About Manometer Differential Pressure Gauge 500-0-500 MM WC

Manometer Differential Pressure Gauge 500-0-500 MM WC
Series G2000GEMTECHDifferential Pressure Gaugesare Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature- -21 140 -6 60
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure -Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections -1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing- Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand168 Hour Salt Spray Corrosion Test
- Accuracy- i2% of full span at 70???(21??????(i3% on -0, and i4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive AndNegative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH ByModel NumberPopularity
- FILTER BY
- Range -MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range0-10 MM W.C.,Minor Divisions.20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range0-300 MM W.C. |
| G2000-50MM |
DPG,Range0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range0-80 MM W.C., Minor Divisions 2.0. |
Additional Information:
- Item Code:Manometer-Differential-Pressure-Gauge-250-0-250-MM-WC
- www.envirotechindustrialproduct.in
- www.envirotechindustrialproduct.in
- www.envirotechindustrialproduct.co.in

High Accuracy for Industrial Applications
Engineered for the pharmaceutical industry, this manometer delivers accurate and consistent differential pressure readings. Its analog display provides clear visual feedback, making it suitable for installation and monitoring in cleanroom environments or process control panels. The precision manufacturing process ensures dependable results every time.
Versatile and Robust Design
Built from a strong metal alloy and finished in WHITE/Black, this gauge withstands demanding industrial use. The 4-inch dial provides readability from a distance, while the NPT 1/8-inch threaded back mount allows straightforward integration into various systems. Its standard processing type makes it compatible with a wide array of applications.
FAQ's of Manometer Differential Pressure Gauge 500-0-500 MM WC:
Q: How is the Manometer Differential Pressure Gauge installed?
A: The gauge uses a back mount setup with an NPT 1/8-inch thread, making it suitable for easy installation onto standard process panels or pipework in industrial settings.
Q: What is the primary usage of this manometer gauge?
A: It is predominantly used in pharmaceutical industries to monitor and control differential pressure, which is essential for cleanroom and process equipment compliance.
Q: When should I consider recalibrating or servicing this gauge?
A: Periodic calibration is recommended every 6-12 months depending on usage intensity to maintain measurement accuracy and ensure reliable operation.
Q: Where can this manometer be used safely?
A: It is ideal for environments requiring precise pressure monitoring, such as pharmaceutical production plants, laboratories, or any industry needing airflow and filter pressure checks.
Q: What are the benefits of the analog display on this gauge?
A: The analog display offers immediate visual feedback, making it easy for operators to detect pressure changes at a glance and take necessary actions without delay.
Q: How does the material and build support durability?
A: Constructed from robust metal alloy, the manometer is designed to withstand regular industrial use, resist corrosion, and ensure long-lasting accuracy.
Q: What process standards does this manometer meet?
A: Manufactured with standard processing and multiple scale ranges, it meets typical industry requirements and provides flexibility across different measuring units.