About Magnehelic Differential Pressure Gauges In Amritsar Industrial Area Punjab

Magnehelic Differential Pressure Gauges In Amritsar Industrial Area Punjab
Series 2000 DWYER Magnehelic Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,Resistance of Filter,Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" Female NPT Duplicate High And Low Pressure Taps - One Pair Side And One Pair Back
- Housing - Die cast aluminum case and bezel, with acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
DWYER By Model Number Popularity
- FILTER BY
- Range - Inches of Water
|
Model
|
Description
|
|
2000-0
|
Differential Pressure Gauges,Range 0-0.503 w.c., minor divisions .01, calibrated for vertical scale position.
|
|
2000-00
|
Differential Pressure Gauges,Range 0-0.253 w.c.,minor divisions .005, calibrated for vertical scale position.
|
|
2001
|
Differential Pressure Gauges,Range 0-1.03 w.c.,minor divisions .02.
|
|
2002
|
Differential Pressure Gauges,Range 0-2.03 w.c.,minor divisions .05.
|
|
2003
|
Differential Pressure Gauges,Range 0-3.03 w.c.,minor divisions .10.
|
|
2004
|
Differential Pressure Gauges,Range 0-4.03 w.c.,minor divisions .10.
|
|
2005
|
Differential Pressure Gauges,Range 0-5.03 w.c.,minor divisions .10.
|
|
2006
|
Differential Pressure Gauges,Range 0-6.03 w.c., minor divisions .20.
|
Additional Information:

Superior Accuracy and Versatile Application
Magnehelic Differential Pressure Gauges provide highly accurate readings tailored for multiple industries in Amritsar, Punjab. Their robust design ensures effective performance in Pharmaceutical, Power Plant, Cement, Steel, Fertilizer, and Textile settings. Available in classic white/black colors and constructed with a durable metal alloy, these gauges are suitable for a wide range of gas pressure measurement needs.
Engineered for Industrial Durability
With a strong metal alloy build and a plastic dial face, these gauges are designed for longevity and robust use in challenging industrial environments. Suitable for high-stress applications, every component - from the alloy pointer to the back-mount fitment - guarantees resilience against corrosion and easy readability in busy plant situations.
FAQ's of Magnehelic Differential Pressure Gauges In Amritsar Industrial Area Punjab:
Q: How are Magnehelic Differential Pressure Gauges typically used in industrial settings?
A: These gauges are primarily deployed to monitor differential gas pressures in processes across pharmaceutical, power, cement, steel, fertilizer, and textile plants, helping maintain safe and efficient operating standards.
Q: What benefits do these gauges offer for industrial applications in Amritsar?
A: Magnehelic gauges provide precise, reliable pressure readings, allowing for early detection of system imbalances or filter blockages, which helps prevent equipment malfunction and ensures operational safety.
Q: When should a Magnehelic Differential Pressure Gauge be installed or replaced?
A: It is advisable to install new gauges during system commissioning or major maintenance intervals, and to replace them when accuracy declines or physical damage is observed to ensure accurate monitoring.
Q: Where can I mount the Magnehelic gauges in my plant?
A: These gauges feature a back mounting type and can be installed on control panels or directly on process lines, utilizing the 1/8" female NPT pressure taps provided on both the side and back for maximum placement flexibility.
Q: What is the measurement range and accuracy offered by this model?
A: This Magnehelic model measures gas pressures across multiple units (MM WC, CM, PAC, KPA, INCH, PSI, MBAR) with accuracies ranging from 2% to 4% of full scale, depending on the pressure range selected, ensuring precise monitoring.
Q: How do I select the right scale range for my application?
A: Choose the scale range that aligns with your process requirements-whether in MM WC, KPA, or PSI. The flexibility in scale options makes it suitable for varied industrial applications, enhancing utility and measurement clarity.