About SENSOCON Differential Pressure Gauge In Kanal Industrial Estate Mumbai

SENSOCON Differential Pressure Gauge In Kanal Industrial Estate Mumbai
Series S2000 SENSOCON Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed,Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,With acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
SENSOCON By Model Number Popularity
- FILTER BY
- Range - Pascals
| Model |
Description |
| S2000-100PA |
Differential Pressure Gage,Range 0-100 Pa,Minor Divisions 2.0,Calibrated For Vertical Scale Position. |
| S2000-125PA |
Differential Pressure Gage,Range 0-125 Pa,Minor Divisions 5.0,Calibrated For Vertical Scale Position. |
| S2000-250PA |
Differential Pressure Gage,Range 0-250 Pa,Minor Divisions 5.0. |
| S2000-300PA |
Differential Pressure Gage,Range 0-300 Pa,Minor Divisions 10.0. |
| S2000-30PA |
Differential Pressure Gage,Range 0-30 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
| S2000-500PA |
Differential Pressure Gage,Range 0-500 Pa,Minor Divisions 10.0. |
| S2000-60PA |
Differential Pressure Gage,Range 0-60 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
| S2000-750PA |
Differential Pressure Gage,Range 0-750 Pa,Minor Divisions 25.0. |
Additional Information:

Precision Pressure Measurement
Designed for rigorous industrial environments, the SENSOCON Differential Pressure Gauge offers exceptional mechanical durability and reliable accuracy. Its broad compatibility with gases and multiple measurement units make it a versatile choice for monitoring and controlling pressure differentials in crucial processes. The gauge's analog display delivers instant, clear readings to ensure operational safety and efficiency.
Versatile Industrial Applications
Suitable for sectors including pharmaceuticals, power generation, cement manufacturing, steel processing, fertilizers, and textiles, this gauge is a vital tool for maintaining optimal process conditions. Its adaptable scale range and robust construction support seamless integration into both new and existing monitoring systems within these demanding industries.
User-Friendly Mounting and Maintenance
Installation is straightforward with back and side 1/8" NPT connections, making the SENSOCON gauge suitable for both panel and surface mounting. Weighing just 550 grams, it is easy to handle. Routine cleaning of the dial and proper calibration ensure lasting performance and minimal service interruptions, supporting continuous plant operation.
FAQ's of SENSOCON Differential Pressure Gauge In Kanal Industrial Estate Mumbai:
Q: How do I install the SENSOCON Differential Pressure Gauge in my industrial setup?
A: Installation is accomplished using the provided 1/8" female NPT pressure taps, available on both back and side pairs. This flexible mounting design enables convenient placement in panels or direct surface mountings according to your system requirements.
Q: What types of industries can benefit the most from using this pressure gauge?
A: This gauge is particularly beneficial for pharmaceutical, power generation, cement, steel, fertilizer, and textile industries. It's engineered to monitor gas pressure differentials, helping ensure process safety and efficiency in these environments.
Q: When is recalibration or maintenance of the gauge necessary?
A: Regular calibration is recommended, typically every 6 to 12 months depending on operational conditions. If you notice significant deviations in readings or after exposure to harsh environments, a recalibration may be needed to sustain measurement accuracy.
Q: Where should the SENSOCON Differential Pressure Gauge be mounted for best results?
A: To achieve optimal readings, mount the gauge as close as possible to the point of measurement, using either back or side NPT connections. Ensure it is installed in a location with minimal vibration and direct exposure to process gases.
Q: What benefits does the 4-inch diameter analog display offer?
A: The large 4-inch dial face provides clear, easy-to-read measurements, reducing the chances of misinterpretation. Its analog nature allows for immediate visual assessment, making it ideal for quick field checks and continuous monitoring.
Q: How accurate is the gauge across different pressure ranges?
A: The gauge delivers an accuracy of 2% of full scale for most ranges, with slightly reduced accuracy (up to 4%) at very low-pressure applications (-00, -60PA, -6MM), all measured at 70F (21.1C). This ensures reliable data throughout its operational spectrum.