PVC Virgin Drift Eliminator Specification

  • Application
  • Cooling Tower
  • Material
  • PVC
  • Condition
  • New
  • Type
  • Drift Eliminator
  • Dimension (L*W*H)
  • 600 MM X 600 MM X 125 MM Millimeter (mm)
  • Cooling Type
  • Evaporative (Accessory)
  • Noise Control
  • Reduces Water Drift & Associated Noise
  • Refresh Rate
  • 60 Hz
  • Operating System
  • Android
  • Remote Battery Type
  • AAA
  • USB Ports
  • 2
  • Sleep Timer
  • Yes
  • Viewing Angle
  • 178
  • Smart TV Features
  • Built-in WiFi, Screen Mirroring
 

PVC Virgin Drift Eliminator Trade Information

  • Minimum Order Quantity
  • 1000 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cheque, Cash Advance (CA)
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Western Europe, Australia, Eastern Europe, Middle East, Africa, Central America, South America, Asia, North America
  • Main Domestic Market
  • All India
 

About PVC Virgin Drift Eliminator

PVC Virgin Drift Eliminator

  • COLER - BLUE
  • SIZE - 600 MM X 600 MM X 125 MM

We are one of the leading manufacturers of Drift Eliminator. The offered Drift Eliminators are widely used for preventing the undesirable loss of water to the environment, during the Cooling process.

Model Overview:

 

Space

Data

2.5

3.5

4.5

5.5

6.5

7.5

m/s

m/s

m/s

m/s

m/s

m/s

22

Resistance loss(pa)

25.40

49.60

76.30

113.60

161.30

206.60

(mm)

Water pass (g/kg)

0.90

0.13

0.16

0.23

0.27

0.35

24

Resistance loss(pa)

21.80

40.20

52.30

74.90

110.20

114.60

(mm)

Water pass (g/kg)

0.12

0.18

0.24

0.30

0.36

0.42

26

Resistance loss(pa)

20.10

32.00

50.20

74.40

102.20

141.10

(mm)

Water pass (g/kg)

0.23

0.29

0.34

0.40

0.47

0.52

28

Resistance loss(pa)

18.10

30.90

46.30

69.50

98.60

132.70

(mm)

Water pass (g/kg)

0.33

0.38

0.42

0.48

0.54

0.60

30

Resistance loss(pa)

15.40

28.10

42.90

60.40

88.50

123.00

(mm)

Water pass (g/kg)

0.43

0.49

0.55

0.61

0.68

0.74




Additional Information:

  • Item Code: ENVIROTECH
  • Production Capacity: www.envirotechindustrialproducts.co.in
  • Delivery Time: www.envirotechindustrialproduct.co.in
  • Packaging Details: www.envirotechindustrialproduct.in


Precision Multi-Blade Chevron Design

Featuring a zigzag multi-blade chevron profile, this drift eliminator is engineered for optimal airflow management. The design maximizes separation efficiency, dramatically lowering water and contaminant drift, which helps conserve water and minimize maintenance demands in cooling towers. The robust structure supports long-lasting effectiveness in demanding operational environments.


Exceptional Durability and Weather Resistance

Constructed from high-grade virgin PVC, the drift eliminator offers outstanding resistance to UV rays and corrosion. This weather-resistant material ensures longevity and reliable performance, even in areas exposed to direct sunlight and fluctuating environmental conditions. Its temperature resistance up to 60C enables consistent operation in various climates.


Simple Modular Installation and Maintenance

The drift eliminator's modular build allows for easy on-site assembly, replacement, and cleaning. Each unit is designed for swift handling, reducing downtime during installation or servicing. Its low maintenance requirement and ease of cleaning make it a practical choice for facilities prioritizing operational efficiency.

FAQ's of PVC Virgin Drift Eliminator:


Q: How does the multi-blade chevron design enhance drift eliminator efficiency?

A: The multi-blade chevron (zigzag) pattern increases the surface area and changes the direction of airflow, efficiently removing water droplets from the air stream. This design significantly reduces drift loss, helping achieve up to 0.001% water loss from circulating water flow.

Q: What are the typical applications for this PVC drift eliminator?

A: The drift eliminator is mainly used in cooling towers within power plants, industrial facilities, and HVAC systems. It serves as an accessory for evaporative cooling applications, reducing water loss, airborne contaminants, and associated noise.

Q: When should drift eliminators be replaced or maintained?

A: Drift eliminators should be inspected periodically, especially during routine cooling tower maintenance or if water drift or noise levels increase. Thanks to its modular design and low maintenance requirements, replacement or cleaning can be performed swiftly as needed.

Q: Where can these drift eliminators be installed?

A: These modules are suitable for installation in all types of evaporative cooling towers, both for new projects and as aftermarket replacements. Their modular size (600mm x 600mm x 125mm) makes them adaptable to various tower configurations.

Q: What is the process for installing and assembling the modular drift eliminator?

A: Installation is straightforward due to the modular design. The units are easily assembled and slotted into existing fixtures or frameworks. They can be quickly replaced or reconfigured, minimizing operational downtime during setup or maintenance.

Q: What are the main benefits of using a virgin PVC drift eliminator?

A: Benefits include exceptionally low water and contaminant loss, excellent UV and corrosion resistance, durability, reduced maintenance effort, easy cleaning, and improved noise control in cooling tower environments.

Q: How does using this drift eliminator contribute to noise control?

A: By efficiently managing water drift and reducing turbulence, the drift eliminator lowers the noise generated by water droplets escaping into the air, thereby enhancing the operational comfort around cooling towers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Polyvinyl Chloride Drift Eliminator Manufacturer Category

PVC And Cooling Tower Drift Eliminator

PVC And Cooling Tower Drift Eliminator

Price 350 INR

Minimum Order Quantity : 100 Pieces

Material : PVC

Dimension (L*W*H) : 600 MM X 600 MM X 125 MM

Condition : New

Application : COOLING TOWER

S Type Eliminator

S Type Eliminator

Price 350 INR

Minimum Order Quantity : 100 Pieces

Material : PVC

Dimension (L*W*H) : 600 MM X 600 MM X 125 MM Millimeter (mm)

Condition : New

Application : COOLING TOWER

PVC S Type Eliminator

PVC S Type Eliminator

Price 350 INR

Minimum Order Quantity : 100 Pieces

Material : PVC

Dimension (L*W*H) : 600 MM X 600 MM X 125 MM

Condition : New

Application : COOLING TOWER

Blue PVC Eliminator Fills

Blue PVC Eliminator Fills

Price 350 INR

Minimum Order Quantity : 1000 Pieces

Material : PVC

Dimension (L*W*H) : 600 MM X 600 MM X 125 MM Inch (in)

Condition : New

Application : COOLING TOWER