Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
| Model |
Description |
| G2201 |
Differential Pressure Gage,Range 0-1 PSI,Minor Divisions .02 |
| G2202 |
Differential Pressure Gage,Range 0-2 PSI,Minor Divisions .05 |
| G2203 |
Differential Pressure Gage,Range 0-3 PSI,Minor Divisions .10 |
| G2204 |
Differential Pressure Gage,Range 0-4 PSI,Minor Divisions .10 |
| G2205 |
Differential Pressure Gage,Range 0-5 PSI,Minor Divisions .10 |
| G2210 |
Differential Pressure Gage,Range 0-10 PSI,Minor Divisions .20,MP Option Standard |
| G2215 |
Differential Pressure Gage,Range 0-15 PSI,Minor Divisions .50,MP Option Standard |
| G2220 |
Differential Pressure Gage,Range 0-20 PSI,Minor Divisions .50,MP Option Standard |
| G2230 |
Differential Pressure Gage,Range 0-30 PSI,Minor Divisions 1.0,HP Option Standard
|
Additional Information:

Precise and Versatile Gas Pressure MonitoringGEMTECH's Mack Differential Pressure Gauge offers high-precision measurement for various gases, essential in pharmaceutical and numerous industrial processes. Its design promotes reliability and adaptability, meeting the requirements of sectors where exact pressure readings are vital for operational safety and regulatory compliance. The analog display and clear scale markings support intuitive readings in challenging environments.
Built for Industrial EnduranceConstructed with a resilient metal alloy body and featuring a protective plastic dial, this gauge is engineered to withstand tough industrial conditions. The 4-inch diameter dial face allows for high visibility, and the device's moderate weight supports secure mounting and handling. Back mounting and dual sets of NPT threaded taps facilitate flexible installation to suit different setups.
FAQ's of Pharmaceutical GEMTECH Mack Differential Pressure Gauge For Patna Bihar India:
Q: How is the GEMTECH Mack Differential Pressure Gauge installed for optimal performance in industrial settings?
A: For best results, mount the gauge using its back mount configuration, ensuring it is securely attached and level. Connect the high and low pressure lines to the corresponding 1/8" female NPT taps-pairs are provided both at the side and back for installation flexibility. Proper placement away from process vibration and strong magnetic fields enhances accuracy.
Q: What types of pressures can this gauge measure and what is its scale range?
A: This differential pressure gauge can measure gas pressure in multiple scale units including MM WC, CM, PAC, KPA, INCH, PSI, and MBAR, covering a range suitable for diverse industrial applications such as monitoring critical infrastructure in pharmaceutical plants.
Q: When should this gauge be used in pharmaceutical or allied sectors?
A: The gauge is ideal when there's a need to monitor and balance gas pressures across filters, cleanrooms, or process lines where maintaining specific pressure differentials is essential for product safety and regulatory compliance in pharmaceutical, power plant, cement, steel, fertilizer, and textile sectors.
Q: Where can this differential pressure gauge be effectively utilized?
A: It finds effective application in environments like pharmaceutical labs, cleanroom pressure monitoring, power plants, cement plants, steel plants, fertilizer and textile plants-particularly in Patna, Bihar, India. Its sturdy construction ensures longevity in high-demand settings.
Q: What is the benefit of using a differential pressure gauge with a 2% accuracy level?
A: A 2% accuracy rating ensures precise readings crucial for maintaining the required process parameters in sensitive industries, minimizing risks associated with pressure fluctuations, and supporting compliance with strict operational standards.
Q: How does the analog display enhance user interaction?
A: The 4-inch analog dial face with white/black color contrast allows for clear, quick readings, reducing operator error and improving efficiency during routine monitoring or maintenance checks.
Q: What is the recommended process for calibrating the pressure gauge?
A: Calibrate the gauge in a controlled environment at approximately 70F (21.1C) across its entire scale range, using standard pressure sources for verification. Regular recalibration ensures ongoing compliance and measurement reliability, especially for pharmaceutical applications.