About Model G2000-0-SP GEMTECH Differential Pressure Gauge Range 0-0.50 Inch W.C.

Model G2000-0-SP GEMTECH Differential Pressure Gauge Range 0-0.50 Inch W.C.
Series G2000, GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure, differential pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime, They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely. The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21140-660
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa.
MODELS & ORDERING
Range - Inches of Water
- G2000-0-Range 0-0.50" w.c.,minor divisions .01,calibrated for vertical scale position.
- G2000-00-Range 0-0.25" w.c., minor divisions .005,calibrated for vertical scale position.
- G2000-00N-Range .05-0-.2" w.c., minor divisions .005, calibrated for vertical scale position.
- G2001-Range 0-1.0" w.c., minor divisions .02.
- G2002-Range 0-2.0" w.c., minor divisions .05.
- G2003-Range 0-3.0" w.c., minor divisions .10.
- G2004-Range 0-4.0" w.c., minor divisions .10.
- G2005-Range 0-5.0" w.c., minor divisions .10.
- G2006-Range 0-6.0" w.c., minor divisions .20.
- G2008-Range 0-8.0" w.c., minor divisions .20.
- G2010-Range 0-10" w.c., minor divisions .20.
- G2015-Range 0-15" w.c., minor divisions .50.
- G2020-Range 0-20" w.c., minor divisions .50.
- G2025-Range 0-25" w.c., minor divisions .50.
- G2030-Range 0-30" w.c., minor divisions 1.0.
- G2040-Range 0-40" w.c., minor divisions 1.0.
- G2050-Range 0-50" w.c., minor divisions 1.0.
- G2060-Range 0-60" w.c., minor divisions 2.0.
- G2080-Range 0-80" w.c., minor divisions 2.0.
- G2100-Range 0-100" w.c., minor divisions 2.0.
- G2150-Range 0-150" w.c., minor divisions 5.0.
Additional Information:

Versatile Installation for Industrial ApplicationsThe GEMTECH G2000-0-SP Differential Pressure Gauge is engineered for demanding environments such as power plants, pharmaceutical manufacturing, and processing facilities. Its dual sets of high and low pressure taps (side and back) support flexible mounting for a wide range of piping and panel layouts, ensuring seamless integration into your system. Designed for gas pressure measurement, the gauge provides compatibility with numerous industrial processes.
Precision Measurement and Durable ConstructionWith an accuracy of up to 2% of full scale within its range, the gauge supports critical monitoring requirements. The combination of a metal alloy body, tough plastic dial, and a precision alloy pointer provides both resilience and dependable performance. The analog display facilitates straightforward interpretation, and the generous 4-inch (101.6 mm) dial allows for quick, clear reading of differential pressure values.
FAQ's of Model G2000-0-SP GEMTECH Differential Pressure Gauge Range 0-0.50 Inch W.C.:
Q: How do I install the GEMTECH G2000-0-SP Differential Pressure Gauge?
A: The gauge offers duplicate high and low pressure taps on both the side and back (1/8" female NPT), allowing you to mount it as per your system layout. Select either side or back taps for plumbing connections, secure the gauge using a back-mount configuration, and ensure the connections are leak-free for accurate pressure readings.
Q: What type of pressures can this gauge measure?
A: This model is designed to measure low differential pressures in the range of 0-0.50 Inch Water Column (W.C.). It can display pressure in MM WC, CM, PAC, KPA, INCH, PSI, and MBAR, making it suitable for diverse applications, particularly with gases.
Q: When should this differential pressure gauge be used?
A: The Model G2000-0-SP is ideal for applications where accurate low-pressure differential measurement is required, such as HVAC systems, filtration monitoring, and process control within pharmaceutical, power, steel, cement, fertilizer, and textile industries.
Q: Where can the GEMTECH G2000-0-SP be used?
A: It is suitable for use across a wide range of environments, including pharmaceutical labs, power plants, cement and steel factories, fertilizer manufacturing, and textile production units, wherever monitoring gas differential pressure is needed.
Q: What is the benefit of duplicate pressure taps on the gauge?
A: Having a pair of high and low pressure taps on both the side and back allows flexible installation options, making it easier to fit the gauge into different setups and facilitates easier maintenance and pressure monitoring from various positions.
Q: How accurate is this model across its measurement range?
A: This gauge offers accuracy up to 2% of full scale, with slightly varying percentages depending on the pressure range, ensuring reliable monitoring for critical processes. At standard room temperature (70F or 21.1C), performance remains consistent across the specified measurement range.