter
  • Mount Type
  • Flush & Surface Mount
  • Scale Range
  • 0 to 500 Pa
  • Accuracy
  • 2% of full scale
  • Finishing
  • Matte Finish
  • Measure Pressure Of
  • Air and non-combustible gases
  • Accessories
  • Mounting Hardware & Instruction Manual
 

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Eastern Europe, Middle East, Western Europe, Africa, South America, Asia, Central America, North America, Australia
  • Main Domestic Market
  • All India
 

About Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa

Series 3000MR/3000MRS Photohelic® Switch/Gage

Combines Differential Pressure Gage with Low/High Set-Points,Compact Size

 

 ModelDescription 
 3000MRS-500 PaPressure Switch/Gage,Range 0-500 Pa, 10.0 minor divisions.
 

 

Includes

  • mounting ring, snap ring
  • 18" cable assembly
  • (2) 3/16" tubing to 1/8" NPT adapters
  • (2) 1/8" NPT pipe plugs
  • (4) 6-32 x 1-1/4" RH machine screws (panel mounting)
  • (3) 6-32 x 5/16" RH machine screws (surface mounting)

he Series 3000MR Photohelic® Switch/Gage combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic® gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.

Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig.

Applications

  • Fan Control
  • Damper Control
  • Environmental Pollution Control

Approvals

  • CE Approval
  • GOST-R Certificate

Specification

Service Air and non-combustible, compatible gases 
Accuracy ±2% of FS at 70°F 
Pressure Limits -20" Hg to 25 psig 
Temperature Limits 20 to 120°F 
Process Connections 1/8 female NPT (duplicated side and back) 
Size 4" dial face, 5" O.D. x 3-1/8" 
 Weight1.8 lb 
 Switch Specifications 
 Switch TypeEach setpoint has 1 Form C relay (SPDT) 
 Relay Contacts(resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits 
 Electrical Connections18" cable assembly with 8 conductors 
 Power Requirements24 VDC, regulated ±10% 
 Mounting OrientationDiaphragm in vertical position 
Set Point Adjustment Adjustable knobs on face 
 Agency ApprovalsCE 

  



Exceptional Measurement Range and Accuracy

The Dwyer 3000MRS Photohelic Switch/Gauge covers differential pressures from 0 to 500 Pa with a fine resolution of 3 Pa graduations. Thanks to its 2% full-scale accuracy and 1% repeatability, it ensures reliable and consistent monitoring critical for demanding industrial applications.


User-Friendly Installation and Adjustable Setpoints

Mounting options include both flush and surface configurations, catering to diverse installation needs. The front-accessible setpoint adjustment makes on-site calibration straightforward. Accessories like mounting hardware and a detailed manual further simplify setup and daily operation.


Rugged Construction for Industrial Environments

Constructed from die-cast aluminum with a matte finish and an acrylic lens, the 3000MRS withstands harsh industrial conditions. Its IP52 (NEMA 2) enclosure ensures adequate dust and moisture protection, making it suitable for routine operations in a range of manufacturing facilities.

FAQs of Dwyer 3000MRS Photohelic Switch/Gauge 0 to 500 Pa:


Q: How do I install the Dwyer 3000MRS Photohelic Switch/Gauge?

A: The Dwyer 3000MRS can be mounted using the included hardware for either flush or surface installation. Refer to the provided instruction manual for step-by-step guidance on securing the die-cast aluminum case and connecting the 1/8 NPT female ports.

Q: What is the main benefit of using the 3000MRS model in industrial settings?

A: This gauge offers versatile differential pressure monitoring and control with an analog display and setpoint switch, supporting immediate relay output. Its robust accuracy, repeatability, and durable housing make it reliable for industrial air and non-combustible gas applications.

Q: When should the setpoint switches be adjusted, and how is this achieved?

A: Setpoint adjustments are typically performed during initial installation or whenever process parameters change. The switches can be accessed from the gauges front panel, allowing quick and precise adjustment without needing to dismantle the device.

Q: Where can the 3000MRS be deployed effectively?

A: The Dwyer 3000MRS is suitable for use in factories, clean rooms, HVAC systems, or any environment requiring differential pressure measurement of air or non-combustible gases. Its IP52 rating and operating temperature range make it adaptable to various industrial locations.

Q: What type of power supply does the gauge require?

A: Depending on configuration, the Dwyer 3000MRS operates with either 120 VAC or 240 VAC power sources, with a relay output rated at 5A for use with standard industrial electrical systems.

Q: How should I maintain and clean the 3000MRS Photohelic Gauge?

A: Maintain the device by keeping it free from dust and ensuring connection ports remain unclogged. Clean the acrylic lens with a soft cloth. Avoid harsh cleaners that could damage the matte finish or acrylic components.

Q: Can the Dwyer 3000MRS measure combustible or hazardous gases?

A: No, the 3000MRS is specifically designed for air and non-combustible gases only. Using it with other media may compromise safety and measurement accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer Series 3000MR/3000MRS Photohelic Switch-Gage Category

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 25 MM

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 25 MM

Sensor Type : Differential Pressure Sensor

Thread : 1/8 NPT Female

Finishing : Other, Textured Black Enamel Case

Material : Other, DieCast Aluminum Case, Polycarbonate Front Cover

Outer Size : (Approx.) 115 mm Diameter

Dial Material : Other, White Aluminum

Dwyer 3000MR-0 Photohelic Differential Pressure Switch/Gauge RANGE 0-0.5

Dwyer 3000MR-0 Photohelic Differential Pressure Switch/Gauge RANGE 0-0.5"w.c.

Sensor Type : Differential Pressure Sensor

Thread : 1/8 NPT Female

Finishing : Other, Black Textured Case Finish

Material : Other, DieCast Aluminum Case, Polycarbonate Cover

Outer Size : 4 inches (101.6 mm) diameter

Dial Material : Other, White Aluminum

Dwyer 3000MR Photohelic Switch/Gauge 0 to 6 MM

Dwyer 3000MR Photohelic Switch/Gauge 0 to 6 MM

Sensor Type : Photohelic Differential Pressure Sensor

Thread : 1/8 NPT Female Connections

Finishing : Other, Powder Coated/Anodized Housing

Material : Other, Diecast Aluminium Case, Acrylic Cover

Outer Size : 152 mm (Front Flange Diameter)

Dial Material : Other, Acrylic

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 250 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 250 Pa

Sensor Type : Differential Pressure Switch/Gauge

Thread : 1/8 NPT Female

Finishing : Other, Powder coated housing

Material : Other, Diecast aluminum housing, Acrylic cover

Outer Size : Approximately 4.75 in (121 mm) diameter

Dial Material : Other, Acrylic



Back to top