Sensocon USA 212-D005P-3 Differential Pressure Transmitter
Sensocon USA 212-D005P-3 Differential Pressure Transmitter

Sensocon USA 212-D005P-3 Differential Pressure Transmitter

Sensocon USA 212-D005P-3 Differential Pressure Transmitter Specification

  • Sensor Type
  • Differential Pressure Sensor
  • Outer Size
  • 117 mm x 78 mm x 49 mm (approx)
  • Grade
  • Industrial
  • Display
  • Digital
  • Seal Material
  • Integral Gasket (Material: Nitrile or Equivalent)
  • Thread
  • 1/8 NPT Female
  • Material
  • ABS Plastic Housing, Electronic Internal Components
  • Processing Type
  • Electronic
  • Mount Type
  • Panel / Wall Mount
  • Scale Range
  • 0 - 5.00 in. w.c. (inches water column)
  • Accuracy
  • 1% of F.S.
  • Finishing
  • Textured Plastic Housing
  • Measure Pressure Of
  • Air and Compatible Gases
  • Accessories
  • Mounting Kit, Instruction Manual
  • Viewing Angle
  • 178
  • Smart TV Features
  • Built-in WiFi, Screen Mirroring
  • Sleep Timer
  • Yes
  • USB Ports
  • 2
  • Operating System
  • Android
  • Remote Battery Type
  • AAA
  • Refresh Rate
  • 60 Hz
 

Sensocon USA 212-D005P-3 Differential Pressure Transmitter Trade Information

  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Main Export Market(s)
  • Australia, North America, South America, Eastern Europe, Middle East, Western Europe, Africa, Central America, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA 212-D005P-3 Differential Pressure Transmitter

Sensocon USA 212-D005P-3 Differential Pressure Transmitter

The Series 212 Weatherproof Differential Pressure Transmitter can accurately measure positive, negative, or differential pressure and send a corresponding 4-20 mA or 0-10 V output signal. The Series 212 Weatherproof Differential Pressure Transmitter is designed with an IP 65 enclosure and can be easily mounted to any flat surface. The Series 212 is not position sensitive and can be mounted in any orientation without compromising accuracy. The compact, lightweight design makes installation simple and easy.

SPECIFICATIONS
  • Maximum Pressure:    Ranges 5 PSI (35 kPa) = 15 PSI (100kPa) MaxRanges > 5 PSI (35 kPa) = 30 PSI (200kPa) Max
  • Media compatibility:    Air and compatible non-combustible, non-corrosive gases
  • Accuracy:    Ranges 4" w.c. (1kPa) 1.0%Ranges 5" w.c. (1.25kPa) 0.25%
  • Temperature Ranges:    Compensated: 15 to 120F (-10 to 50C)Operating: -10 to 155F (-25 to 70C)
  • Thermal Effect:    +/- 0.028% FS/F (+/- 0.50% FS/C)
  • Stability:    +/- 0.25% FS/year
  • Output Signal:    4-20 mA, 2-wire or 0 - 10 V
  • Loop Resistance:    250 @ 24 VDC
  • Power Supply:    12-30 VDC
  • Enclosure Rating:    IP 65
  • Electrical Connections:    screw terminals
  • Electrical Entry:    PG7 Cable Gland
  • Process Connection:   Barbed fittings for 3/16 flexible tubing
  • Agency Approvals:CE      



High Accuracy Differential Pressure Measurement

With a 05.00 in. w.c. measurement range and 1% of F.S. accuracy, the 212-D005P-3 guarantees precise pressure readings for air and compatible gases. Its electronic processing and rapid 5 ms response time make it ideal for dynamic applications needing real-time monitoring.


Built for Durable Industrial Use

Encased in a textured ABS plastic housing with IP65 ingress protection, the transmitter resists dust and splashes, offering dependable operation in diverse industrial settings. Its integral nitrile gasket ensures a secure seal, making it suitable for demanding environments.


Easy Installation and Configuration

Featuring screw terminal electrical connections and an included mounting kit, the device is straightforward to install on panels or walls. Push-button onboard zero and span adjustments simplify calibration, while the digital display offers instant, direct readings.

FAQs of Sensocon USA 212-D005P-3 Differential Pressure Transmitter:


Q: How do I install the Sensocon 212-D005P-3 Differential Pressure Transmitter?

A: Installation is straightforward: use the supplied mounting kit to secure the transmitter onto a panel or wall. Connect electrical wiring through the screw terminals and attach tubing to the 1/8 NPT female pressure ports. Refer to the included instruction manual for detailed, step-by-step guidance.

Q: What media can be measured using this transmitter?

A: The Sensocon 212-D005P-3 is designed to measure clean, dry air or other non-corrosive gases. It is not suitable for liquids or corrosive/contaminated gases, as these could damage the internal components and affect the devices performance.

Q: When should I use the zero and span adjustment buttons?

A: Use the onboard push-button zero and span adjustments during installation or maintenance to calibrate the transmitter. Zero adjustment is recommended if the device is exposed to changing environmental conditions, while span adjustment is used to fine-tune the measurement range.

Q: Where is the best location to mount the 212-D005P-3 transmitter?

A: For optimal accuracy, mount the device in a stable area free from direct sun, excessive vibration, or moisture. Secure placement on a vertical surface near the measurement point and away from any mechanical obstructions is ideal.

Q: What is the benefit of the 4-20 mA (2-wire) output signal?

A: The 4-20 mA output provides a robust, industry-standard analog signal for easy integration into data acquisition systems, PLCs, and building management controls. It is highly resistant to electrical noise and signal losses over long cable runs, ensuring reliable data transmission.

Q: How does the IP65 rating enhance the transmitters durability?

A: The IP65 rating ensures that the device is dust-tight and protected against low-pressure water jets from any direction. This makes it suitable for harsh industrial environments, maintaining performance even with occasional exposure to dust or splashed water.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in 212 Weather Proof Differential Pressur Transmitter Category

Series 212 Weather-Proof Differential Pressure Transmitter

Series 212 Weather-Proof Differential Pressure Transmitter

Processing Type : Other, WeatherProof, Sealed, Factory Calibrated

Scale Range : 01000 Pa, 05000 Pa, 010000 Pa (Different Models)

Mount Type : Other, Wall or Panel Mount

Grade : Industrial

Measure Pressure Of : Other, Air and NonCorrosive Gases

Outer Size : WeatherProof Enclosure, IP65

Sensocon USA  212-D015P-3 Differential Pressure Transmitter

Sensocon USA 212-D015P-3 Differential Pressure Transmitter

Processing Type : Other, Electronic

Scale Range : 015 in. w.c. (inches of water column)

Mount Type : Other, Wall mount

Grade : Industrial

Measure Pressure Of : Other, Air and noncorrosive gases

Outer Size : 4.5 x 2.5 x 1.2 inches

Sensocon USA 212-D005K-3 Differential Pressure Transmitter

Sensocon USA 212-D005K-3 Differential Pressure Transmitter

Processing Type : Other, Electronic

Scale Range : 05 kPa (05000 Pa)

Mount Type : Other, Wall Mount

Grade : Industrial

Measure Pressure Of : Other, Air and NonCorrosive Gases

Outer Size : 4.72 x 4.72 x 2.17 inches (120 x 120 x 55 mm)

Sensocon USA 212-D010P-3 Differential Pressure Transmitter

Sensocon USA 212-D010P-3 Differential Pressure Transmitter

Processing Type : Other, Electronic

Scale Range : 010 inch WC

Mount Type : Other, Wall & Panel Mount

Grade : Industrial

Measure Pressure Of : Other, Air and Noncorrosive Gases

Outer Size : 110mm x 80mm x 37mm



Back to top