About GEMTECH SERIES G2002-SP Differential Pressure Gauge Range 0-2 Inch W.C.

GEMTECH SERIES G2002-SP Differential Pressure Gauge Range 0-2 Inch W.C.
Series G2000, GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure,Differential Pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature - -21140-660
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa.
MODELS & ORDERING
Range - Inches of Water
- G2000-0-Range 0-0.50" w.c.,minor divisions .01,calibrated for vertical scale position.
- G2000-00-Range 0-0.25" w.c., minor divisions .005,calibrated for vertical scale position.
- G2000-00N-Range .05-0-.2" w.c., minor divisions .005, calibrated for vertical scale position.
- G2001-Range 0-1.0" w.c., minor divisions .02.
- G2002-Range 0-2.0" w.c., minor divisions .05.
- G2003-Range 0-3.0" w.c., minor divisions .10.
- G2004-Range 0-4.0" w.c., minor divisions .10.
- G2005-Range 0-5.0" w.c., minor divisions .10.
- G2006-Range 0-6.0" w.c., minor divisions .20.
- G2008-Range 0-8.0" w.c., minor divisions .20.
- G2010-Range 0-10" w.c., minor divisions .20.
- G2015-Range 0-15" w.c., minor divisions .50.
- G2020-Range 0-20" w.c., minor divisions .50.
- G2025-Range 0-25" w.c., minor divisions .50.
- G2030-Range 0-30" w.c., minor divisions 1.0.
- G2040-Range 0-40" w.c., minor divisions 1.0.
- G2050-Range 0-50" w.c., minor divisions 1.0.
- G2060-Range 0-60" w.c., minor divisions 2.0.
- G2080-Range 0-80" w.c., minor divisions 2.0.
- G2100-Range 0-100" w.c., minor divisions 2.0.
- G2150-Range 0-150" w.c., minor divisions 5.0.
Additional Information:

Precision Measurement Across IndustriesThe GEMTECH SERIES G2002-SP Differential Pressure Gauge is tailored for accurate gas pressure measurements in varied industrial environments. Its resilience and accuracy make it ideal for sectors such as pharmaceuticals, power plants, cement plants, steel manufacturing, fertilizers, and textiles. The gauge's analog display and multi-range scale options ensure operators can monitor differential pressure effortlessly and precisely, improving both process safety and efficiency.
Robust Design and Versatile InstallationBuilt from durable metal alloy with a plastic dial and alloy pointer, this gauge is designed for longevity and reliable performance. It features dual high and low pressure taps on both the side and back, providing flexible mounting options. The 1/8" female NPT threads ensure easy integration into existing systems. These features cater perfectly to the practical demands of industrial plants looking for reliability and ease of use.
FAQ's of GEMTECH SERIES G2002-SP Differential Pressure Gauge Range 0-2 Inch W.C.:
Q: How is the GEMTECH SERIES G2002-SP Differential Pressure Gauge installed?
A: The gauge is equipped with duplicate high and low pressure taps-both on the side and back-using 1/8" female NPT threads. This allows for flexible installation to suit various system configurations, ensuring a fit for multiple industrial setups.
Q: What types of pressure can this gauge measure?
A: The G2002-SP is designed to measure the differential pressure of gases. It supports multiple scale ranges, including mm WC, cm, Pa, kPa, Inch, psi, and mbar, enhancing accuracy and utility for a broad spectrum of applications.
Q: When should I use this gauge in industrial applications?
A: This differential pressure gauge is ideal when precise gas pressure monitoring is critical, such as in pharmaceuticals, power plants, cement and steel production, fertilizer processing, and textile manufacturing. It helps maintain safe and efficient system performance.
Q: Where can the GEMTECH SERIES G2002-SP be used most effectively?
A: It can be used in any scenario requiring accurate differential gas pressure measurement, particularly in industrial facilities in India and internationally, where reliability, robustness, and compliance with process standards are essential.
Q: What is the accuracy of this gauge across its full scale?
A: The standard G2002-SP model offers an accuracy of 2% of full scale at 70F (21.1C). On certain ranges, accuracies may vary between 3% and 4%, as indicated for specific pressure ranges.
Q: How does the analog display benefit users?
A: The analog display ensures quick and straightforward reading of pressure values. The clear white and black dial design, combined with the 4" face and alloy pointer, enhances visibility for fast and reliable monitoring, even in busy industrial environments.
Q: What advantages does the robust metal alloy construction provide?
A: The metal alloy body provides excellent durability, resisting mechanical wear and environmental influences. This improves long-term reliability, minimizes maintenance requirements, and ensures sustained accuracy in harsh industrial conditions.